Neutral Grounding Panel
Get Price Quote
1 Unit (MOQ)
Neutral Grounding Resistor
Get Price Quote
10 Piece (MOQ)
INDUSTRIES SYNDICATE’ make NGRs are rated upto 33KV.Single line to ground faults are tripped off immediately.This is one of the widely used form of system grounding. Usually neutral of substation transformer upto 33kv is grounded through a resistor called neutral gounding reistor. Ohmic values are so selected as to relieve the system of destructive transient voltages.
Best Deals from Neutral Grounding Resistors
Punched Grid Type NGR
Get Price Quote
With that aid of technologically updated infrastructure and a team of diligent professionals, we are involved in manufacturing, supplying and exporting Punched Grid Type NGR. These resistors are applauded by our clients world wide for their easy installation, dimensional accuracy, safe usage, excellent protection and durability. The qualitative Punched Grid Type NGR is one of the most reliable sources for saving the whole electronic system from failure and collapse. Our expert team of manufactures a spectrum of precision engineered products of Punched Grid Type NGR. We offer a gamut of designed products with high performance, latest technology, reliable and durability. Along with superior products quality, the company is preferred for its efficient post-sales services. The service engineers provide required services within committed time period for the products. Features: Grids are punched out of AISI 304 / AISI 430 type stainless steel sheets or AISI - 406 i.e. FeCrAl Sheets. Temperature coefficient resistance is 0.094% per degree C for stainless steel AISI -304 & 0.15% per C for FeCrAI i.e. AISI -406 Connection between the adjacent grids can be of following type :- (A)Adjacent grids will be connected by using galvanized Nut-Bolts using spring washers. (B) With Tig welded joints, which are totally secured against intense vibration. Terminals can be brought down at the bottom for ease of connection if asked. Each grid element is supported on Tie rods. Hence the assembly of resistance unit becomes very sturdy and it can absorb intense vibrations. Grids are insulated from M.S. tie rod by using Mica tube. Galvanised / Aluminium pipe / MS Washers will be provided as spacer between grid elements and the same will be insulated from grids by using Mica washers. These grids have wide range of current rating varying from 10 Amps to 200 Amps. of breakage of epoxy link at site.
Neutral Grounding Resistors
25,000 - 500,000 Per Piece
1 Piece (MOQ)
Neutral Earthing Reactor
500,000 Per Piece
Neutral Grounding Resistors
Get Price Quote
Neutral Grounding Resistors are used to protect power transformers, power generators and other associated equipment in your power systems against 50/60 Hz faults (short circuit) and transient phenomena (lightning).SPECIFICATIONSThere are three parameters needed to specify the neutral grounding resistor.1. Rated voltage line to neutral or system voltage2. Rated fault current.3. Rated “time on” of the line to neutral voltage not exceeding the allowable temperature rise.
Neutral Grounding Resistors
120,000 Per Piece
1 Piece(s) (MOQ)
Ampcontrol is best manufacture and export company product range is NGR Panel,NIS Panel, LAVT Panel,Load Bank, Dynamic Breaking Resistor
Neutral Grounding Reactors
Get Price Quote
Neutral Grounding Reactors (NGRs) are used to control single line to ground faults only. NGR are particularly used at transmission voltage levels, when autotransformers with a delta tertiary are employed. Neutral Grounding Reactors (NGRs), normally installed between the transformer or generator neutral and ground, are effective in controlling single line to ground faults since, in general, the system short circuit impedance is largely reactive. NGRs reduce short circuit stresses on station transformers the most prevalent type of fault in an electrical system.
Neutral Grounding Resistors
5,000 - 10,000 Per piece
We offer the Power+N range of Neutral Grounding Resistor. Ngr’s are used to connect the neutral phase and the earth to limit the earth fault current to a safe value thereby protecting the transformer, generator system. The Typical operation conditions are A No Earth Fault: Continuous current (5 % to 10 % of full load current) may pass through the resistor due to system unbalance or Earth Fault Condition where restricted fault current passes through the resistor protecting the system till automatic protection takes place. Power+N Neutral Grounding Resistor Panels upto 66 kV: Purpose: Neutral Grounding Resistor is connected between the neutral & the earth so that it will limit the earth fault current to a safe value [Normally full load current of the generator, transformer, etc. thereby protecting the transformer, generator system]. Typical Operation Conditions: No Earth Fault: Continuous current (5 % to 10 % of full load current) may pass through the resistor due to system unbalance. Earth Fault Condition: Restricted fault current passes through the resistor protecting the system till automatic protection takes place. The earth pressure (Rated Voltage) is absorbed by the resistor protecting the winding etc. Salient Design features: Enclosure: For outdoors application enclosure designed to give degree of protection of IP 33 is normally used. Enclosure upto IP 65 protection are offered. Enclosure material can be Mild Steel, Aluminium or Stainless Steel. Painting / Galvanizing or Hot Dip Galvanizing or Powder Coating is offered as per requirement. Safety screen enclosure is provided if required. For continuous rating enclosure protection is not above IP 43. Material of Resistor Element: A Neutral Grounding Resistor is a very simple yet technical equipment that is an absolute requirement depending on the design of the installation. Our NGR panels are fitted with resistor elements made from stainless steel or cast iron or CU-NI or NI-CR or any other resistance material as per requirement. From our experience, formed stainless steel elements are best and economical for NGRS. Construction: NGR include resistor assembly, plus required insulators, internal connections and hardware. Options/Accesories: Few of the following are usually incorporated. Current Transformers, Potentials Transformers, Grounding Transformers, Two bushing, Elevating Stands, Manual/ Electrical operated/ Motorized Isolator, Earth Leakage Relay, Lightning Arrestors, Auxiliary Control Wiring Terminal Box with Cable Glands, Termination Kit, Stand Off Insulator, Space Heater with Thermostat Control are also offered. Cabling/ Termination: Suitable arrangement is provided for termination of cable, flats or bus duct as per requirement. Incase of XLPE cable terminal box with suitable clearance and undrilled removable gland plate is provided. Typical Specifications: Rated Voltage: In an NGR this voltage means value of line to neutral voltage (ie System Voltage divided by 1.732)Rated Current: This is the value of initial current that will flow through resistor when it is cold. Normally rated current value is same as full load current. Duty rating or Time Rating: Also referred to as Duty rating, is length of time for which NGR must withstand rated voltage. Short Time Rating: This is dependent on the design parameters of the protection system, normally it is 10 or 30 or 60 seconds. When a fault is immediately cleared and system made healthy then chances of fault repetition should be considered. 30 sec is the typical rating recomemded b y IS-304.
Neutral Grounding Resistor
Get Price Quote
We manufacture neutral grounding resistor (NGR) as per customer's specifications & requirements . NGRS are used in ac distribution networks to restrict earth fault current to a predetermined level. Resistance grounding of transformer or generator neutral star point is the most effective and preferred method.
Neutral Grounding Resistor
Get Price Quote
Neutral Grounding Resistors
50,000 - 500,000 Per Piece
1 Piece (MOQ)
Neutral Grounding Resistor
Get Price Quote
NGR / NER is used to ground the neutral of Transformer / Generator to limit prospective ground fault current to a predetermined safe value. The NGR avoids transient over voltage and gives system stability under fault conditions. Technical specification : Range : 230 V to 66 kV / 8000A Degree of protection : IP00 to IP65 Service : Indoor / Outdoor / Suitable for Highly polluting and corrosive atmosphere Enclosure Finishing : Epoxy powder coat painted / Galvanized / Stainless steel (AISI 304 / 316) Mounting type : Floor / Steel Structure Mounted Duration : 5/10/15/30/60 Sec or Continuous Frequency : 50 / 60 Hz Standard followed : IEEE - 32 Termination : Through outdoor porcelain bushing/ cable box Types of elements used : Stamped plates / Wire wound / Frame wound / Cast Iron / Edge wound Resistive elements : Stainless steel (Cr – Ni) / Cr – Al alloy (AISI 416) Optional accessories : CT / Monitoring Relay / Protection Relay / Space heaters / Vacuum contactor / Disconnector (Motorized/Manual) for Isolation or Changeover/ Zig zag Transformers Generator Protection : Single or multiple Generators with Interlock / High resistance Grounding / Through Neutral Grounding Transformers / Disconnector or vacuum contactor Up to 11 kV Maximum Temperature : 790°C Ambient Temperature : 55°C
Neutral Grounding Resistors
Get Price Quote
features : neutral grounding resistors are used in star connected systems to protect the transformer / alternator from severe damage caused in event of an earth fault. we manufacture neutral grounding resistors for all current ratings upto 3000a and for a voltage range from 230v to 36kv. the resistors can be designed in cast iron grid, rod formed grid, wire wound and punched grid form. advantages of using a neutral grounding resistor: • reduced operation and • maintenance expenses. • fast isolation of the original fault. • reduced transient over voltages. • reduced physical damage on the • equipment at fault. • simplification of ground fault location. • increased life and protection of • transformers, generators and • related equipment. • reduced frequency of faults. • improved service reliability. • increased protection in the use of lightning arresters. • increased safety for personnel.
Neutral Grounding Resistor
250,000 Per Piece
02 Piece (MOQ)
Neutral Grounding Resistor
Get Price Quote
NEUTRAL GROUNDING RESISTOR (NGR) is used for the resistance grounding of Power Systems. Earthing through Resistor is the most common, economical and effective solution for impedance earthing. It is used, when the Neutral of the supply transformer is available and its own impedance is not enough to limit the fault current. Inserting a Resistor between the Neutral of the Generator/Transformer and Ground serves to limit the maximum Fault Current to a predetermined value. This value is low enough to prevent damaging Fault Currents to the generating, distribution and other associated equipments; yet high enough to operate fault clearing relays.
NEUTRAL EARTHING/ NEUTRAL GROUNDING RESISTORS
Get Price Quote
Neutral Grounding Resistors SS304 or NiCr or FeCrAl elements Custom built Please contact KWK for a solution Neutral Grounding Resistors or Neutral Earthing Resistors(NERs) are typically used to earth power systems by adding a suitable resistor between the system neutral and earth. This brings down the possible ground-fault current to a more desirable level for mesurement and further action.
Neutral Grounding Reactors
Get Price Quote
Neutral Grounding Reactors (NGRs) are used to control single line to ground faults only. NGR are particularly used at transmission voltage levels, when autotransformers with a delta tertiary are employed. Neutral Grounding Reactors (NGRs), normally installed between the transformer or generator neutral and ground, are effective in controlling single line to ground faults since, in general, the system short circuit impedance is largely reactive. NGRs reduce short circuit stresses on station transformers the most prevalent type of fault in an electrical system. We have supplied 145KV neutral grounding reactors for 6 X 660MW at Lalitpur Thermal Power Projects through BIDCO & L&T for 220 KV, 765 KV switchyard installation. We have recently installed 145 KV Dry Type neutral grounding reactors at a power grid substation
Neutral Grounding Transformer Resistor Panels
Get Price Quote
NGTR Panel Cubicle encloses Neutral Grounding Transformer (NGT) and Neutral Grounding Resistor (NGR) for grounding earthing of Neutral current during unbalanced three phase load of the generator. This is essentially required for protection of the generator. Neutral Grounding Transformer (NGT) steps down the voltage of neutral bus from 6.6 KV 11 KV 15.75 KV level to 110 Volt or 220 Volt level. This stepped down voltage is connected to a netral grounding resistance and a ground earth terminal fro bringing the voltage level of neutral bus as close as possible to zero voltage level
Neutral Grounding Resistors
Get Price Quote
The Neutral Grounding Resistors are generally employed in the LV and MV distribution networks to protect power transformers and generators from damaging currents in the event of earth fault. This protection system represents the best choice in terms of fast response to localize the fault and consequently to reduce and prevent the overheating and mechanical stress on the conductors. Alternative protection systems like insulated neutral or direct earthing neutral have several and significant disadvantages such as dangerous transient over-voltages and high difficulties to localize the ground fault in the insulated systems or damaging fault currents with possible arc blast in the earthing neutral systems. By inserting the Neutral Grounding Resistors with appropriate characteristics between the neutral point of the transformer and the ground it is possible to limit the ground fault current for a short time to allow a quick localization of the fault but, at the same time, it does not damage the equipments.
Neutral Grounding Resistors
Get Price Quote
Neutral Grounding Resistors, Panels With Series Reactors
Neutral Grounding Resistors
140,000 - 320,000 Per set
1 set (MOQ)
Neutral Grounding Resistors, NEUTRAL ISOLATION PANEL
Neutral Grounding Resistors
Get Price Quote
Neutral Grounding Resistors, Resistance Boxes, edge wound grid resistors
Neutral Grounding Resistor
Get Price Quote
Neutral Grounding Resistor, Resistors, power resistors, load resistors
Neutral Grounding Resistors
Get Price Quote
Neutral Grounding Resistors, ABB Soft Starters, Dynamic Braking Resistors
Neutral Grounding Resistor
Get Price Quote
Neutral grounding resistor is used to avoid damages and disturbances due to the ground faults. This also produces a value that is sufficiently low to prevent damaging fault currents to the power generation, distribution and other associated equipment.
Neutral Grounding Resistors
Get Price Quote
Neutral Grounding Resistors, LT Switchboards / Panels
Neutral Grounding Resistors
Get Price Quote
Neutral Grounding Resistors, Right Angle Adapters, Electrical Instruments
Neutral Grounding Resistors
Get Price Quote
Neutral Grounding Resistors, Motor Starting And Control Resistors
Neutral Grounding Resistors
Get Price Quote
Neutral Grounding Resistors, wire wound industrial resistors, Rheostats