Temperature Controller Dealers in Vasundhara, Ghaziabad

(14 products available)
  • Temperature Indicator

    Temperature Indicator

    400 Per Piece

    • Application: Industrial, Commercial
    • Display Type: Digital
    • Feature: Rust resistance
    • Application: Industrial
    • Condition: New
    • Frequency: 50 - 60 Hz
    • Voltage (V): 220
    • Performance: Optimum
    • Speciality: Long functional life
    • Advantage: Easy to Operate
    more..
  • Temperature Controllers

    Temperature Controllers

    1,700 Per Piece

    • Display Type: Digital
    • Accuracy: +/- 0.5 Deg C
    • Model No.: PT-100
    • Controller Function Type: On-Off
    • Display: 4 digits
    • Measurements: 35 x 77 x 71 mm
    more..
  • Best Deals from Temperature Controller

  • J & K Type Thermocouple

    J & K Type Thermocouple

    310 Per Piece

    For years, we are engaged in dealing of Thermocouple J And K Type, as we are its reckoned supplier in the market. Raw materials that we source from the trusted vendors are used as input in the production procedure and thus we check them against varied quality parameters before procurement. Specifications : Usage - For measuring temperature Type - J and K Features : Excellent strength Easy to use Fine finish

    more..
  • winding temperature indicator

    winding temperature indicator

    2,500 Per Piece

    10 Piece (MOQ)

    • Material: Stainless Steel
    • Color: Grey
    • Application: Winding Temperature
    • Display Type: Digital
    • Country of Origin: India
    more..
  • SENSORS THERMOCOUPLE

    SENSORS THERMOCOUPLE

    Get Price Quote

    Image result for thanks in emails Picture Subodh Mishra (Head-Marketing & Sales) MS. PACK MACHINE ENGINEERS, HO:C-786, Saheed Nagar, Ghaziabad -201006 (INDIA) (Mfg:All Kinds of Pouch Packaging Machine Perforation Cutters, Pillow Pack Machine Blades, Zig Zag Blades, Cartage Heaters , Thermocouple and Proximity Sensors)

    more..
  • ANALOGE TEMPERATURE CONTROLLER

    ANALOGE TEMPERATURE CONTROLLER

    Get Price Quote

    • RANGE & TYPE: 0 - 400 oC (J Type), 0 - 1200 oC (K Type) Factory Setting.
    • SENSOR INPUT: J Type, K Type (Factory Setting)
    • MODEL: Bita (96), Alfa (72)
    • POWER SUPPLY: 220V AC ±10%, 50 Hz.
    • OUT PUT: Relay Output - 1C/O, 7Amp.
    • SETTING: By POT Knob on front.
    • SIZE & MOUNTING: 96x96x110/ 72x72x110mm. & Panel Mounted.

    APPLICATION Heat Treatment Plastic Processing Machinery Laboratory Equipment.....etc. Food Processing. Environmental Chambers.

    more..
  • Resistance Temperature Detector

    Resistance Temperature Detector

    Get Price Quote

    Resistance Temperature Detector(RTD) used for temperature measurement -50 to 400 Deg.C. The system accuracy begins with proper primary sensor selection. Various considerations apply to the design of RTD assemblies. The element should be protected from shock and vibration, yet free of expansion stresses that may shift the reading. The element assembly needs to be isolated without obstructing heat flow. The outer sheath has to withstand pressure, erosion and vibration, yet it should be small enough for easy installation and rapid response to temperature changes.

    more..
  • K Type Thermocouple

    K Type Thermocouple

    Get Price Quote

    Temperature measuring point : Pick shell / insulation / dew point. Thread : 4/1, 5/16, M8, M6, M12. Temperature range : -50°C~950°C. K Type Thermocouple is the most common type of thermocouple. It is reliable, inexpensive, and accurate and its temperature range is wide. It is mostly used in nuclear applications due to the relative radiation hardness. The maximum temperature (continuous) is nearly 1,100°C. These types of thermocouples are used widely in the industry. They have very good resistance to oxidation and high thermopower. They provide us with correct temperature monitoring in the range between  -200°C and  1370°C (-328°F to 2498°F). They consist of nickel-5% aluminum and silicon (-) wire vs. nickel-10% chromium (+) wire. One should use this kind of thermocouple in oxidizing or inert atmospheres. The heating element like electric heaters is the best source to heat it up. They are mostly used at temperatures over 540°C (1004°F) because of the higher oxidation resistance as compared to J, T or E types of thermocouples. The range of K Type Thermocouple : Extension wire –   Between 32° F and 392° F (0°C to 200°C) Thermocouple grade wire – Between 454° F and 2,300° F (–270°C to     1260°C) Accuracy (which will be greater) :Special Limits of Error       –                 +/- 1.1C or 0.4% Standard                             –                  +/- 2.2C or +/- .75% Names of Elements : For describing the positive element of this type of thermocouple (KP), following names can be used: ThermoKanthal-KPs, HAI-KP1, Tophel+, Nickel-chrome, Chromel2, and T-13. The negative element of this type of thermocouple (KN), is described by these names: ThermoKanthal-KNs, HAI-KN1, T-2s, Nial+, Nickel-silicon, and Alumel2.   Cautions to Take: Some conditions should be avoided while using this type of K thermocouple. It should not be used in vacuum applications because of the vaporization of chromium in the positive element. Also, it is not supposed to be used in the sulphurous environment as both of the elements will corrode rapidly and eventually the negative element will fail mechanically because of being brittle. One should also avoid reducing atmospheres. The green-rot phenomenon can be caused due to low oxygen levels. In this phenomenon, chromium in elements will start oxidizing which cause very large negative drifts in calibration. Take a look here as well, actually, If you are a wholesaler then you can have direct contact to thermocouple manufacturers near your area for bulk order. Type K Thermocouples are specified at the time when metallurgy was not as advanced as it is nowadays. As a result, the characteristics can vary extensively between samples. Nickel which is the constituent metal of K type thermocouple is magnetic. Thermocouples made with magnetic material have a characteristic that they are subjected to a deviation in output whenever the Curie point is reached by the material. This happens with thermocouple type k at nearly 185 °C. Hope you like the content and him information given by us. If still have any query about the product or anything then don’t forget to contact us.  FEATURE:- Premium Quality. Affordable Reliable Product Details: Minimum Order Quantity: 6 PiecePower(Watts): As per requirement of applicationVoltage: As per requirement of applicationSize: As per requirement of application

    more..
  • RTD Sensors

    RTD Sensors

    Get Price Quote

    Pressure Gauges, Temperature Gauges, Differential Pressure Gauge

    more..
  • Servo Controller Repairing Service

    Get Price Quote

    Servo Controller Repairing Service, siemens servo drives

    more..
  • Temperature Controllers

    Get Price Quote

    Temperature Controllers, Packaging Machines, Coil Winding Machines

    more..
  • Temperature Indicators

    Get Price Quote

    Temperature Indicators, Pressure Switches, pid controllers

    more..
  • Temperature Controller

    Get Price Quote

    Temperature Controller, electrochemical instruments

    more..
  • J Type Thermocouple

    Get Price Quote

    stripe heater, Mica Heating Elements, Ceramic Heating Element

    more..
Filter by Locality
top