Vacuum Circuit Breakers
We manufacture quality Rectifier Duty transformers up to 10 MVA capacity in Oil cooled type having various voltage and current ratings as per the relevant IS standard. Besides all standard fittings as specified in IS standard, optional fittings such as low/high frequency, short circuit and overload protections / cutoffs can be provided as per customer’s requirement. Ranging up to 10 MVA Capacity, 33 KV Class 6/12 Pulse having Vector group DYn11 for 6 pulse & DYn11 with DD0 for 12 pulse or as per requirement Voltage Ratios as per requirement Naturally cooled (ONAN) or Forced Air Cooled (ONAF) Transfomers available with & without taps Suitable for diode and thyristor rectifiers to be used for Electrolysis processes Low losses, Heavy Designs than conventional designed transformers to accomodate harmonics generated in the system Accessories / Fittings as desired by Customer In Accordance with IS, IEC, BS and ANSI Standards, others on request
...morestep up step down transformers
We manufacture quality Step Up / Step Down transformers up to 10 MVA capacity in Air/Oil cooled type having various voltage and current ratings as per the relevant IS standard. Besides all standard fittings as specified in IS standard, optional fittings such as low/high frequency, short circuit and overload protections / cutoffs can be provided as per customer’s requirement. Ranging up to 10 MVA Capacity Upto 33 KV Class (HV / LV Voltage Ratio as per requirement) Single / Dual Ratio Three Phase / Single Phase, 50 / 60 HZ Filled with ISI marked Transformer Oil Insulation Class A or as per request Naturally (ONAN) or Forced (ONAF) Air Cooled Conventional or Multi-tap Custom Construction Tanks with Elliptical Tube Radiators / Press Steel Radiators or Corrugated Tanks Available with OLTC, RTCC & AVR Low Losses Accessories / Fittings as desired by Customer In Accordance with IS, IEC, BS and ANSI Standards, others on request
...moreservo voltage controllers
We are leading manufacturers of Industrial Voltage Controllers offering Variac / Dimmer Type and Linear / Rolling Contact Type Servo Voltage Controllers or LT Automatic Voltage Regulators (LT AVR) conforming to IS: 9815/1994 with latest amendments or as per customer's specifications. These are designed to overcome and control voltage fluctuations due to diverse loading duties and line losses arising in transmission & distrbution network. Controlled & Constant Voltage Reduced Failure Rate of Electrical Equipments Improvement in Power Factor & Reduction in MDI Reduction in Down Time / Maintenance Expenses Energy Saver - Reduction in Power Consumption 80% Depreciation under Income Tax Act being an energy saving equipment Short Payback Period Compatible to D.G Sets Servo Voltage Controllers are virtually required at all such places where controlled and constant voltage is one of the most important requirements and are suitable where breakdown due to voltage fluctuation results in heavy financial losses such as Hospitals, Laboratories, Various Life Saving & Testing Equipments, Pharmaceuticals, Research Institutes, Defense, Telecommunications, Air Conditioning, Data Processing, Electronics based Industries, Educational Institutes, Food Processing Units, Paper plants, Footwear and Leather Industries, Cement Plants, Textile Industries, Moulding Units, Hotels, Farm Houses, Offices and Residences/ Housing Apartments, etc. Variac / Dimmer Type Linear / Rolling Contact Type Input Voltage Range (3 phase) Output Voltage (3 phase) Average Correction Rate Response Time Freq. Range Efficiency Temperature Rise Type Operating Mode Oil Filled Type Dry Type Contol Panel Protections (optional as per customer's requirement)
...morerectifier duty transformers
We manufacture Cast-Resin Dry Type Transformers upto 3000 KVA; 33KV class as per Indian & International Standards i.e. IS, IEC & ANSI etc. Our transformers are design to withstand high humidity, temperature, adverse service conditions & short circuit levels & all these make our products an ideal choice. Designing, selection of raw materials, state of the art – Casting Plant, in house testing facility & highly experienced manpower make our products very reliable & cost competitive. Maintenance FreeDue to encapsulation of coils with cast resin the coils dimensions are stable & no coil tightening is required to maintain the short circuit strength. Also no check of oil level and electrical insulation/oil is required. Non- HygroscopicIn cast-resin dry-type transformers, the complete encapsulation of primary and secondary winding in epoxy resin prevents penetration of moisture into windings. The cast resin offers very good protection against adverse ambient conditions. These transformers can work without disruption of service at 100% humidity. Non Inflammable and Self ExtinguishingDue to high quality insulation material the transformer is practically non-inflammable by an electrical arc, special fire protection measures are not required. Resistant against Temperature FluctuationThe insulation material used is glass fibre reinforced with epoxy resin of class 'F' which can withstand wide temperature variation. Higher Impulse StrengthContrary to the conventional dry type transformers the cast coil transformers are better in respect of impulse voltage withstand strength. Higher Short Circuit StrengthHigher dynamic short circuit withstand strength as compared to oil immersed and conventional dry type transformers because of fibre glass reinforced epoxy encapsulation. Free of Partial DischargesNo partial discharges can occur during operation. Instant SwitchingDue to the high grade insulation material, coils are non hygroscopes & the transformer can be switched on directly without pre-drying even after a long period of service interruption. No Leakage or Pilferage of OilAs cast resin transformers are solidly cast, problem associated with oil filled transformers like oil leakage and pilferage of oil is completely avoided. Saving in SpaceThese transformers are generally smaller in dimensions and lesser in weights. The construction and installation cost for the sub-station can be reduced by adopting dry type transformers. Eco-FriendlySince no oil is used in these transformers, there are no chances of contamination of ground water due to oil leakage. Saving in Civil work cost and LT cablesWithout fire or danger of explosion, it is possible to place the transformers near to the load centre. Also, these transformers do not need construction of special fibre brick walls or oil pits, which reduces the overall civil works. Additionally, since LT cables are not required, thers is also saving in cost on account of expensive cable laying works. Public Places and High rise buildings Shopping Malls Railway Fixed traction installation Underground Cranes Seaports and Offshore platforms Drives Gas ,Turbines , Generators and Drilling system Solar Application Mining Ranging up to 3000 KVA Capacity Up to 33 KV Class Three-Phase, 50 / 60 Hz Single / Dual Ratio Naturally Cooled (AN) or Forced Air Cooled (ANAF) Sheet metal enclosure with vents for air circulation IP-23 or as per customer's requirement Accessories / Fittings as desired by customer Insulation Class F / H, others on request Applicable Standards IS:11171, IEC:60726 Tap Changer: Tap Links / On Load Tap Changer (OLTC) with RTCC & AVR Temperature Sensors for alarm and trip protections
...morePower Distribution Transformer
We manufacture quality transformers up to 10 MVA capacity that have low losses & are suitable for continuous rating upto its full capacity. Besides standard fittings as specified in the IS standard, optional fittings such as LV Bus Duct, LV cable box, HV cable box, Buchholz Relay, Marshalling box, Magnetic oil level gauge, HV Disconnecting chamber, WTI & OTI with (Trip & Alarm contacts) can be provided as per customer’s requirement. Technical Specification Ranging up to 10 MVA Capacity HV 33 / 22 / 11 KV or as per request LV 11 / 6.6 / 3.3 KV or as per request Single / Dual Ratio Three Phase, 50 / 60 HZ Filled with ISI marked Transformer Oil Insulation Class A or as per request Oil Natural Air Natural (ONAN) Off Circuit / On Load Tap Changer with RTCC & AVR Tanks with Elliptical Tube Radiators / Press Steel Radiators or Corrugated Radiators Heavy Designs with Low Losses Accessories / Fittings as desired by customer In Accordance with IS, IEC, BS and ANSI Standards or as per request
...moreLoad Break Switches
We manufacture Load Break Switches (LBS) in three pole, manual / motorised operated upto 33KV range. Our LBS is simple but robust design with trouble free mechanism. These are used in application like transformer switching, ring main gears (RMG), condensers, etc. We offer LBS that can be make / break the normal rated current and make the short circuit current. The design of Load Break Switch is user friendly and easy in operation reliable function. Load Break Switches are manufactured in accordance with IS 9920 / IEC 265. Available in both Indoor / Outdoor version and Extensible Metal clad hence no access to live parts No arc chute hence minimal maintenance Maintenance free mechanism Separate HT / LT Compartments Compact design with aesthetic look Rated Voltage Rated Current Permissible Service Voltage Rated Short Time Current Rated Making Peak Type of Break Rated Insulation Level / Peak Rated Frequency No. of Poles No. of Breaks / Pole Width x Depth (mm) Height (mm) - Indoor Height (mm) - Outdoor 12 KV 400/630 A 10-12 KV 26.3 kA 65 kA Air Break 28KV/75KV 50 Hz 3 Single 600 x 1100 1600 1825 24 KV 400/630 A 22-24 KV 26.3 kA 65 kA Air Break 50KV/125KV 50 Hz 3 Single 1000 x 1500 2200 2425 36 KV 400/630 A 33-36 KV 26.3 kA 65 kA Air Break 70KV/170KV 50 Hz 3 Single 1500 x 1600 2500 2725 Load Break Switch + Earth Switch(LBS+ES) Load Break Switch + Earth Switch with CBCT& Earth Leakage Relay (LBS+ES+ELR) Load Break Switch + HT HRC Fuse+ Earth Switch (LBS+FT+ES) Ring Feeder orIncomer Ring Feeder orIncomer with Earth Leakage Relay Tee-Off Feeder orOutgoing Feeder
...moreIsolation Ultra Isolation transformers
We manufacture quality Isolation & Ultra Isolation transformers up to 2000 KVA capacity in Air/Oil cooled type having various voltage and current ratings as per the relevant IS standard. These Isolation transformers are of double wound with electrostatic shielding in between primary, secondary & magnetic core. EC grade copper, high grade CRGO & best quality insulation material is used resulting into low temperature rise. The main features of these transformers are to isolate the high voltage transients, spike noise, EMI interference and DC leakage. These are designed for good common mode noise rejection, coupling capacitance, DC galvanic isolation and good voltage regulation. These can also be designed for step down or step up or 1:1 ratio. Besides all standard fittings as specified in IS standard, optional fittings such as low/high frequency, short circuit and overload protections / cutoffs can be provided as per customer’s requirement. Ranging up to 2000 KVA Capacity Available in 1 : 1 Ratio or as per request Step Down / Step Up Voltage Ratio Three Phase / Single Phase, 50 / 60 HZ Air Cooled (Dry Type) / Oil Cooled (ONAN) Insulation Class F/H in case of Air Cooled / Dry Type & Class 'A' in case of Oil Cooled Low Losses Accessories / Fittings as desired by Customer In Accordance with IS, IEC, BS and ANSI Standards, others on request
...moreHt Automatic Voltage Regulator
It is seen that despite best efforts by many electricity boards / supply undertakings, due to diverse loading duties arising in transmission and distribution network, voltage at consumer's end is never constant. This low/high voltage is applied to all electrical machines like Transformers, Motors, etc., hence causing loss in substantial electrical energy. Besides voltage fluctuations also play havoc by damaging expensive, sophisticated, CNC/PLC controlled equipment, lighting, elevators, etc. Therefore arising a need to conserve energy as power tariff is ever increasing. We manufacture HT-AVR that are designed to overcome & control voltage fluctuations due to diverse loading duties & line losses arising in transmission & distribution network. These are designed for balanced as well as unbalanced loads & input voltage supplies. HT-AVR operates ON Load directly on the HT line and provides a stabilized HT output voltage +/-1% that is fed to the step down transformer resulting in constant/stable LT output. The line diagram is given below showing the same. HT-AVR supplies rated Stabilized Voltage to the Transformer, thereby the utilization of the transformer will be up to full rated capacity and is protected from High/Low voltage fluctuations Low losses as voltage fluctuation is removed from the system Single unit of HT-AVR can be connected to multiple Distribution Transformers Reduction in Breakdown of Electrical Equipment Power Saving (Reduction in Power Bills) Improvement in power factor and reduction in MDI Better efficiency in plant Being categorized as a power saving device, the payback period for the cost of our HT-AVR is from 12-15 months depending upon the input voltage and no. of working hours of the plant Key Features Compact Design Minimum Power Losses Better Efficiency Low Input ranges can be stabilized in High Ratings Low Response Time Low Maintenance Trouble Free Operation Long Service Life Space Saving Reduced Installation Cost Reduction in Electricity Bill
...moreFurnace Duty Transformers
We manufacture quality Furnace Duty transformers up to 10 MVA capacity in Oil cooled type having various voltage and current ratings as per the relevant IS standard. Besides all standard fittings as specified in IS standard, optional fittings such as low/high frequency, short circuit and overload protections / cutoffs can be provided as per customer’s requirement. Ranging up to 10 MVA Capacity, 33 KV Class 6/12 Pulse having Vector group DYn11 for 6 pulse & DYn11 with DD0 for 12 pulse or as per requirement Input - 33, 22, 11, 6.6, 3.45, 3.3, 0.415 KV or as per requirement Output - 415, 433, 460, 480, 525, 575, 2x575, 2x600 V or as per requirement Naturally cooled (ONAN) or Forced Air Cooled (ONAF) Transfomers available with & without tap Filled with ISI marked Transformer Oil Low losses, Heavier Designs than conventional designed transformers to accomodate harmonics generated in the system Suitable for induction heating and melting applications Accessories / Fittings as desired by Customer In Accordance with IS, IEC, BS and ANSI Standards, others on request
...moreFully Automatic Line Voltage Correctors
We manufacture fully Automatic Line Voltage Correctors that are designed to overcome & control voltage fluctuations due to diverse loading duties & line losses arising in transmission & distribution network. Our ALVC conforms to IS: 8448/1989 reaffirmed 2003. Advantages Ultra Slim Power Saver Space Saver Wall Mounted New Generation Voltage Stablizer Integrated Circuits (IC) based, to increase reliability Elegant Structure to Enhance Your Decor Consists of Toroidal transformers manufectured using latest German Technology . Produces least leakage magnetic flux compared to any other transformer, Any type of interfering fields tend to cancel in a Toroidal core compared with other types of transformers. Feature Intelligent Time Delay for Auto Restart / Manual Start Automatic Cut-off For High/ Low Input Voltage Digital Indications : Input Voltage / Output Voltage/ Output Current (Amp.)
...moreCoverter Duty transformers
We manufacture quality Coverter Duty transformers up to 10 MVA capacity in Oil cooled type having various voltage and current ratings as per the relevant IS standard. Besides all standard fittings as specified in IS standard, optional fittings such as low/high frequency, short circuit and overload protections / cutoffs can be provided as per customer’s requirement. Ranging up to 10 MVA Capacity, 33 KV Class 6/12 Pulse having Vector group DYn11 for 6 pulse & DYn11 with DD0 for 12 pulse or as per requirement Voltage Ratios as per requirement Three Phase, 50 / 60 Hz Suitable for Variable Frequency Drives (VFD), Adjustable requency Drives (AFD), & Variable Speed Drives (VSD) applications Transfomers available with & without taps Naturally cooled (ONAN) or Forced Air Cooled (ONAF) Low losses, Heavy Designs than conventional designed transformers to accomodate harmonics generated in the system Accessories / Fittings as desired by Customer In Accordance with IS, IEC, BS and ANSI Standards, others on request
...moreCompact Sub Station
We manufacture various modules of Indoor/Outdoor type Compact Sub-Stations upto 2500 KVA capacity, 33KV class of transformers with HT/LT switchgears. The Compact Sub-Station (CSS) is also known as Unitised Sub-Station (USS) or Packaged Sub-Station (PSS). The Compact Sub-Staton is a compact arrangement, which replaces conventional sub-station arrangement consisting of Load Break Switch / Vacuum Circuit Breaker, Transformer, Distribution Panel, Lightening arresters mounted on a pole structure or on a platform. CSS is designed, keeping in mind the personal safety & aesthetics, considering HT equipment is located in high density urban places. It is a pre fabricated secondary sub-station consisting of three compartments (i.e.) H.V.Compartment which houses Vacuum Circuit Breaker (VCB) or Load Break Switch (LBS), the transformer compartment which houses dry type /oil cooled transformers & the LV compartment which houses ACB, MCCB, SFU etc. as per client's requirement. All components are housed in an enclosure which protects the equipment against environmental hazards & unauthorized access . The electrical equipments are cooled by natural ventilation. Fully compartmentalized design Easy to install, operate & require very Less Maintenance Cost Effective & Space Saving Reduced Electrical Losses as CSS can be installed near the load centre A high degree of Safety & operational reliability is achieved by HT & LT switchgear with protective relays Reduction in logistic cost as the CSS is delivered as a single unit Tailored Configuration to meet customer requirement Due to the enclosed construction, it avoids Bird hit, human / animal contact which may lead to fatal accident and disruption of power supply Aesthetically enhanced look & designed to suit the site topography, which gives pleasing appearance No separate room is required Can be installed Indoor & Outdoor Load Break Switch with fusetrip & earth switch mechanism, shunt trip coil, HT HRC fuses Vacuum Circuit Breaker with metering & protection using current/potential transformers & relays Ring Main Units consists of Load Break Switches/Vacuum Circuit Breakers combination Oil Filled Transformer Dry Type Transformer LT Control Panel with ACB & MCCB SFU with metering CSS are ideally suited for residential and commercial complexes as it can be placed on ground floor or basement or roof top of the high rise buildings Mainly used by Power Utilities, Multiplex, Hotels, Hospitals, Shopping Malls, Software Parks, Airports & Residential complexes etc.
...moreAutomatic Power Factor Control Panel
We offer Panels with diverse specification options for a highly customzed panels upto 6300 amps having fixed and draw out types, including single/double front type. The LT Panels conform to IS 8623-part 1:1993 & IEC 439-1:1985. Our panels are designed to withstand high humidity, temperature, ambient service conditions and short circuits levels & these make our panels an ideal choice. Our panels provides superior control & protection of low voltage power equipment & circuits in utility, industrial, commercial installations involving generators, motors, feeder circuits and distribution. An electrical distribution board that receives power from generator or transformer and distributes the same to various electronic devices and distribution boards. Such panels are used in industries both for internal and external use and therewfore are quite rugged to withsatnd different climatic conditions. Our LT Panels are designed to work with low electricity consumption that makes them cost effective. These panels work between two or more different power sources like DG sets to manage power supply. Synchronization helps in making different DG sets behave as a virtual single unit and eliminates sub-division of total load. It helps in transferring loas from one unit to another as during service period, so that the unit requiring service can be easily shut off. In this way the critical load need not be interrupted and there is no production loss. During low load we can run any single unit and synchronize more units as the load increases automatically. Features Fully compartmentalized design Easy to install, operate & require very less maintenance Cost Effective & Space Saving A high degree of Safety & operational reliability is achieved Tailored Configuration to meet client's requirements Aesthetically enhanced look & designed to suit client's requirement Designed to meet temperature rise limits Safety Completely enclosed bus bar chambers Shrouded links in feeder compartments Dust & vermin proof construction Bus bar constructions to withstand high fault levels upto 70 KA
...moreBe first to Rate
Rate ThisOpening Hours