Chemical Earthing Electrodes
Get Price Quote
100 Piece (MOQ)
We are counted among the well known Manufacturers, Suppliers and Exporters of Chemical Earthing Electrodes. The Electrodes we make available dissipates lightning strikes and discharges. EPABX Systems/RF Antennae, Transformers HT/LT, Panels Distribution/Power factor, CNC m/c, Testing Equipment /System, Uninterrupted Power Supply, Generators, etc. are some of the components required for the proper functioning of our Earthing Electrodes. One can obtain these at market-leading rates from us. Statutory Requirements ofEarthing/Grounding of System/equipmentAs per Indian Earthing Standard IS 3043:1987EPABX Systems/RF Antennae Etc Provision should be there for at least one distinct separate dedicated body Earthing in order to provide safety aspects for shock to human life and charge dissipation of spurious voltage generated by the system because of surges. Provision should be there for at least one distinct separate dedicated Neutral Earthing in order to provide localized Neutral to make Neutral strong and provide path to residual voltage of Neutral. The Neutral-Earth voltage should be measured, and it should be low as 2 -3 volts or less as possible. In case of high Neutral-Earth a separate localized Earthing point should be connected to Neutral of the system Transformers HT/LT In case Transformers HT/LT : Provision should be there for at least two distinct separate body Earthing in order to provide safety aspects for shock to human life. The Neutral should be Earthed with at least two distinct separate interconnected Earthing in order to achieve sufficient current dissipation and consistent/low neutral – earth voltage.Panels Distribution/Power factor In case of Panels for Distribution/Power factor : Provision should be there for at least two distinct separate bodies Earthing in order to provide safety aspects for shock to human life. CNC m/c In case of medium and high rating CNC m/c : Provision should be there for at least two distinct separate body Earthing in order to provide safety aspects of electronic circuit and for shock to human life. It provides safety of electronic circuit against surges/spikes generated by the induction current. The Neutral should be Earthed with at least one distinct separate Earthing in order to achieve sufficient current dissipation and consistent/low Neutral – Earth voltage.Testing Equipment /System Provision should be there for at least one distinct separate dedicated body Earthing in order to provide safety aspects for shock to human life and charge dissipation of spurious voltage generated by the system because of surges. The Neutral-Earth voltage should be measured, and it should be low as 2 -3 volts or less as possible. In case of high Neutral-Earth a separate localized Earthing point should be connected to Neutral of the system. Uninterrupted Power Supply Provision should be there for at least one distinct separate dedicated body Earthing in order to provide safety aspects for shock to human life and interruption of sinusoidal charge dissipation of spurious voltage generated by the system because of surges. The Neutral-Earth voltage should be measured, and it should be low as 2 -3 volts or less as possible. In case of high Neutral-Earth a separate localized Earthing point should be connected to Neutral of the system. Generators In case of medium and high rating generators : Provision should be there for at least two distinct separate body Earthing in order to provide safety aspects for shock to human life. The Neutral should be Earthed with at least two distinct separate interconnected Earthing in order to achieve sufficient current dissipation and consistent/low neutral – earth voltage In case of Extra high rating generators: Number of Body/Neutral earthing points should be increased in order to cope up with high spurious voltage generated by the equipment.
Chemical Earthing Electrodes
1,000 Per Piece
Best Deals from Chemical Earthing Electrodes
chemical earthing material
Get Price Quote
Living up to our reputation, we present you Chemical Earthing Material. Enhanced with industrial expertise, we are a reputable figure in the industry. Our vendor management process makes certain that we procure from the vendors who can deliver the proposed quality consistently. It is equipped with features such as rigid construction and durable finish standards. We make the product available for bulk orders at market leading rates.
Chemical Earthing Electrodes
Get Price Quote
50 Piece(s) (MOQ)
Chemical Earthing is essential a maintenance free earthing. SG Earthing Electrodes are widely used as best chemical earthing solutions. Electrodes are available in both Pipe in pipe and Strip in Pipe concepts. Electrodes are available in all std combinations and can be made as per customer requirement. Best quality Earth Enhancing compound is used to ensure no watering required. Electrodes are capable to handle every fault current surges. Chemical earthing has essentially an edge over conventional earthing as instead of charcoal and salt ground enhancing chemical is poured surrounds the sealed electrode and that chemicals dissipated ions even in dry condition so regular watering is not required in chemical earthing. Models Electrode Diameter (MM) Length (MM) Internal Strip Size (MM) Conductive mineral filled SG 2402503 GI 40 2000 25 X 03 Yes SG2402504 GI 40 2000 25 X 04 Yes SG3402504 GI 40 3000 25 X 04 Yes SG2503004 GI 50 2000 30 X 04 Yes SG3503004 GI 50 3000 30 X 04 Yes SG2755006 GI 75 2000 50 X 06 Yes SG3755006 GI 75 3000 50 X 06 Yes Advantages Low-Impedance Grounding High life Reliable Require minimal maintenance Longevity SG Earthing Electrode Provide Chemical Earthing manufacturer, Chemical Earth Pit, manufacturer chemical earthing with Maintenance free earthing manufacturer play a vital role in saving Human life as well as machines lives
Chemical Earthing Electrode
Get Price Quote
Our clients can also avail BFC Powder that are acknowledged for their reliability. These are manufactured with the use of components of high quality that are procured from reliable vendors of the market. Our products are highly conductive and non corrosive and eliminate the use of salt and charcoal around the electrode. Some other features of our products are: •Reduce soil resistivity •Aid faster dissipation of fault current •Ensure minimal fluctuation of OHMIC value
Chemical Earthing Electrodes
Get Price Quote
Chemical Earthing Electrode
Get Price Quote
Chemical Earthing Electrode, Chemical Earthing Electrodes
Chemical Earthing Electrodes
Get Price Quote
Chemical Earthing Electrodes, Lightning Arresters, lightning strike recorder
Chemical Earthing
Get Price Quote
Chemical Earthing, yoke plate, Earthing Coil, bimetallic clamp
Chemical Earthing
Get Price Quote
Chemical Earthing, earthing electrode