MCB & MCCB
Get Price Quote
We are engaged in offering excellent quality MCB & MCCB. The MCB & MCCB we make available are designed as per the set international quality standards. To meet the diverse requirements of the buyers, we offer the MCB & MCCB in different specifications. Bulk orders of the MCB & MCCB are processed by us as per the specific requirements of the buyers. One can obtain the MCB & MCCB at nominal rates.
11kv Vacuum Circuit Breaker
Get Price Quote
We are offering 11kv vacuum circuit breaker, ht panel (indoor type) with ct, pt, metering & standard protection relays for protection of transformer, ht capacitor, generator, ht motor, feeder & line.
Best Deals from Circuit Breaker
Edge Protector
7 - 15 Per Meter
1000 Meter (MOQ)
Angle Boards are basically used at corners of big carton boxes to provide them strength to withstand heavy weights
Lightning Arresters
100 Per Piece
10 Piece (MOQ)
Gi Earthing Pipe
800 - 1,900 Per EACH
5 Piece (MOQ)
32A 300mA DP RCCB
1,108 Per piece
6 Piece (MOQ)
ISI marking Yes CM/L No: 8700003309 CM/L Validity up to 44957 Rated Voltage (Volt) 240V Instantaneous Tripping Range C Governing Indian Standard specification IS/IEC 60898-1:2002 Yes Rated Short circuit capacity (Ampere) 10000 A
Air Circuit Breaker
Get Price Quote
1 Piece(s) (MOQ)
Widest Offering : Range from 400A to 6300A Breaking capacity from 50kA to 100kA Available in 3Pole/4Pole, Manually & Electrically operated, Fixed & Draw-out versions Common height & depth across the range High short time withstand capacity, Icu=Ics=Icw for 1 sec for total selectivity High mechanical and electrical operating life Advanced micro-processor based protection release 50% and 200% neutral protection solution RoHS Compliant User Friendly Features : Breaker can be remotely configure, Operate and Monitor in integration with Smartcomm Integration Solutions Unique breaker front-facia architecture displays the electrical accessories mounted on the ACB (with rated control voltage and type of operating voltage) Modular and snap-fit accessories like under-voltage, shunt and closing coil redefine modularity on a time scale of 5 mins Ease of on-site convertibility from Fix to Draw-out and Manual to Electrical versions Tool-less Arc-chutes removal facilitates quick inspection of electrical contacts User friendly interface for Release configuration Switchboard Friendly : Three compact frame sizes help in optimizing the switchboard True 50% and 200% Neutral Solution for specific user application Common height and depth across the range Terminal adaptors offer ease of configuration of vertical/horizontal busbar arrangements Option of interleaved bus-bar termination offers superior performance Supports multi-tier arrangement with minimal clearance with the help of arc-shield Self-aligning, Snap-fit secondary isolating contacts enable quick termination Option of customized Neutral configuration of 100%N Best in class termination overlap with bus-bars Superior Safety for complete peace of mind : Inbuilt Electrical and Mechanical Anti-Pumping prevent multiple breaker closures due to persistent closing command CE marking Password protection for Protection Releases Arc-chute interlocking prevents the closure of breaker if arc-chute is missing or not properly installed Smart-racking shutter interlock ensures breaker is switched off before racking out the breaker Conforms to Glow Wire Testing Temperature protection by monitoring true terminal temperature
125a 4-poles eaton main switch
1,919 - 2,949 Per Piece
3 pieces (MOQ)
Main Electrical Switch
Get Price Quote
300 Piece(s) (MOQ)
Details -This switch is manufactured by our skilled professionals using the latest technology and in compliance with the set industry standards. Owing to its superior strength and optimum durability, the offered switch is highly demanded among our clients. The offered switch is used to direct electricity from one or more supply source for usage in various smaller areas. Specifications : 16 amp. 240 volt. 32 amp. 240 volt. 32 amp. 415 volt. 63 amp. 415 volt. 100 amp. 415 volt. 200 amp. 415 volt. etc. Features: Flawless finish Shockproof Perfect design
Electra onload changeover switch
1,800 Per Piece
100 Piece(s) (MOQ)
Onload changeover switch open type and with enclosure both available.
Vinyl Insulated Female Disconnector
4 Per pieces
100 Piece (MOQ)
Switch Gear
Get Price Quote
Typically Switch Gear in substations is located on both the high voltage and the low voltage sides of large power transformers. The Switch Gears on the low voltage side of the transformers may be located in a building, with medium-voltage circuit breakers for distribution circuits, along with metering, control, and protection equipment. For industrial applications, a transformer and Switch Gears line-up may be combined in one housing, called a unitized substation or USS. Demanded For Unsurpassed performance Hassle-free working Compact design Reasonable prices
Edge Protector
5 - 45 Per Meter
10 Kilogram (MOQ)
We are pleased to introduce our self as manufacturer and trader of all types of packing materials. We have in house manufacturing unit of PP Strap, Stretch film,Pet Strap, Edge Protector. We are located in Sahibabad industrial area in 2200 sq meter working area. Our products are manufactured on high class imported machines operated by skilled operators. We invite you to visit our factory premises and favor us with your valued orders. We ensure you timely and best quality products.
Residual Current Circuit Breaker
Get Price Quote
Salient features Conforms to IS : 12640 (Part-1)/IEC 61008 - 1, 240/415V, 50Hz with 6 KA Short Circuit withstand capacity Rating Available 40, 40, 63, 63 Number Of Poles DOUBLE POLE FOUR POLE
Lightning Protection Systems
Get Price Quote
Lightning is actually a visible discharge of static electricity within a cloud and also between clouds. The light protection system offered by us provides a means by which this discharge might leave or enter the Earth without actually passing through the damaging non-conducting parts of a structure, like those made of wood, brick, tile of- concrete. Such a lightning protection system does not prevent lightning from striking but provides a means for controlling it and preventing damage by providing a low resistance path for the discharge of lightning energy. The Lightning Protection System has undergone many changes and today's lightning protection system exhibit the best in terms of design, materials and installation, thus valuable life and property can be well protected from nature's hazardous and exciting phenomenons like, lightning. Lightning is a unique form of energy and an expert can only install proper protection systems against it.
Surge Protection Device
1,100 Per Piece
10 Piece (MOQ)
Residual Current Circuit Breaker
Get Price Quote
From large buildings to private homes, from industries to hospitals, electricity is essential. The extensive use of electricity in our daily life has become so common that we tend to forget that careless of electricity can be hazardous. Every year, a large number of industrial & domestic fires are attributed to "electrical faults". Hasintroduced state-of-the-art RCCB, which is capable of detecting earth leakage current as soon as they appear and isolate the system. Operational Principle: RCCB is a current device and is independent of line voltage conditions. This means that it provides protection even when there is voltage dip or the neutral conductor is interrupted. In a healthy system the vector sum of all currents in phase and neutral is equal to zero. The device senses imbalance or residual currents in the system and disconnect supply systems. Specification: IEC 61008-1/IS 12640-1:2008/EN 61008-1 Range: 16, 20, 25, 32, 40 & 63. Features: Simple and robust operating system. Rotary handle with ON/OFF indication. Due termination for bus bar as well as cable connectiion. Advance neutral. Test button for regular inspection. Positive contact indication. Salient Features: Shapes compatible with and suitable for standard busbar connection to other devices. Twin-puurpose terminal (lift/open-mouthed) above and below. Busbar positioning optional line or load. Free terminal space despite installed busbar. Suitable for being used with standard fluorescent tube with or without electrical ballast (typically up to 20 units per phase conductor). The device functions irrespective of the position of installation. Type with 80A permissible short-circuit back-up fuse: Take into account overload protection. Tripping is line voltage-independent. Consequently, the RCCB is suitable for "fault current/residual current protection" and additional protection within the meaning of the applicable installation rules. Mains connection at either side. The 4-pole device can be used for 3-pole connection. For this purpose use terminals 1-2, 3-4, and 5-6. The 4-pole device can be used for 2-pole connection. For this purpose use terminals N-N and 5-6. Pressing the test key "T" serves the only purpose of function testing the Residual Current Circuit Breaker (RCCB). This test does not make earthing Resistance Measurement (RE), or proper checking of the earth conductor condition redundant, which must be performed separately.
Modular Switches
Get Price Quote
Miniature Circuit Breakers
Get Price Quote
MCB's are among the best available designed with proven, trusted and reliable German Technology to provide enhanced operating safety, Installations for domestic, commercial and industrial applications. Some of the salient features of these MCB's are as below. Miniature Circuit Breakers are housed in injection moulded flame retardant, high strength thermo plastic material having high melting point, high dielectric strength and temperature with stand.The Tripping Mechanism is thermal magnetic type : Finger Protection 1. MCB's are finger protected to IP 20 as per IS : 8828 : 1996 the live current carrying parts cannot be touched accidentially. Magnetic Protection 1. When overload values exceed the value specified for different characteristic curves i.e. B & C strong Magnetic field is induced which results into instantaneous tripping of MCB. Effective Quenching 1. Arc produced of contacts is rapidly pushed Magnetically into a 12 plates arc chamber where it is broken down effectively & cooled. Trip Free Mechanism 1. Trip free Mechanism ensure tripping of MCB even if the knob is kept in 'ON' position. Special Silver Alloy Contacts 1. The contacts are made out of special silver alloy inlaid strips which gives low contact resistance resulting in low voltage drop & hence very low power consumption and temperature rise. These contacts have very excellent anti weld properties. Thermal Protection 1. Small overloads are detected by fine calibrated Bimetal which deflects if the current is greater than the rated current and hence tripping the MCB. Dual Termination 1. The incoming terminals are designed for termination of Busbar as well as cable individually or simultaneously. Terminals are suitable for Cables upto 25mm².
home protector
Get Price Quote
home protector, Bird Spike, Anti Bird Net, Monkey Spike, Sports Net