Vacuum Circuit Breakers
Intrans manufactures VCBs as standalone type or in multi panel arrangement with future extension provision. The panel contains a draw out type circuit breaker with automatic shelters to ensure isolation from live areas. The panels are manufactured from high quality steel which is powder coated after a seven tank cleaning process to ensure long life. Safety interlocks are provided to prevent accidents.
Rated Voltage : 12 KV
Rated Current : 630-1250 Amps.
...moreResin Cast Potential Transformer
In AC circuits, for measuring large voltages a specially constructed accurate ratio Potential Transformers are used. Their function is to reduce the supply Voltage to a value small enough to be easily measured with standard low range AC instruments of moderate size and capacity. The advantages of using Potential Transformers for range extension of AC meters are many fold.
...morePower Distribution Transformer
INTRANS Transformers are made by using modern Computer Aided Design and reliable process technology. Quality Control procedures are devised and strictly adhered to ensure quality in every stages of manufacture i.e., from the very stages of raw material purchases to final delivery. The designs are chosen so that the total cost including material cost, maintenance cost and the energy cost due to no load and load losses are minimum. The designing and manufacturing operations are guided and controlled by experts in the field. All the above factors ensure that transformer coming out of Intrans’ plant is optimum designed, reliable and rugged.
...moreOutdoor metering Unit
Intrans make Outdoor metering cubilcle consists of two Current Transformers and One Potential Transformers along with Test Terminal block and Fuses enclosed in a powder coated Galvanised Iron Enclosure confirming to IP54 Standards.
...moreOutdoor Load Break Switch Panel
Intrans make outdoor load break switch panels comprise of a HV 12 kV Load break switch panel with CTPT and Test Terminal Block and HT Fuses completely enclosed in a Powder coated Galvanised Iron enclosure confirming to IP 54 Class protection. Even under adverse weather conditions the Galvanised Iron enclosure ensures a long life for the Load break switch.
...moreOil Test Set
INTRANS make Oil Test Set is used for testing dielectric strength (BDV) of transformer oil. The electrode assembly and other electrical design features are as per the requirement of IS 335IS 6792. The unit consist of a centre tap type high voltage cast resin type transformer which feeds the voltage to the liquid dielectric through the system of electrodes. To energise the high voltage transformer the inductive potentiometer is used in order to increase the voltage from low values to highest available values. The synchronous motor drives this transformer or can be decoupled. With this arrangement the unit can be motorised or manual operated. In between the primary of the HV Transformer and energizing networks a contactor and a protective circuit is incorporated as protective and controlling devices. The circuit has fast acting tripping characteristics which gives an ideal protective curve. The contactor acts as main switch and also interconnects safety devices such as door switches, control switches and other allied controls desired by customer. The output voltage is measured by square front dial instrument. The marking on the dial are Kilovolts indicating the true applied voltage. The circuit is so arranged to have memory effect to breakdown voltage which facilitates the effective operation.
Feature : Manual or motorised version is available » Compact size » Ease of operation
...moreLow Tension Current Transformers
Low Tension Current Transformers are used for measurement andor protective applications in 660V Class. In Measuring Current Transformers (Refer TABLE- 1) main concern is the accuracy of the secondary current over a wide operating range. Typically the errors are guaranteed to be within specified limits. The nature of errors are current (Ratio) error and phase displacement. Metering current transformers are specified by (1) a burden and (2) accuracy class. Protective Current transformers (Refer TABLE-II) are specified by (1) a burden (2) accuracy class and (3) accuracy limiting factor. In other words the errors of the protective current transformers at the rated full loaded current as well as at a current given by the accuracy limit factor times the full load current are specified. There exists a class of protective current transformers for special purpose application known as class PS CTs. These are mainly intended for use in applications where the required characteristics of the current transformers cannot be conveniently expressed in terms used for class 5P, 10P and 15P current transformers. The knee point voltage, exciting current and secondary winding resistance are so dependent on the protective gear involved. The manufacturers of protection gear stipulates the requirements in terms of minimum knee point voltage and maximum exciting current. The current transformers of class PS type are of low reactance type since the core is made up of jointless ring type (spirally wound toroidal type) cores and secondary turns are substantially evenly distributed along the whole length of the magnetic circuit.
...moreload break switch panel
Load break switch panel is used to Switch ONOFF the 11KV supply to the consumer. The panel is installed in indoor. This is installed in between the incoming Board supply and distribution transformer provided at the customers premises. Load Break Switch Panels are available with and without metering facilities.
...moreHT LT switchgear Oil filled Transformer
Intrans CSS consists of Oil filled Transformer with HT and LT switchgear. The transformer is of Corrugated tank type of construction and Hermetically sealed. High Tension side of the CSS consists of Load Break Switch or Vacuum Circuit Breaker as required. On the Low voltage side ACB and MCCBs are provided as per the customer specification. The Compact Sub Station is available for indoor use as well as Outdoor.
...moreCast Resin Transformer
We manufacture lower range of Cast Resin Transformers (CRT) both single as well as three phase, ranging from 16 KVA to 1000 KVA capacity. Our Cast Resin Transformers are designed effectively to reduce line cost and line losses and improve the quality and reliability of the electrical supply system. The transformers can be made suitable for direct pole mounting, indoor application, hazardous area application etc. These are capable of withstanding mechanical and thermal stresses caused by short circuiting in accordance with Bureau of Indian Standards Specification 11171
...moreResin Cast Current Transformers
Resin Cast current Transformers are dry type transformers the active part of which is completely embedded in quartz loaded epoxy resin by using Vacuum moulding technique. After moulding the resin is hardened by polymerisation. The main insulation between primary and secondary and earth is obtained by this epoxy resin and hence CTs have a lot of technical advantages.
...moreIndoor Load Break Switch Panel
33KV PT Metering Sets
unitized substation
Oil Filled Transformer
Epoxy Resin Casting