Automated Hot Block workstation
Vulcan is the first automated workstation combining the two essential steps of sample preparation -Digestion and Work-up. It is the only true automation accepting samples and returns prepared autosampler racks ready to be analysed.
...moreviscothermostats
LAUDA viscothermostats are the solution to thermostating all glass capillary viscometers. With their wide temperature range, the control heads of Proline and ECO meet the high requirements of viscosity measurement (ASTM D445, ISO 3105, and DIN 51562). High degree of transparency and homogeneous lighting guarantee good inspection of the measurement processes. Numerous advancement options (e.g. magnetic stirrer, additional cooler, temperature sensors, and software) optimize the range of applications possible. The new Viscocool and Viscotemp viscothermostats are sensible add-ons to the Proline PV and ECO ET. The Viscotemp models supplement the robust stainless steel thermostats with a very good price-performance ratio. The new Viscocool 6 is equipped with integrated Peltier cooling which enables thermostating at up to 15 °C below room temperature in compliance with standards. Application examples: Standard-compliant thermostating of different models of glass capillary viscometers Thermostating of automatic viscometers as all-around systems Manufacture of dilution series with magnetic stirrers
...moreUV Sterilising PCR Workstation
The PCR Workstation Pro provides the ideal environment for biomolecular experiments sensitive to contamination: UV Air Recirculator module for elimination of aerosol contaminants during experiments UV germicidal tubes eliminate nucleic acid contaminations between experiments The PCR Workstation Pro provides sufficient space and electrical connections to make a really useful and practical working area. 8 mm thick, ethanol resistant safety panels made of Makrolon® effectively protect against UV irradiation.
...moreUniCen MR
Microprocessor controlled For centrifuge tubes and bottles, Microtiter plates, Tissue-culture tubes, Microliter tubes, etc. Maximum capacity: 4 x 200 ml 12 angle rotors, 3 swing-out rotors, 1 microhematocrit rotor Speed: 500 – 18,000 rpm, in steps of 100 rpm g-force (RCF): 30,065 x g, in steps equivalent to 100 rpm Timer: up to 60 min, in 1 min increments, on request up to 999 min. HOLD for longer runs PULSE for short runs 9 acceleration and deceleration ramps Maintenance free, brushless induction drive Stainless steel chamber with additional inner guard ring Overspeed detection, imbalance detection and cut-off Motorized lid lock, automatic lid opening, emergency lid lock release LCD display for both current and preset values of speedg-force, time and temperature
...moreUniCen M
Microprocessor controlled For centrifuge tubes and bottles, Microtiter plates, Tissue-culture tubes, Microliter tubes, etc. Maximum capacity: 4 x 200 ml 12 angle rotors, 3 swing-out rotors, 1 microhematocrit rotor Speed: 500 - 16,000 rpm, in steps of 100 rpm g-force (RCF): 23,755 x g, in steps equivalent to 100 rpm Timer: up to 60 min, in 1 min increments, on request up to 999 min. HOLD for longer runs PULSE for short runs 9 acceleration and deceleration ramps Maintenance free, brushless induction drive Stainless steel chamber with additional inner guard ring Overspeed detection, imbalance detection and cut-off Motorized lid lock, automatic lid opening, emergency lid lock release LCD display for both current and preset values of speedg-force, time and temperature (temperature only in refrigerated model UniCen MR)
...moreUniCen HR
Microprocessor controlled For centrifuge tubes and bottles, Microtiter plates, Tissue-culture tubes, Microliter tubes, etc. Maximum capacity: 4 x 200 ml 13 angle rotors, 3 swing-out rotors, 1 microhematocrit rotor Speed: 500 – 30,000 rpm, in steps of 100 rpm g-force (RCF): 70,484 x g, in steps equivalent to 100 rpm Timer: up to 60 min, in 1 min increments, on request up to 999 min. HOLD for longer runs SHORT for short runs 9 acceleration and deceleration ramps Maintenance free, brushless induction drive Stainless steel chamber with additional inner guard ring Overspeed detection, imbalance detection and cut-off Motorized lid lock system, automatic lid opening, emergency lid lock release Display for both current and preset values of speedg-force, time and temperature, fast One-Knob data entry Cooling at standstill and fast cooling program OPtional touchpad-panel with advanced options
...moreTVT 2 - Lauda
Drop by drop more precise: The LAUDA Drop volume Tensiometer TVT 2 The LAUDA Drop volume tensiometer expands the options for measuring the dynamic surface tension and interfacial tension of liquids. In a unique process, the system can be controlled under Windows with minimum loading of the computer, even when multi-tasking. New functions, such as individual drop measurement of up to 100 drops are now possible. The LAUDA Tensiometer TVT 2 consists of a measurement desk and a control unit. The core of the electronic component is a microprocessor that controls the discharge speed, the counting of the encoder pulses, and the communications. LEDs and pictograms indicate the current status of the unit. Keys are provided for positioning the syringe plunger even in offline mode. During online operation, an RS 232 interface enables communication with the operating PC. Application examples: Wetting agent concentration in galvanic baths Screening tests of emulsifiers Additional applications that cannot be handled or can only be handled incompletely with other devices:Characterisation of the dynamic behaviour of surfactant molecules at the surface and interface within seconds or hours. High-precision measuring of interfacial tension in a very wide range down to 0.1 mNm. Measurements on highly volatile andor toxic substances, through gas-tight sealing of the system. High viscosity and skin-forming liquids can also be measured easily and rapidly.
...moreThermalox
The ThermaloxTMEnvironmental is equipped, as standard, with features many manufacturers treat as extras – and you can measure solids The Thermalox instruments utilize our Model 8000 XYZ autosampler. This gives maximum flexibility and allows a high degree of automation. Calibrants can be made up automatically; sparging, dilutions and sample agitation can easily be carried out. The standard vial rack holds up to 88 glass or disposable plastic vials, with or without lids. It can be chilled and we are happy to provide racks to suit special requirements. By using a special aspiration step, samples containing particulate can be automatically agitated, ensuring that a representative sample aliquot is aspirated from the vial. Catalytic thermal oxidation. The only way to measure 'real' samples containing particulate or difficult to oxidise materials Standard Deviation better than 20ppb on low level Carbon Standard Deviation better than 10ppb on low level Nitrogen Upper Range Limit greater than 50,000ppm for TOC Detection Limit of better than 40ppb for TOC and 10ppb for TNb Analysis time less than two minutes per replicate Complete recovery, including Suspended Solid fraction Handles salts and particulate easily Holds up to 88 samples Complete washing between samples ensures no carry over Totally software driven from a Windows™ based platform Automatic preparation of calibration standards
Features : Carrier gas generation fitted as standard on TOC – no need for bottled gases,Automatically prepares its own calibrants – eliminates human error
...moreLauda iVisc Viscometers
Fully automatic, space-saving, mobile and easy to operate The new LAUDA iVisc is a capillary viscometer for the automatic measurement and evaluation of kinematic viscosity in accordance with DIN 51562 and ASTM D445. Furthermore, it opens up the possibility of calculating polymer data, e.g. SV-, IV- and K-values and the dynamic viscosities of oils, lubricants and beverages. The iVisc can be employed in any test laboratory where viscosity values have to be determined. Other wide-ranging application examples can be found in quality control in polymer manufacture, in compounding and in the manufacture of plastic prefabricated parts. Application examples: Determining the viscosity number, intrinsic viscosity (average molar mass) and other parameters of technical polymers such as PA, PET, PBT, PE, PP and PVC in accordance with EN-ISO 1628, ISO 307 for the quality control of plastics Measuring absolute viscosities of engine oils and other lubricants in accordance with ASTM D445, viscosity index in accordance with ISO 2909 at 40 °C and 100 °C
...moreThe Compact TD 3 Tensiometer
With integrable stirring Peltier thermostating unit. Precise surface and interface tension at constant temperature. The new LAUDA Tensiometer TD 3 is used for the automatic measurement of surface tension and interfacial tension as well as for the determination of the density of liquids. The surface materials of the TD 3 are chemically resistant and suitable for almost all fields of application. An important application for the LAUDA TD 3 is the determination of interfacial tension in transformer oils for assessing the ageing, and consequently the insulating properties of transformer oils. Other typical applications are found in the beverage, food and petrochemical industries, with surfactant manufacturers and in pharmaceutics.
...moretensiometers
The TD 1 C units, whose technology has been completely revised and which bear a new design, offer even easier handling due to the handy remote control Command which has proven itself with LAUDA thermostats and measuring instruments. State-of-the-art processor technology allows extended documentation options. The sample stage of the easy to handle tensiometer can be manual adjusted.The measuring values are only displayed on the remote control. The evaluation of these values can be printed on an optional protocol printer. So the TD 1 C is a very flexible and highly precise measuring instrument.
...moreSingle-Use Laboratory Bioreactor
The EDF-5.4 monoblock can be adapted for single use bioreactor control. For example, we have expierence in application of single use vessels from CerCell (Danmark). CerCell has configurable vessels of different volumes (0.5 to75 liters). These vessels are equipped with all necessary accessories to provide fermentations of different microbial cultures. An important advantage of these vessels is the possibility to achieve high mixer rotation speeds. For example, 7.5 liter bioreactor, equipped with 3 ruchton turbines, can achieve mixer rotation speed up to 1500 rpm. In SUB it is possible to apply both single use and sterilizable pH and pO2 sensors. The application of SUB has following advantages: Decreases the risk of contamination; Eliminates the necessity to acquire and maintain the infrastructure for the processes (cleaning and sterilisation), which can be critical for validation; Simplifies and reduces validation costs; Reduces the costs of labor expenditures for the preparation operations (assembling - disassembling, cleaning and sterilization); The possibility to develop the fermentation processes according GMP requirements.
...moreShaking Water Bath
Quiet Shaking Mechanism Universal Rack takes Flask from 50 ml up to 2L PID Temperature Control up to 99 °C Shakes from 20 to 250 rpm Digital Speed Control Two Models with Bath Capacities 22L, 30L Stainless Steel Bath (SUS304) Quiet Shaking Mechanism - Electronically controlled shaking mechanism, provides noiseless reciprocal motion and precise speed control from 20 to 250 rpm, perfect for long time use High Quality Stainless Steel, corrosion resistant (SUS304) bath Over Temperature Protection, and over current protection capability ensure, user safety
...moreShaking Incubator
Digital PID Control - Provides precise temperature control from 10°C to 80°C, Speed control 0 to 400 rpm touch – sensitive membrane type Keypad with timer Safety and Convenience Over temperature and current protection, leakage breaker Ensure our safety Universal Spring Rack - Which can accommodate various sized flasks and tube racks easy to attach and remove from the shaking plate Shaking Mechanism - Electronically controlled shaking mechanism provides quiet orbital motion precise speed control and digital display Shaking Motion can stop automatically when door is opened.
...moreRM 200 Touch Universal rheometer
RM 200 TOUCH Universal rheometer with carry case Rheology : A Breeze ! Carry out your flow curves directly on your RM200 TOUCH rheometer, without needing to be connected to a computer, for precise quality control that is both simple and effective Specifications: TYPE OF INSTRUMENT: Rotating rheometer with imposed speeds SPEED RANGE: Unlimited number of speeds between 0.3 and 1500 rpm TORQUE RANGE: From 0.05 to 30 mNm | From 0.005 to 0.8 mNm (LR VERSION) | From 0.05 to 40 mNm (AC 115 VERSION) TEMPERATURE: The RM 200 TOUCH has a PT100 sensor which indicates temperatures between -50 °C to + 300 °C ACCURACY: +- 1 % of the full scale REPEATABILITY: +- 0,2 % VISCOSITY RANGE: 1 - 540,000,000 mPa·s depending on the measuring geometry used DISPLAY: 7" Touch screen DISPLAY SETTINGS: Viscosity | Speed | Torque | Temperature | Time | Measuring geometry | Level of sensitivity | Date hour | Choice of viscosity units: cP or mPa·s | Language: FrenchEnglish DISPLAY SETTINGS IN FLOW MODE: Plastic Viscosity | Yield Value | Thixotropy | Choice of model: Newton – Bingham – Casson - Ostwald SECURITY AND CONFIDENTIALITY: An "operator" function allows you to enter a username for your instrument. This user must then be identified using a 4-digit code. There is also a protected mode that locks your measurement conditions
...moreRM 100 TOUCH Universal viscometer
Our expertise ensures your results are reliable You can programme your measurement methods directly using RM 100 TOUCH's touch screen, and back up your data so you can analyse or export them
...moreRM 100 Touch Portable viscometer
RM 100 TOUCH PORTABLE Universal PORTABLE viscometer with carry case Save your data of measurements on site Carry out measurements directly while being produced and save your results on a USB stick thanks to the Portable RM 100 Touch. Specifications: TYPE OF INSTRUMENT: Rotating viscometer SPEED RANGE: Unlimited number of speeds between 0.3 and 1500 rpm TORQUE RANGE: From 0.05 to 30 mNm | From 0.005 to 0.8 mNm (LR VERSION) TEMPERATURE: The Portable RM 100 TOUCH has a PT100 sensor which indicates temperatures between -50 °C to + 300 °C. ACCURACY: +- 1 % of the full scale REPEATABILITY: +- 0,2 % VISCOSITY RANGE: 1 - 540,000,000 mPa·s depending on the measuring geometry used DISPLAY: 7" Touch screen DISPLAY SETTINGS: Viscosity | Speed | Torque | Temperature | Time | Measuring geometry | Level of sensitivity | Date hour | Choice of viscosity units: cP or mPa·s | Language: FrenchEnglish SECURITY AND CONFIDENTIALITY: An "operator" function allows you to enter a username for your instrument. This user must then be identified using a 4-digit code. There is also a protected mode that locks your measurement conditions
...moreRM 100 Touch Gel Timer
RM 100 TOUCH GEL TIMER Viscometer – Gel timer Determine the gel times of your resins and scalable products The RM 100 TOUCH GEL TIMER is ideal for monitoring viscosity changes in your products up to a solid state. Specifications: TYPE OF INSTRUMENT: Rotating viscometer | gel timer SPEED RANGE: Unlimited number of speeds between 0.3 and 1500 rpm TORQUE RANGE: From 0.05 to 40 mNm TEMPERATURE: The RM 100 TOUCH GEL TIMER has a PT100 sensor which indicates temperatures between -50 °C to + 300 °C. ACCURACY: +- 1 % of the full scale REPEATABILITY: +- 0,2 % VISCOSITY RANGE: 100 - 5,000,000,000 mPa·s depending on the speed used. DISPLAY: 7" Touch screen DISPLAY SETTINGS: Viscosity | Speed | Torque | Temperature | Time | Measuring geometry | Level of sensitivity | Date hour | Choice of viscosity units: cP or mPa·s | Language: FrenchEnglish SECURITY AND CONFIDENTIALITY: An "operator" function allows you to enter a username for your instrument. This user must then be identified using a 4-digit code. There is also a protected mode that locks your measurement conditions.
...morerheometers
Carry out your flow curves directly on your RM200 TOUCH rheometer, without needing to be connected to a computer, for precise quality control that is both simple and effective,DISPLAY SETTINGS: Viscosity | Speed | Torque | Temperature | Time | Measuring geometry | Level of sensitivity | Date hour | Choice of viscosity units: cP or mPa·s | Language: FrenchEnglish,SECURITY AND CONFIDENTIALITY: An "operator" function allows you to enter a username for your instrument. This user must then be identified using a 4-digit code. There is also a protected mode that locks your measurement conditions
...moreRAYPA MBC compact digestion system
Programmable auto-start. Nine user free programs. All programs include up to 18 steps for temperature and incubation time
...moreRAYPA fibre extractor
RAYPA fibre extractor. Weende and Wijstrom method for raw fibre. Van Soest method for dietetic, acid detergent and neutral fibre.
...moreRaypa Fiber Extractor
RAYPA fat extractor
RAYPA fat extractor. Method Soxhlet and Randall. Fat extraction system using several solvents, as Randall method.
...moreRAYPA fat cold extraction system
RAYPA cold fat extraction system, pre-treatment for F-6. Suitable for many extraction solvents. 6 simultaneous samples.
...moreBe first to Rate
Rate This