Water Level Controller
12,500 - 15,000 Per Unit
We are manufacturer ofSemi/Fully Automatic Pump Controller or water level controller for your home and industry. It continuously monitors the liquid level of the overhead tank and reservoir.The Automatic pump controller controls the water pumps and turns it ON and OFF with respect to the level in the water tank. This auto-switching feature saves manpower. Hence no need to operate manually. There for no wastage of water, stop tank overflow, save water & electricity bill. Features: Auto start &stop according the tank level Digital display to show level (in percentage) Audio alarm on full tank Push button to reset buzzer Maintenance free, high quality magneticfloat sensor It is suitable for 1/ 3 phase motor.
Type : Automatic
...moreThree Phase Star Delta Motor Starter
12,000 Per Piece
1 Piece(s) (MOQ)
ï Digital Overload Relay. ï Protection â Overload / under load, Single Phase, Phase reversal. ï Digital Display â Volt, Amp. &Run hrs. ï Auto/manual mode selector switch.
Size : Depend upon rating
Type : Electrical
Brand Name : SUBECH
Warranty : 1 Year
...moreThree Phase Motor Starter Control Panel
15,700 - 18,900 Per Unit
5 Unit (MOQ)
Three Phase Motor Starter Control Panel are very much suitable in domestic, agriculture for irrigation and industrial purposes. They can be operated in a voltage range from 170-470 VAC. 01 to 100 HP Starters developed with micro controller Digital overload relay for monitoring /controlling for more protection of motor and PMC (Pre Magnetic Contractor) for instant switching. PMC is a modified concept of contractor with benefits of cost effectiveness & free from problems of Chattering & Coil burning. In digital overload relay, you can program the voltage range as well as current range within which the motor has to be operated. Starter will trip the motor if supply parameters go out of range. It can be operated in AUTO or MANUAL modes. When the AUTO mode is once selected, it automatically starts the motor whenever the power resumes in all three phases in healthy condition. While in the manual mode, one can manually start and stop the motor instantly with the help of separate smooth push buttons. The starter is having smart digital ampere, volt and hour meter. Features : Over load Protection (Programmable) Under Load Protection (Programmable) Under voltage protection (Programmable) Over voltage protection (Programmable) Single phase preventer Reverse phase protection Unbalance voltage protection Auto/manual mode selector switch Inbuilt MCB /MCCB to extra protection Hour meter to show the total time of run Digital Amp. & volt meter inbuilt Auto switch inbuilt with Start delay time Wide voltage range - 170 - 450 VAC Fabricated with powder coated G.I. sheet Continuous running capacity - 100 + Hrs
Country of Origin : India
Size : Customised, Standard
Type : Three-phase Control Panel
Application : Control Panel
Color : Grey
Voltage : 380V
Material : Mild Steel
Power : 9-12kw
Power Source : Electric
Phase : Three Phase
Warrenty : 1 Year
Autoamatic Grade : Fully Automatic
Brand : SUBTECH
Material : GPSP
...moreThree Phase DOL Motor Starter
4,000 Per Piece
1 Piece(s) (MOQ)
Over load automatically cut off Under voltage / over voltage automatically cut off Single phase preventer Auto/manual mode selector switch MCB to interrupt the supply in faulty condition Hour meter to show the total time of run Reverse Phase protection. Startup delay time.
Type : Electrical
Brand Name : SUBECH
Warranty : 1 year
...moreSump Pump Control Panels
Sump Pump Control Panel may be designed to control one pump or multiple pumps (Duty / Standby, Lead / LaG, etc.) as needed. Sump pump include power components to control the pump motor, motor and pump sensors to protect the motor and pump and field sensors to monitor the process and control pump operation. Features Automation Sump Pump Control Panel Automation of Sewage Pump, of Sewage Tank. Necessary safety features like Overload Protection Under Load Protection (Dry Run), Under/Over Voltage Protection, Single Phase Preventer & Reverse Phase Protection Operate Two or Three Pump simultaneously or alternatively
Application : To control the pump motor, motor and pump sensors
Condition : New
...moreStreet Light Control Panel
43,070 Per Piece
1 Piece (MOQ)
Street Light Control Panel
It is used to operate street lights automatically according to the set program to save huge amount of electricity and money and also to facilitate the people travelling on the roads.Features : Pre programmed Time switch as per season with Three Programs every month and for twelve months thirty six programs specially designed for Street Light Automation. No need of reprogramming & rewiring. User-friendly, Energy saving Efficient, Capable in Lowered CO2 Emissions. Capable of Saving Energy 35-40 %.( Depend upon user usage). Low running and maintenance cost. Availability : Contactor based and PMC based
Material : Metal
...moreSolar Water Pumping System
Solar pumping system consists of four parts: solar panels, solar pump controller, single phase or three phase pump and water drives AC pump to pump water from borehole, river, lake etc. to the storage device. The inverter applies high efficiency MPPT algorithm to maximize power harvested from solar panels. It will make the system to maximize efficiency to get the water as much as possible. The solar pumping system fulfills concept of low carbon, energy conservation, environmental protection to improve the living standard in water-deficient area.
Type : Automatic
Voltage : High
...moreSMPS Battery Charger
1,600 Per Piece
Salient Features: Suitable for charging generator’s battery LED indications Fault protection Reverse polarity protection Boost and trickle modes Input volt: 160-260 VAC, 50 Hz
Country of Origin : India
Type : Smps Battery Chargers
Brand Name : SUBTECH
Input Voltage : 160 - 260 VAC
Warranty : 1 year
...moreSingle Phase Motor Starter Control Panel
Application : Industrial
Phase : Single
Programmable Timer Switch
2,475 Per Piece
50 Piece (MOQ)
Brand Name : Subtech
Switch Type : Real Time
Display Backlight : No
Number Of Programing Channels : 16
Material : ABS
Packaging Type : Paper box
Awg Gauge : non
Fixing Mode : base
Connections-Terminals : brass Pins 5 nos.
Width : 50mm
Height : 60mm
...moreProgrammable Digital Timer Switch
1,500 - 1,950 Per Piece
Digital Time Switches are used where electrical equipment must be periodically switched on and off for pre-programmed daily or weekly times. Digital time switches available with only 5 pin timer. The 5 pin model connection is an AC 220 is just like a switch. It can be used for switching to any application individually or with group of appliances.Features : Digital programmable Daily, weekly timer basis. Upto 16 programs daily Supply voltage - DC 12V, 24V, AC110-260V Freq–50Hz Inbuilt rechargeable V80H battery for memory backup means no issue of replacing battery, Battery charge last for at least 1-2 months without charge. i.e. Without AC supply connectivity. Led power indicator, LCD on screen displays for on and off switching status. Contact – single pole - single throw, Contact capacity-16 Amp, 240 VAC. Running accuracy ± 1 second / day at 20°, Minimum time setting - 1 minute. It can be used for street lights, motors, T.V., AC etc.
Country of Origin : India
Brand Name : Subtech
Material : PVC
Shape : Square
Color : White
Design : Standard
Max. Voltage : 220V
Mechanical Life : 2 Year
Current Rating : 16A
Phase : Single Phase
Switch Display : Digital
Switch Type : Shutter Timer Switch
No Of Switch : 2 Switch
Switch Operation : One Way
Certification : ISO 9001:2008 Certified
Surface Finishing : Polished
Switch Size : 1 Module
Usage : Restaurants, Residential, Office, Home, General
Packaging Type : Box
Specialities : Rust Proof
Overall Dimension : 4X2X2cm
Length : 45-55mm
Temperature Range : 35
Accuracy : 1%
Capacity : 16A
Number Of Programing Channels : 16
...morePower Management System
255,000 Per Unit
1 Unit (MOQ)
Type : Manual, Fully Automatic, Semi Automatic
Brand Name : SUBTECH
Color : Siemens gray
...moreMotorized Butterfly Valve
27,500 - 28,800 Per Piece
SUBTECH series UPVC plastic butterfly valve according to the different medium has a variety of optional material; corrosive resistance is strong, small volume, light weight, extremely non-toxic material. The Mid Stem Structure in this butterfly valve will protect the water leakage from butterfly valve to motor. It is used in industries, multi storied buildings, malls to control the flow of liquids. Features : Can be operated automatically, manually or remotely Epoxy resin coating over mid stem structure prevents structure from corrosion. Operating Voltage - 130V to 280V. Maintenance free Can be used for any type of liquid.
Country of Origin : India
Size : 2inch, 3/4inch, 4/5
Type : Motorized Butterfly Valve
Material : UPVC
Color : White
Feature : Casting Approved
Technics : Gear Operated
Power : Electric
Structure : U Section
Port Size : 6cm-20cm
Number Of Way : 2way
Brand Name : Subtech
Application : Water/Gas
Media : Water
Temperature Of Media : 70
...moreMeter DB Control Panel
80,000 Per Piece
2 Piece (MOQ)
Brand Name : Subtech
Material : Galvanized Iron
Phase : Three Phase
IP Rating : IP44
Frequency : 50 Hz
Capacity (A) : Upto 150 Amps
...moreLt Distribution Panel
It is used in electricity supply systems to divide electrical power feed into other circuits. It has a key role in supplying power and protecting permanently installed equipment for building such as power and lighting facilities while providing a protective fuse or circuit breaker for each circuit, in a common enclosure. Features : Manufactured for multiple operations with PMC Technology advantages without any problems like overheating & burning of coil. Manufactured in GI sheets to provide high strength, longer service life, corrosion free, low maintenance cost. Provided with hinges, fixings and locks & fully enclosed switchgear.
...moreLimit switch 10 A. Roller type
74 Per Piece
50 Piece (MOQ)
Usage : industries
Switch Type : Rotary Limit Switch
Pole Throw : SPDT
Switch Configuration : Both
Rated Voltage : 240 VAC
...morefire fighting control panel
4,450 - 100,000 Per Box
1 Piece(s) (MOQ)
Fire Fighters is the controlling component of a fire alarm system. The panel receives information from devices designed to detect and report fires, monitors their operation integrity and provides for automa control of equipment, and transmission of information necessary to prepare the facility for fire based on a predetermined sequence. The panel may also supply electrical energy to operate any associated initiating device, notification appliance, control, transmitter or relay. Features : Fire Fighting Pump control panel with necessary safety features for Hydrant Pump, Sprinkler Pump, Jockey Pump & Booster Pump. Suitable to work in Auto & Manual mode to maintain water pressure in hydrant & sprinkler water line. The Fire Panel receives signal from alarm devices like Pressure Switch and activates motor control devices to provide power to fire pumps and monitor its performance.
Material : Iron, Metal, Mild Steel, Stainless Steel
Condition : New
...moreDigital Current Limiting Device
2,380 Per Piece
10 Piece (MOQ)
Brand Name : SUBTECH
Changeover Source Type : Dual Source
Warranty : 1 year
...moreDG Set Control Panel
25,106 Per Piece
S.S. Power System is one of the well-known manufacturers of Automatic Mains Failure (AMF) Panel including Protection for DG sets. It uses advanced technology to make Genset control easy and trouble-free.AMF Panel keeps the load on when mains fail, the AMF Panel senses this and starts the Genset. Once the Genset is found running, the load is transferred to the Genset supply. When mains resume, the load is transferred back to the mains supply and Gensets stops automatically. In actual operation, various inbuilt timers are used and these are as follows:
Country of Origin : India
Type : Dg Set Control Panel
Application : Control Panel
Color : Grey
Phase : Three Phase
Warrenty : 1 Year
Autoamatic Grade : Fully Automatic
Brand Name : SUBTERCH
...moreThree Phase Automatic Changeover Switch
4,920 Per Piece
25 Piece (MOQ)
Automatic Mains Failure Panel
27,500 - 32,550 Per Piece
Auto main failure panel is used for the automatic operation of the Genset. It monitors the power availability of both “MAINS” and “GENERATOR” automatically, and delivers you the healthy power continuously; on the other hand it will monitor the operation state for Generator while the Generator is running. During abnormal or common faults of generators, AMF Panel will give you both the visual (by LED) and audio signal feedback.Features : Auto Start & Auto Stop the Genset when Mains fails & restores respectively. Cranking standard - three cranking attempts with 15 sec intervals. Auto / Manual mode selector available, automatically changes lines from Mains and Gen Line and vice versa. Mains restoration delay time - 10 sec, start delay time: 3-5 sec. cool down time: 30-40 sec, DG output delay time: 8-10 sec. Low/high Voltage protection, Reverse phase protection (optional) Digital Volt, Amp., Hz. Meters & 5 Indication for Mains, DG and load in Display Contactor Coil Voltage: 180-260 VAC & Pre Magnetic Contactor Coil Voltage- 130-280VAC Availability : 40 Amp. to 500 Amp.
Country of Origin : India
Color : Grey
Voltage : 440V
Condition : New
Finishing : Powder Coated
Phase : Triple Phase
Warranty : 1 Year
Current Type : AC
IP Rating : IP30-50
Mounting Type : Base Mounting
Power Consumption : 2W-5W
Corrosion Resistance : Yes
Number of Poles : 3 Pole
Terminals : 9 Terminal
Relay Type : Dry Filled
Rust Resistance : Yes
Brand Name : Subtech
Material : GPSP
Shape : Rectangular
Certification : CE Certified
Usage : Mines, Factories, Power Plants, Shopping Malls
Specialities : Shocked Proof, High Performance
Size (Inches) : 400x500x150 mm
Overall Dimension : 400x500x150 mm
Relay Height : 40mm
Relay Length : 30mm
Overall Weight : 22 kg
Packaging Type : Carton Box
Soldering Method : PCB
Working Temperature : 55
Density : 32
Ambient Temperature : 50
Thickness : 1.2 mm
Frequency : 50
Max Switching Current : 100 A
...moreAutomatic Changeover Switch
Auto changeover the need for continuous power supply and its reliability has increased rapidly over the years, especially in all those areas where continuous power supply is must. Their complexity has increased as continuous information and communications are needed to control automated process, be in industries, commercial complexes, hospitals, hotels or even modern residences. Automatic Changeover from main supply to stand by supply is vital for all the above kinds of load. In case of both DG Supply as well as mains supply, comes together then priority will be of mains because the automatic changeover will change DG supply to mains. In the event of power failure, the standby power is usually expected to take over automatically. Electrical starting equipment, battery bank and diesel generator are required for the automatic operation. The automatic transfer is achieved mostly by AMF Panels. The process of on-load transfer has to be monitored & controlled for a smooth Changeover and within safety limits of all elements of the system. Features: Operating Voltage 130V to 280V Inbuilt SMPS supply to operate the circuit Simplifies electrical complexity with NFC System LED Indication for MAINS ON & GENERATOR ON Potential free contact for Start/stop of generators (optional) Genset Stop system is inbuilt, especially for Portable Generators Time Delay on generator mode in changeover in higher capadty When main supply is resumed, the connected load is automatically shifted to mains Powder Coated 130 Compact size Wall mounting, Temper proof and maintenance free Microcontroller based technology with Pre-Program interlocking to prevent short circuit. Single Phasing does not affect the overall output: Only the absent phase of mains will fail in output, not all three phases will fail Switch over time for genset to main is very minimum so that even sensitive equipment's do not get "OFF" during the switch over Its unique circuit design enables the relay to be in 'ON' position only while the genset is in use. During main supply the relay remains in 'OFF' position. Due to this the life of changeover gets increase. No Time Delay for output on resumption of Mains Supply whenever DG's not working. In that time Interval as load remain connected to the mains only. (Even in the absence of one or two phase also) DG Supply can/cannot be used at the time of single phasing of Mains supply. (Because some users are satisfied even in single phase to save the diesel cost.) In the Presence of supply in all three phase, load automatically shifts from DG to Mains with a time delay of 5 Sec. But when there is one or two phase supply, Load will not shift from DG to Mains only.
...moreAutomatic Battery Charger
1,720 Per Piece
Our team of quality analysts strictly tests each product against varied quality parameters ensuring zero defects at buyer's end. Be it online payment or offline, we make possible for you to make trade transactions as per your convenience. We offer both offline and online mediums to make payment.Automatic Battery Charger for charging generator battery automatically with LED indications and fault protections. Features : Trickle and boost mode Reverse polarity protection Auto cut-off on full charge Availability Transformer Base Battery Charger : 12/24 VDC SMPS Base Battery Charger : 12/24 VDC
Country of Origin : India
Condition : New
Driven : Electric
Brand Name : SUBTECH
Color : White
Voltage : 12V 6A
Warranty : 1 year
...moreOpening Hours