Copper Earthing Electrode
Get Price Quote
With the incorporation of latest technology and skilled workforce, we offer a range of Copper Electrodes. These products offered by us have remarkable resistance against corrosion and ensure uniform earth contact resistance during their entire lifetime. Some other features of our products are: •Optional electrical conductivity •High mechanical strength •Allow connection to Earthing systems like foundation Earthing and others
Chemical Earthing Electrodes
Get Price Quote
100 Piece (MOQ)
We are counted among the well known Manufacturers, Suppliers and Exporters of Chemical Earthing Electrodes. The Electrodes we make available dissipates lightning strikes and discharges. EPABX Systems/RF Antennae, Transformers HT/LT, Panels Distribution/Power factor, CNC m/c, Testing Equipment /System, Uninterrupted Power Supply, Generators, etc. are some of the components required for the proper functioning of our Earthing Electrodes. One can obtain these at market-leading rates from us. Statutory Requirements ofEarthing/Grounding of System/equipmentAs per Indian Earthing Standard IS 3043:1987EPABX Systems/RF Antennae Etc Provision should be there for at least one distinct separate dedicated body Earthing in order to provide safety aspects for shock to human life and charge dissipation of spurious voltage generated by the system because of surges. Provision should be there for at least one distinct separate dedicated Neutral Earthing in order to provide localized Neutral to make Neutral strong and provide path to residual voltage of Neutral. The Neutral-Earth voltage should be measured, and it should be low as 2 -3 volts or less as possible. In case of high Neutral-Earth a separate localized Earthing point should be connected to Neutral of the system Transformers HT/LT In case Transformers HT/LT : Provision should be there for at least two distinct separate body Earthing in order to provide safety aspects for shock to human life. The Neutral should be Earthed with at least two distinct separate interconnected Earthing in order to achieve sufficient current dissipation and consistent/low neutral – earth voltage.Panels Distribution/Power factor In case of Panels for Distribution/Power factor : Provision should be there for at least two distinct separate bodies Earthing in order to provide safety aspects for shock to human life. CNC m/c In case of medium and high rating CNC m/c : Provision should be there for at least two distinct separate body Earthing in order to provide safety aspects of electronic circuit and for shock to human life. It provides safety of electronic circuit against surges/spikes generated by the induction current. The Neutral should be Earthed with at least one distinct separate Earthing in order to achieve sufficient current dissipation and consistent/low Neutral – Earth voltage.Testing Equipment /System Provision should be there for at least one distinct separate dedicated body Earthing in order to provide safety aspects for shock to human life and charge dissipation of spurious voltage generated by the system because of surges. The Neutral-Earth voltage should be measured, and it should be low as 2 -3 volts or less as possible. In case of high Neutral-Earth a separate localized Earthing point should be connected to Neutral of the system. Uninterrupted Power Supply Provision should be there for at least one distinct separate dedicated body Earthing in order to provide safety aspects for shock to human life and interruption of sinusoidal charge dissipation of spurious voltage generated by the system because of surges. The Neutral-Earth voltage should be measured, and it should be low as 2 -3 volts or less as possible. In case of high Neutral-Earth a separate localized Earthing point should be connected to Neutral of the system. Generators In case of medium and high rating generators : Provision should be there for at least two distinct separate body Earthing in order to provide safety aspects for shock to human life. The Neutral should be Earthed with at least two distinct separate interconnected Earthing in order to achieve sufficient current dissipation and consistent/low neutral – earth voltage In case of Extra high rating generators: Number of Body/Neutral earthing points should be increased in order to cope up with high spurious voltage generated by the equipment.
Best Deals from Electrodes
Copper cathode
Get Price Quote
100 Kilogram (MOQ)
Copper Anodes
Get Price Quote
We are counted among the foremost Copper Metal Anodes Suppliers, Exporters and Manufacturers in India. Our Copper Anodes are made from superior quality copper that assures their optimum quality. The Copper Ball Anodes that we manufacture are used for various laboratory purposes mainly for the electro refining of copper. They are supplied to various chemical industries, labs, etc. Our Plain Copper Anodes are available in various dimensions and can be customized as per the requirements of the clients. Our clients in India and abroad are highly satisfied by the supreme quality of our copper anodes and their delivery within the provided timeframe.
Welding Electrode
360 Per Kilogram
100 Kilogram (MOQ)
Earthing Electrodes
1,200 - 1,400 Per EACH
Welding Electrode
77 Per Kilogram
Ador Hard Facing Electrode
Get Price Quote
Tungsten Electrode
45 - 120 Per Piece
North welding torches, 300 AMPS WELDING MACHINE, Switch Welding Machine
Graphite Electrodes
Get Price Quote
We provide high quality graphite electrodes in various dimensions as per client requirements
Button Electrode (Solid Gel) 1 pack/50 Electrodes
Get Price Quote
We offer button electrode.
Copper Anodes
Get Price Quote
LED Lights Heat Sink, Aluminium Channel Extrusions, anodizing services
Welding Electrodes
Get Price Quote
Welding Electrodes, Industrial Products
Welding Electrodes
Get Price Quote
Welding Electrodes, Welding Equipments
emitting electrodes
Get Price Quote
emitting electrodes, Roller Journel Shaft, Pulley Shaft
MS Electrode
Get Price Quote
MS Electrode, medical oxygen gas, Nitrogen Hydrogen Gas, Co2 Gas
Welding Electrodes
Get Price Quote
Welding Electrodes, Engineering Products, Industrial Lubricants
Chemical Earthing Electrodes
Get Price Quote
Lightning Arresters, Voltage Surge Suppressors, Surge Protection Device