Bulk Water Meter
Get Price Quote
For measurement of high flows of cold water. Dry-dial. Low pressure loss. Measuring accuracy conform to ISO 4064 Standard, accuracy class 2. The meter can be installed in horizontal, vertical or inclined position (a horizontal position with the register face upwards is recommended). Working conditions: Maximum water temperature: 30ºC. Maximum working pressure: 16 bar. ANSI flanges ends connection. Pulse output equipped.
Level Transmitters
Get Price Quote
We present highly reliable Level Transmitters to our reputed clients. A study of transmission line theory is required to prove this phenomenon. An equivalent circuit for the coated section is shown as a ladder network producing the phase shifted error signal. One way to cancel the error signal is to measure the conductive component (c) shown in Figure 3 Method A. Since the 45o relationship exists, the capacitive error component (e) is the same magnitude and can be subtracted from the total output signal, thus effectively canceling the error signal. Another cancellation method use is to introduce a 45º phase shift to the entire measurement as shown in Figure 3, Method B. This automatically cancels the coating error portion because the conductance component (c) still has the same magnitude as the error component (e), resulting in the appropriate level signal. For Continues Level & Volume Measurement Of All Liquids, Slurries & Powders : Electronic cancellation of conductive coating on probesSpecially designed to use with strong acids & alkalis Fully insulated probe for conductive liquids No maintenance & probe cleaning v250 khz. Operation Factory calibrated transmitter4 –20 ma , 3wire10 – 32 v dc power supplyProgrammable display & control unit with bar graphUp to 4 change over contact output (h, l, hh &ll)Volume, level & percentage display Suitable For : All acidsAlkalis & chemical solvents milkBeveragesPowders latex & paintsWater, diesel & edible & non edible oils effluents Basic Measurement Principle : A capacitor is formed when a level-sensing electrode is installed in a vessel. The metal rod of the electrode acts as one plate of the capacitor and the tank wall (or reference electrode in a non-metallic vessel) acts as the other plate. As the level of the material being measured rises, the air or gas normally surrounding the electrode is displaced by the material's different dielectric constant. The value of the capacitor changes because the dielectric between the two plates has changed. RF capacitance instruments detect this change and convert it into a relay actuation or proportional output signal. The following equation illustrates the capacitance relationship: C = 0.225 K (A+D) Where : C = Capacitance in pico farads K = Dielectric Constant of material A = Area of plates in square inches D = Distance between the plates in inches The dielectric constant is a numerical value between 1 and 100 that relates to the ability of the dielectric (material measured between the plates) to store an electrostatic charge. The dielectric constant of a material is determined in an actual test cell. In actual practice, capacitance change is produced in different ways depending on the material being measured and the level electrode being used. However, the basic principle always applies. If a higher dielectric material replaces a lower one, the total capacitance output of the system will increase. If the electrode is made larger (effectively increasing the surface area) the capacitance output increases; if the distance between measuring electrode and reference decreases, then the capacitance output increases. Non-Conductive Materials : The capacitance changes as material comes between the plates of the capacitor. For example, suppose the sensor and the metal walls are measuring the increasing level of a non-conductive material such as oil. Figure 1 depicts a typical system. While the actual capacitive equation is very complex, it can be approximated for the above example as follows : C = 0.225 (K air x A air) + 0.225 (K material x A material)Dair Dmaterial Since the electrode and tank wall are fixed in place, the distance between them will not vary. Similarly, the dielectric of air (1) and the measured material, oil (3.1), also remain constant. Therefore, the capacitance output of the system example can be reduced to this very basic equation: C = (1 x A air) + (3.1 x A material) As this equation demonstrates, the more material in the tank, the higher the capacitance output will be. The capacitance is directly proportional to the level of the measured material. Conductive Materials : The same logic for nonconductive materials applies to conductive materials, except that conductive material acts as the ground plate of the capacitor rather than the tank wall. This changes the distance aspect of the equation, whereby the output would be comparatively higher than for a nonconductive material. However, it still remains fixed; therefore, as level rises on the vertically mounted sensor, the output increases proportionately. A material is considered conductive when it has a conductivity value of greater than 10 micro Siemens /cm. The level-sensing electrode must be insulated. A non insulated sensor is tip sensitive and acts like a conductive switch. Material Buildup : The most devastating effect on the accuracy of RF capacitive measurements is caused by the buildup of conductive material on the electrode surface. Non-conductive buildup is not as serious since it only represents a small part of the total capacitance. The Level Probe : The probe used in this device is a stainless steel rod, fully insulated with HDPE/PTFE which does not make any direct contact with the medium. The capacitance formed by the probe rod and the conductive material is proportional to the level of material in the tank (ie), as the level increases the capacitance also increases. The Transmitter : A crystal controlled radio frequency sine wave of fixed peak voltage is passed through the capacitance formed by the tank body and the probe in series with a known capacitance. The voltage drop across the fixed capacitor will be 90º out of phase with the applied wave form and is proportional to the tank capacitance. Compensating For Conductive Material Buildup : Coating error is illustrated by the diagram shown in Figure 2. The submerged portion of the electrode generates nearly a pure capacitive susceptance. Since the electrode is insulated, a conductive component is virtually non-existent. However, the upper section of the electrode, coated with conductive material, generates an error signal consisting of a capacitive susceptance and a conductive component. The result is an admittance component that is 45º out of phase with the main level signal. Specifications Transmitter & Probe Principle of OperationRF Capacitance/AdmittanceProbe Fully Insulated (HDPE/PTFE)SS rod/Coaxial ProbeProbe LengthAs per the tank heightEnclosure NylonCompensation for moistureProvidedEnclosure ProtectionWeather proof- IP65Wetted PartsSS 316/ HDPE/PTFEProcess ConnectionFlanged /screwedFlange StandardANSIFlange Size & Rating1 ½" 150 lb.Mounting Silo TopElectrical Connection¾" E.TPower Supply 10 to32 V,DC(or from display unit)Cable Type & Size3core x 0.75 sq.mm screened PVC cableOutput 4 - 20 mADimensions 65 mm () x 100mm (H) Control & Display Unit (Micro Controller Based) Power Supply220V, AC,50 Hz./ 24V,DCPower Consumption< 10 Watts.Sensitivity AdjustmentProvidedEnclosure WeatherproofMounting Wall mounted / Panel MountedAlarms Upper & Lower limit,230V,5A change over contactsDisplay 5 Digit LED Display /4Digit LED +20segment BargraphCalibration Field Calibration FacilityAccuracy 0.01% of FSResolution 1/65000Dimensions 92mm x92mm x110mm /48mm x 92mm x110mm
Best Deals from Measuring Instruments
Auto Refractometer
Get Price Quote
We are offering auto refractometer. Model – tomey rc 800  simple & speedy measurement  diameter measurement of cornea and pupil  high speed printer  auto shot  colour touch screen from tomey corporation, japan
Water Level Indicator
Get Price Quote
The Water Level Sensing Section senses the level of water in the tank and sends it (wireless) to the Receiver Section. Receiver Section is connected to the Controlling Section, which process the received information and produces visual, sound indications and controls the operation of the motor whenever required.
Magnetostrictive Level Transmitter
80,000 Per Piece
Digital Ph Meter
Get Price Quote
Humidity Meters
Get Price Quote
Humidity Meters, Temperature Indicators, Temperature Controller
round pvc rpm analog meter
Get Price Quote
round pvc rpm analog meter
Currency Counting Machine
Get Price Quote
Currency Counting Machine, Agro Products
Electrical Instruments
Get Price Quote
Electrical Instruments, Scientific Instruments, Lab Chemicals
electrical measuring instrument
Get Price Quote
electrical measuring instrument
electrical indicators
Get Price Quote
electrical indicators, Transformer Accessories, Electrical Connectors
Water Meters
Get Price Quote
Water Meters, mechanical automobiles, taxi fare meters, Speedometers
contact angle meter
Get Price Quote
contact angle meter, hot chamber Dip Coating Unit, Laser Raman Spectrometer
Multi Jet Type Water Flow Meter
Get Price Quote
Multi Jet Type Water Flow Meter
Digital Ph Meters
Get Price Quote
Digital Ph Meters, Lab Chemicals, Silica Gel, lab instruments
moisture indicator
Get Price Quote
moisture indicator, Direct Coupled Actuators, Solenoid Valves