Wavelength Response/ IPCE/IQE/EQE
For measurements of relative and absolute spectral response resp. quantum efficiency of solar cells. Spectral range 300 nm —3000 nm (or as desired), cell size up to 4 x 4 cm2 . Specialised bias light adapters for tandem cells or concentrator cells available,For the determination of solar cell parameters, such as diffusion length, recombination velocity, thin film spectral transmission and others,For determination of spectral mismatch factors for subsequent calibration of cells in solar simulators (simulator lamp spectrum and reference cell SR required).
...moreUV-VIS-Fibre Optics Spectrometer
The Flame spectrometer is built using industry-leading manufacturing techniques that help deliver high thermal stability and low unit to unit variation � without compromising the flexibility and configurability that are the hallmark of Ocean Optics miniature spectrometers. New features such as interchangeable slits, indicator LEDs and simple device connectors deliver more freedom and less frustration. Whether you are an educator looking for an instrument to teach students the basic principles of spectroscopy, a research lab looking to make a breakthrough, or an engineer working to integrate a spectrometer into an OEM system, the Flame will provide you with the performance and features you need to make your UV-Vis spectroscopy application successful.
...moreThin Film Measurement System
Simultaneous ReflectanceTransmittance Measurements for Thin-Film Applications The F10-RT requires only a mouse-click to capture both reflectance and transmittance spectra by eliminating timeconsuming changes in hardware configuration. Data capture is fast – the array-based spectrometers typically take less than a second. The Analysis Advantage The F10-RT brings the power of Filmetrics analysis to simultaneous reflectance and transmittance measurements. A click of the mouse instantly reports minimum and maximum reflectance and transmittance values in user-configurable wavelength ranges. Color analysis is standard and can be displayed in common color-space systems (e.g. CIELAB and CIEXYZ) as well as visually. Measured spectra and other data can easily be printed and exported or can be saved in JPEG image format for easy distribution. Optional film thickness and index solving modules give the F10-RT all of the advanced multi-film analytical power of the Filmetrics F20. All in a Robust, Reliable Package The F10-RT arrives complete with reference standards. Its small footprint and USB connectivity ensure effortless setup. With no moving parts, no maintenance other than lamp replacement is necessary and high reliability is guaranteed.
...moreThermal hydrogen cracker
The new H-flux Atomic Hydrogen Source* works by thermally dissociating hydrogen in an electron bombardment heated fine tungsten capillary (thermal hydrogen cracker). By bouncing along the hot walls the molecular hydrogen is cracked to atomic hydrogen. This is e.g. very useful for in-situ, damage free cleaning of residual oxygen prior to sample coating or analysis. Other applications are in surface modifications appreciating the high reactivity of atomic species. The H-flux Atomic Hydrogen Source is UHV compatible and mounted on a NW35CF (2.75"OD) flange, making the source an easy retrofit to existing vacuum systems.
...moreThe Fuel Cell Test Stations
The Fuel Cell Test Stations provides control of flow, temperature and pressure for the anode and cathode gases. The station incorporates a DC electronic load. The Station also includes two humidity bottles, an Operating Manual and a computer utilizing LabView-based software. The software is designed to gather and plot data for the I-V curves, life-cycle tests, and read a reference electrode. An optional AC-Impedance measurement system is available for applications requiring more than just DC testing.
...moreTable Top Module
During the flash plateau, an electronic load scans the IV characteristic. Special option for high capacity modules, dark measurements or outdoor measurements Measurement period ca. 10-80 ms (adjustable for high capacity modules) Correction of data with respect to module temperature, irradiance. Target conditions STC or other desired test conditions
...moreSurface Area Analyzer Tester
Particle Surface Area Analyzer The AcornTMArea is a revolutionary instrument designed to measure the surface area of particles or droplets dispersed in any type of liquid. This new generation (patented) technique is based on nuclear magnetic resonance (NMR) and offers many advantages in comparison with conventional first generation surface area instrumentation. Measurements with the Acorn Area are simple and easy. Suspensions and emulsions can be measured non-invasively, without dilution. One ml of the dispersion is placed in a glass vial and then inserted into the sample chamber. The test sequence is initiated with a key stroke and within minutes, the proprietary AreaQuantTM software algorithm reports the total measured surface area.
...moresolar simulator
Photo Emission Tech., Inc manufactures and markets steady-state solar simulators that simulate natural sun light in a variety of conditions, such as those in space or at sea level. These solar simulators, also called sun simulators, provide excellent price performance. The solar simulators can be used both in laboratory or production environment. The solar simulators can be used for checking light-sensitive devices such as Solar (Photovoltaic) cell performance. Photo Emission Tech., Inc., manufactures and markets solar simulation systems that meet ASTM E927 (Japanese Standard JIS C8912 and European Standard IEC 60904-9) Class A and Class B requirements. These systems can be used for checking Photovoltaic Cell Performance and in any other application where the effect of exposure to sun light needs to studied, such as photochemistry photobiology testing and environmental exposure testing. Five standard systems are available for each class. Systems can be manufactured with three different air mass (AM) filters: AM0, AM1 and AM1.5.
...moresolar module tester
Measures IV characteristics of PV modules�maximum power, open circuit voltage, short circuit current�at standard test conditions (STC, IEC standard 60904-1),Simulated sunlight spectrally filtered to AM 1,5 global, using Xenon flashlamps, intensity adjustable,Suited for laboratory measurements and integration into production lines Temporal stability and spectrum at STC class A. Spatial uniformity +- 2-3%
...moreelectron microscope
COXEM is a provider of superb solution in electron microscope with an extensive know-how in nano-metrology. COXEM as the global nanometrology solution provider will supply the great tool to nano technologies industry through the creative innovation Features : The CX-200 SEM is a use full for surface characterization and produces high quality images with 3.0 nm resolution at accelerating voltage, 30kv and working distance, 5mm. It’s magnification is 10X to max. 300,000 X. The CX-200 is an indispensable tool for various application areas in surface analysis. You can get the great images due to its long depth of focus. The CX-200 chose auto mode it use auto stepper motor type, micro drive, 19nm resolution. You can check point & position of a specimen. User Friendly Operation Nano stationTM is the software for CX-200 based on Microsoft Windows XP and graphic user interface. It is carried out with mouse and keyboard by menu selection. It can provide a high resolution images at a short time.
Type : Automatic
Voltage : 220V
Driven Type : Electricity
Warranty : 1 Year
Eyepieces : WF10X, WF15X
Vision Angle : 5-10Degree
...moreReal-Time Acquisition
OceanViewYou may use our flagship desktop spectroscopy application, OceanView, to manually configure acquisition parameters and graph the results, or use its built-in "Application Wizards" to walk you through standard spectroscopic techniques such as absorbance measurements or locating Raman peaks. OceanView also allows you to design your own custom measurement procedures using a "visual schematic" view that lets you drag-and-drop spectrometers, transform functions and display nodes to automate your unique post-processing workflow. OceanView is the recommended software for use with Ocean Optics spectrometers.
...morePower Processing System
AeroVironment power processing systems offers a full range of power processing systems to meet your testing and development needs. AeroVironment's equipment is in use by customers around the world improving the quality of our customer's products. The markets served by our products include: electric and hybrid vehicles, fuel cells, and energy storage. Any application where a sopisticated electronic load is required will benefit through the use of AeroVironment's technology.
...morePortable High Speed Interferometer
This hand portable, remote sensing field and industrial instrument is lighter and more versatile than our Model 101, which has served the research needs of scientists and engineers worldwide since 1991.
Features : Lightweight, Single Package Design,Thermally Stabilized Interferometer,Embedded Pentium® PC Computer
...morePortable Handable UV Vis Nir Spectroradiometer
Spectra Vista Corporation is dedicated to the manufacturing, delivery and support of Airborne Imaging Spectrometers & Field Portable Spectroradiometers for the Remote Sensing Community
...moreparticle size analyzer
CPS Disc Centrifuge, Models DC12000, DC18000, DC20000 and DC24000 - the world's fastest, highest resolution, and most sensitive centrifugal sedimentation particle size analyzers. Measure virtually any type of particle, between 0.01 and 50 microns, at 2 to 10 times better resolution than any other particle sizing instrument, regardless of measurement technique. The minimum reportable peak width can be less than 2% of peak diameter. Particle size Calibration Standards - 0.15 micron to 165 microns peak size; distribution widths of +-9% of peak diameter to +-2% of peak diameter.
...moreOptical Profilometer
The Holographic MEMS Analyzer measures 3D vibrations over the full field of view without XYZ scanning. Millions of data points are acquired simultaneously for measurement of 3D vibrations with similar resolution as a laser vibrometer. MEMS Analysis Tool Software It is a post processing software that provides a solution for performing detailed and precise analysis of the 3D dynamic response of MicroElectroMechanical Systems (MEMS). The data produced by Koala Acquisition & Analysis can be directly analyzed by this software to perform analysis of MEMS MEMS geometries and movements are often complex to analyze with the presence of holes, or multiple structures. Displacements can be very small laterally and vertically, or very large compared to the structure size.
Feature : Frequency range from Static to 25MHz,Measure vertical velocities up to 10 m/s
...moreOmni device drivers
omnidriver-480For complete programmatic control, we offer a range of device drivers providing direct control of every spectrometer function. Our OmniDriver high-level application driver provides convenient wrapper interfaces (DLLs), Java .jar files and sample code for all popular programming languages (including Java, C#, C++, C, LabVIEW, MATLAB and Delphi) and operating systems (Windows XP78, MacOS, Linux). OmniDriver is designed to support every feature of every spectrometer and programmable accessory we produce, and in fact underlies our own OceanView desktop application.
...moreNanodrop Lithograpghy
Precise dropping of samples at predetermined places, no. of drops (picoliter, ~ 70um size), 5cm X 5cm XY movement, resolution 100nm
...moreLight Source
The DH-2000-BAL is the world's only balanced deuterium halogen source. It uses innovative filtering technology to produces smooth spectrum across entire range. This same technology eliminates the alpha deuterium line in the visible region. Using a combination of deuterium and halogen lamps, the DH-2000 is flexible and ideal for measuring a sample that has multiple features in different spectral regions or for analyzing a variety of different samples in your lab. All deuterium sources have an alpha line, a sharp spectral feature centered at 655 nm. This feature and other deuterium lines produce "unbalanced" output in the deuterium and halogen sources. Simply adjusting the integration time of the spectrometer to suppress the alpha line does not solve the problem as the efficiency of the system at UV wavelengths drops significantly, compromising signal-to-noise performance. A system of proprietary internal mirrors and filters to eliminate the D-alpha, D-beta and Fulcher lines in the deuterium source, producing a "smoother" spectrum across the entire wavelength range and eliminating problems associated with saturation. By comparison, most combination UV-NIR sources can be adjusted for relative intensity only.
...moreLaser Raman Spectrometer
The STR250 Laser Raman Spectrometer is a highly compact, and flexible system with a high sensitivity to measure an weak Raman scattering from different materials.The system consists of an imaging spectrometer and TE cooled CCD camera. We offer a remote probe head for remote sampling, a optical microscope for small sample with spatial resolution < 1mm, and dual excitation lasers for visible and Near IR region. Near IR laser will resolve the florescence problem from the organic compound. The system include user friendly Windows based control and data processing software.
...moreIRIS - Inline Hotspot Inspection
First released in 2009, Tau Science’s IRIS product line screens for electrical shunt defects in cells which will lead to localized hotspots – a leading cause of PV cell performance problems and module degradation. Tau Science was the first company to bring a turnkey hotspot inspection system to the market and has built up years of experience delivering solutions to PV manufactures around the world. We continue to lead this field with the second generation product, introduced in 2011, that sets new standards of precision and accuracy at throughputs exceeding 3000 cells per hour.
...moreIonEtch Sputter Gun
The tectra IonEtch ion gun is a filamentless ion source based on a microwave plasma discharge. Like its big brother the Plasma Ion Source, the IonEtch works by coupling microwave energy into a coaxial waveguide and from there via evanescent wave coupling, into a plasma chamber. The intense oscillating electric fields cause the gas to breakdown and a plasma discharge to take place. A quadrupole magnetic field around the chamber further enhances the plasma density via the Electron Cyclotron Resonance (ECR) effect. Ions are extracted from the plasma using simple two or three grid single-hole extraction optics. The use of microwaves to sustain the plasma allows ions to be extracted at very low energies without the plasma collapsing (down to 25eV) and since there are no hot metal electrodes in the plasma also permits the use of reactive gases such as oxygen and hydrogen. The new GenII is the second generation of the IonEtch sputter gun with some significant improvements in performance and features. To name only some: higher total beam current, high efficiency direct microwave coupling without need of tuning, Alumina plasma cup now standard, only 4 screws to undo non-bakeable parts and more compact, space saving air side setup. Besides the standard version a high current version of the IonEtch sputter gun is available with up to 4mA ion current and 120µAcm² at 100 mm working distance.
...morehigh-performance raman
ISS technology combined with Becker & Hickl electronics for precise TCSPC measurements with a variety of pulsed light sources. The ProRaman-L Series are high-performance laboratory Raman instruments suitable for industrial applications or labora-tory experiments requiring an affordable, high sensitivity Raman instrument. The ProRaman-L features a high sensitivity CCD spectro-graph with CCD cooling temperature to –60ºC, and high through-put laboratory fiber optics probes. Each system includes a note-book computer preloaded with RamanReader software for opera-tion. The excitation laser are available at 532nm and 785nm. The ProRaman-L instruments are ideal for demanding Ra-man analysis in academic, research, industrial laboratories and process line requiring an affordable, high performance Raman instrument.
...moreFuel Cell
IFCT Supplies the World Standard for Testing Hardware Systems use LabVIEW Based Software for Ease of Use and Maximum Flexibility The Optional AC-Impedance System Uses the Sines Correlation Method with a High Speed National Instruments Card to Produce the Most Accurate Impedance Measurements in the Fuel Cell Industry. Power Ranges are Available from a Low of 2 mW to a High of 5 kW.
...moreBe first to Rate
Rate This