Cautery Machine Dealers in Morta, Ghaziabad

(3 products available)
  • Electrosurgical Cautery Machine

    Electrosurgical Cautery Machine

    Get Price Quote

    Monopolar diathermy is the emitance of the HFAC from the diathermy via an active electrode through the patients body tissues and then returned back to the diathermy machine via a dispersive electrode (patient return pad)   Bipolar diathermy is the emitance of the HFAC from the electrosurgery diathermy down one prong of a bipolar forcep through the tissue that has been placed between the forcep tips and returned to the diathermy via the second prong. Bipolar diathermy does not require a dispersive electrode (patient return pad).   Background   Surgical instrument india has three effects on body tissue: cut - generation of heat destroys tissue cell coagulation - tissue cells contract to increase normal clotting fulguration - cell walls destroyed through dehydration   Each of these processes generates smoke plume which contains: chemical by-products (eg toluene, acrolein, formaldehyde, benzene and hydrogen cyanide) intact cells, cell parts and intact viral DNA viable bacteria, including mycobaterium tuberculosis, have also been cultured To minimize associated health hazards, specially designed smoke evacuation systems should be used where available and surgical filtration masks donned for all surgical procedures.   Prior to use   The Electrosurgery Unit (ESU) should only be use by members of the peri-operative team deemed competent. The ESU should be inspected and safety features tested (eg lights, activation patient return electrode sound indicator) before each use All cables and electrodes must be checked prior to use to ensure insulation is intact Any problems must be reported to the Biomedical Engineering Department immediately. The volume of the activation sound indicator should be maintained at an audible level   General use   The diathermy surgery should be protected from spills. Fluids should not be placed on top of the ESU The dispersive electrode should be the appropriate size for the patient’s weight and an electrode should never be cut to size Only those active electrodes recommended by the manufacturer should be used. If an adapter is used it should be one that is approved by the manufacturer and does not compromise the generator's safety features. After the patient is positioned on the operating table, the dispersive electrode should be placed on a clean, dry intact skin surface over a large, well perfused muscle mass The dispersive electrode should not be placed over. a bony prominences implanted metal prosthesis areas distal to a tourniquets scar tissue hairy surfaces pressure points/areas   The electrode should be positioned as close to the operative site as possible The dispersive electrode should be connected to the ESU prior to draping to ensure adequate contact & then the lead disconnected from the ESU temporarily to allow for the draping of the patient and the positioning of the surgeon   Mono Polar/Bipolar Surgical Diathermy AYU 250 ANL is a high frequency Electro Surgical Unit Micro controller based innovative design, together with high reliability makes AYU 250 ANL Electro Surgical Diathermy unit the most favorable choice of doctors. The technical ability of the unit is combined with patient's safety that are of prime importance both for patient and the user. The AYU 250 ANL Electro Surgical Diathermy is designed with SMPS power supply which provides particular safety and reliability. AYU 250 ANL is user friendly Electro Surgical unit. SAFETY IN USE The Technical conceptions of the AYU 250 ANL meet the requirements of highly refined Electro Surgical techniques all national and international safety standards are confirmed. The micro function and knob allows for an instant variation in the output power for more delicate application such as neurological or micro surgery.   Ortho Peallic Dermatology Otolaryngology Ophthalmology Ginaecology Aesthetics Vascular Disease

    more..
  • Electrosurgical Pencil

    Electrosurgical Pencil

    Get Price Quote

    In addition to our complete line of bipolar cables, we also have bipolar adaptors for use with disposable electrosurgical pencils. Please see Bipolar Adaptors product Document for detailed information.

    more..
  • Best Deals from Cautery Machine

  • ANL Surgical Cautery

    ANL Surgical Cautery

    Get Price Quote

    • Type: Other
    • Properties: Abdominal Surgery Equipments
    • Model Number: AYU-250-ANL
    • Place of Origin: India
    • Supply Ability: 100 Unit/Units per Month
    • Packaging Details: EXPORT CARTON PACKING
    more..
Filter by Locality
top