Automatic Ac Voltage Stabilizer
Get Price Quote
We offer Automatic Ac Voltage Stabilizer. JINDAL'S Automatic Voltage Controllers are Designed to reduce the failure rate of your equipment, optimize the use of power & save energy. Our equipments are suitable for any kind of heavy - duty, industrial load. BENEFITS : 1. Up to 80% reduction in failure rate of electrical equipment. 2. Energy saving up to 10% (up to 30% on lighting load) 3. Reduction in MDI 4. Improvement in Power Factor 5. Uniform quality of end product 6. Improve productivity of the plant PAY-BACK PERIOD : Owing to its high efficiency & associated benefits, the pay-back period for the cost of JINDAL'S stabilizers is generally between 6-12 months and it saves you significant costs in subsequent years through its life. SPECIFICATIONS : 1. Input Voltage (Volts) : 350-450V, 340-460V, 330-470V, 320-480V, 300-500V 2. Efficiency (Approx) : >99.5%, >98.7%, ~98.7%, ~98.5%, >98% 3. Output Voltage : 400V +-1%, 3-Phase, 50Hz 4. Cooling : Natural Oil Cooled (up to 5000kVA) Air Cooled (up to 4000kVA) 5. Type : Indoor Outdoor 6. Temperature Rise (Max.) : Designed for 30-35 Deg C above ambient as on top of Oil full load (Against IEC Standard of 45 Deg C) 7. Mounting : Uni-directional Wheels 8. Correction rate : 6-15VSecond (up to 500kVA) and 3-6Vseconds (above 500kVA) 9. Wave Form Distortion : Virtually Nil 10. Duty Cycle : 100% Continuous 11. Reference Standard : IEC 60076
L.t. Automatic Voltage Stabilizer
Get Price Quote
We are offering L.t. Automatic Voltage Stabilizer. Inspite of best efforts, no state electricity board can ensure constant voltage to the customer because of long and inadequate distribution lines and irregular load pattern on distribution transformers. Generally Voltage is low during day time and high during night hours. Moreover on holidays, peak hours, rainy days and when agricultural and Industrial load is switched off, the voltage rises sharply which is more dangerous. This higher current affects the electrical motors (particularly smaller capacity motors upto 7.5 H.P.) in three ways: Higher current produces higher losses in electrical motors which causes premature failure of winding. These higher losses of electric motors also increase the losses of cables, switches, transformers and other associated equipments. For smooth continuous operation of motors, over load relays are usually set at 20% higher setting. With the installation of the stabilizer and maintaining 390400 volts, the motor will operate smoothly drawing 15 - 20% lesser current and correspondingly the relay setting can be reduced by 15 - 20%. In case single phasing occurs, the relay will trip in 40 - 50 seconds. The motors can withstand the high current for this period and will be safe. Also, the relays, contactors, switchgears, etc. Incorporated with the motor will be safe. L.T. AVR being easy to handle are installed in all the running units, units having L.T. Connections, units having small H.T. Connections. These can be manufactured for Balance Input Voltage and Unbalanced load or Unbalanced Voltage and unbalanced load. The units are designed for Standard Input Voltage Ranges as under Input Voltage 360-450V 350-460V 340-460V 320-460V 300-460V Efficiency (as calculated) 99.60% 99.50% 99.35% 99.00% 98.70% Output Voltage 400V_+ 1% 3 Phase, 50hz Temperature Rise (Max.) Naturally Oil Cooled Mounting On Uni-directional Wheel Wave form distortion Nil Duty Cycle 100% Continuous Technical Advantages Low Replacement Cost Undistorted output characteristics ie. No wave from distortion Moving parts on L.T. Side and it’s mass is extremely low, only few Ib-inch torque Energy savings High efficiency (about 99%) and minimum no-load losses ± Simplicity and Flexibility of design On load stepless Voltage variation Long service life Regulating coils are wound with rectangular conductors on their edge, thus giving high mechanical strength compared to other designs Applications of Voltage Regulators Pharmaceutical Units Cold Storages Rolling Mills Textile Mills Paper Mills Tube Mills Rice Shellers Rubber Industries Food Processing Units Oil & Vanaspati Plants Footwear & Leather Units Tea Gardens Distilleries & Beverages Hospitals & Nursing Home Clubs Hotels High Rise Buildings Furnace Transformers Test Rooms Glass Industries Research Stations Chemical Industries The table below compares the behaviour of 5 H.P. Motor at different voltage :- INPUTVOLTAGE CURRENT KVA PF 400 7.5 A 5.2 0.8 425 11% More 18% More 0.7 435 19% More 28% More 0.61 445 265 more 38% More 0.57 The table below compares the behaviour of 60 watt lamp at different voltage :- VOLTAGE CURRENT WATTS LUMINOUSINTENSITY LIFE IN HOURS 230 0.26 60 W 710 1000 240 0.27 65 W-8.3% More 820 575 250 0.28 70.6-17.6% More 943 338 260 0.29 75.4-25.6% More 1073 200 270 0.31 83.4-39% More 1213 100
Best Deals from Automatic Voltage Stabilizer
Ht Automatic Voltage Stabilizer
Get Price Quote
Recons Power Equipments is Manufacturer, Exporter & Supplier of HT Automatic Voltage Stabilizers, Auto Wound Transformers having helical coils mounted on a conventional laminated core. Carbon Rollers assembled on a fiber glass carrier board traverse the length of the Coil Track. These rollers are electrically connected to the output terminals and as they are driven over the track, a variable voltage is obtained. Beneath the regulating coil a number of compensating winding are connected in parallel and short circuited to reduce the effect of core-flux ‘fringing’ and keeps the reactance of the regulator fairly constant at any position of the rolling contact. The variations of more than ± 1% of the rated output voltage of the stabilizers are sensed through solid state relay which send signals to the controlling servo motor which further drives the roller mechanism in such a direction so as to increase or decrease the voltage and stabilize it to the rated output voltage. Solid State Relay operates on 230 V, 1Ø supply. H.T. Automatic Voltage Stabilizers are used to get stable input voltage for individual Distribution Transformer, irrespective of High / Low Voltage being received from Electricity Authority. These are installed on the input side of the Transformers. It also prevents the Transformer from getting overloaded. RECON’S H.T. Automatic Voltage Stabilizer takes care of wide voltage variation ranges, sleeplessly and in ON LOAD condition, leading to full load utilization of the Transformer, installed. RECON’S H.T. Stabilizer Comprises of : Step down unit double wound.Buck Boost Unit double wound.Stabilizer unit auto wound delta connected with rolling contacts capable of moving on the winding through Automatic / Motorized / Manual mechanism for regulation of the voltage at the output side.Control Unit. Built as per Customer’s Specifications. Why Recon’s Stabilizers Should Be Installed : Energy saving between 5% to 10%.High efficiency (above 98%) & minimum load losses.On Load stepless voltage variation.Increase in the productivity by reducing the breakdown period of the machines.Constant Voltage throughout the plant causing reduction in maintenance cost of the equipment.Low replacement cost.Long Service life.80% Depreciation claim as per Income Tax Act. Applications : RECON’S Automatic Voltage Stabilizer play efficient role in all types of Resistive, Inductive & Capacitive loads, like Resistance Heating, Lighting Equipments, Motors, Rectifier Loads etc. It can be installed anywhere, may it be an Industrial Plant, Hospital, Hotel, Shopping Mall, Residential Colony / Complex, etc.
Air Cooled Automatic Voltage Stabilizer
Get Price Quote
Specification: Input- 100v-280vrn Output- 220+-9% Range- 0.5kVA to 10KVA Features: Precisely designedrn Minimum maintenancern High functionality
Reliable LT Automatic Voltage Stabilizer
60,000 Per Piece
Automatic Voltage Stabilizer
Get Price Quote
Automatic Voltage Stabilizers
Get Price Quote
Automatic Voltage Stabilizers, Auto Transformers
Automatic Voltage Stabilizer
Get Price Quote
Industrial Transformer, Inverter, Ups
L.T. Automatic Three Phase Stabilizer
Get Price Quote
L.T. Automatic Three Phase Stabilizer, Voltage Stabilizer