Interferential Therapy Unit Dealers in Morta, Ghaziabad

(4 products available)
  • interferential therapy

    interferential therapy

    Get Price Quote

    • Dimension (L*H*D): 352mm, 125mm, 331mm
    • Weight): 5 Kg Approx.
    • Operating Voltage: 110-270V 50Hz
    • Absorption: 46-Watts Max
    • Fuses: 1 Amp
    • Room Temperature: 10ºC to 40ºC
    • Moisture: 10% to 80%
    • Preset Programs: 50 program
    • Customize Program: 99 Create Programs
    • Probe Test: Cable & Electrode Test
    • Max. Output Current: 100mA Digital Display for CH-1 & CH-2
    • Max Output Voltage: 100V (Peak to Peak)
    • Medium Frequency: 2 KHz& 4 KHz
    • Base AMF: 0-250 Hz
    • Spectrum: 0-250 Hz
    • Therapy Mode: 4P, 4PV, 2P
    • Wave shape: Tra, Tri, Rec.
    • Vector Mode: 2PL, 4PL, 4PT, 4PNL
    • Treatment Time: 01 to 99 Minutes adjustable
    • Patient Safety: Available
    • RUSSIAN CURRENT: Medium Frequency
    • 2.5 KHz: Base AMF
    • 0-200 Hz: Spectrum
    • 0-200 Hz: DIADYNAMIC CURRENT
    • Current Mode: CP, LP, DF, MF
    • Low Frequency: 50Hz & 100Hz
    more..
  • Interferential Therapy (ALUMINUM)

    Interferential Therapy (ALUMINUM)

    22,000 Per Piece

    • Weight: 1.5Kg (Approx)
    • Dimension (L*H*D*): 325mm x 85mm x 290mm
    • Operating Voltage: 230V AC, 50Hz
    • Output type: 100% Isolated
    • Medium Frequency: 4kHz and 2kHz
    • No of Program: 00 to 28 Total 29 nos.
    • Output Current: Two Separate outputs CH-1 & CH-2
    • Output Frequency: It can be varied by intensity Control
    • Patient Frequency: Available

    INTERFERENTIAL THERAPY In the interferential Therapy, we make use of two medium frequency alternatively currents. These medium frequency currents are not identical and may differ in frequency up to 150 Hz. Two oscillator of medium frequency are generated and are cross wisely applied to the body by means of four electrode pads.   Application : Important frequencies in – electro therapy are between 0 and 250 Hz. In interference therapy these frequencies are generated in the tissue by the superposition of two currents. Due to high frequency of the current intensities are used. Thus areas deep in the body can be stimulated.

    more..
  • Best Deals from Interferential Therapy Unit

  • Interferential Therapy Tens Digital Unit LCS

    Interferential Therapy Tens Digital Unit LCS

    Get Price Quote

    • Weight: 5 kg Approx
    • DIMENSION (L*H*D): 358mm, 149mm, 354mm
    • OPERATING VOLTAGE: 220V 50Hz
    • ABSORPTION: 50 Watts
    • FUSES: 1 Amp
    • ROOM TEMPERATURE: 10° to 40° C.
    • MOISTURE: 10% to 40%
    • Display: LCD large 20x4
    • Preset Program: 10
    • Customise User Program: 50
    • Max out-put Current: 100mA Digital Display CH1 & CH2
    • Carrier Frequency: 2 KHz & 4 KHz
    • Base AMF: 1-150 MHz
    • Spectrum: 01-150 MHz
    • Therapy Mode: 4 Pole Classic, 4 Pole Vector, 2 Pole Modulated
    • Time: 60 Min