Vicat Softening Apparatus
75,000 Per Unit
1 Unit (MOQ)
Vicat Softening point apparatus
Get Price Quote
Vicat Softening Point Apparatus - Vicat softening temperature of plastics is the temperature at which a standard flat-ended indenter penetrates one millimeter into the surface of the material under test under a specified load. The test is conducted by placing a test specimen taken from the sample under test on a flat platform inside a liquid bath and applying compression load over its upper face through a flat-ended indenter. The load is applied by placing a dead weight on the upper end of the indenter. After the test specimen attains the temperature of the bath, the bath temperature is increased gradually till the indenter penetrates by exactly 1 mm into the test specimen. The bath temperature in ºC at which this happens is reported as the Vicat Softening Temperature of the sample under test. The Vicat Softening Point Apparatus (High Temperature Model) consists of a specimen support, weights, a deflection measuring device, and an immersion bath. The specimen support consists of a circular supporting plate on which the specimen is kept and a loading plate having a bush for guiding a vertical rod carrying a hardened indenting tip. The two plates are joined together with spacer rods of same material (brass) as indenting rod so that they have identical co-efficient of linear expansion.
Best Deals from Vicat Softening Point Apparatus
VICAT SOFTENING POINT
Get Price Quote
The VICAT softening temperature (VSP) test is a standard test used to assess the temperature at which a flat tipped needle of specified dimensions penetrates into plastic specimen a specified distance under a given load.
Vicat Softening point apparatus
3,500 Per Piece
Features : Portable Easy installation Crack resistance Precisely engineered Excellent heat softening properties Proper functioning Details : ESPM GS IEC IAS
Vicat Softening point apparatus
Get Price Quote
We believe in keeping transparency in the transactions and thus we offer an invoice to the clients stating all the necessary details. We undertake both online and offline payment processing methods. As one of the leading Suppliers, we keep our quality in synchronization with our reputation and offer the best Vicat Softening point apparatus to the buyers.
Vicat Softening point apparatus
Get Price Quote
VSP is used to determine the deflection temperature limit for specific application and comparing the heat softening characteristics of thermoplastic material at constant load in oil up to 300º C with specified rate of rise. Plastic materials being heat sensitive in nature has a lot of bearing on its thermal environment for its performance. Though their behavior in thermal conditions is very complex, some simple yield tests are used to predict it’s behavior and performance in given conditions. This is one of such yield point very commonly employed with such demanding application.
Vicat Softening point apparatus
Get Price Quote
The H.D.T V.S.P Apparatus offered by us is widely used as Heat deflection Testers and Vicat softening Point. This apparatus is essentially used to test the variations in the temperature & softening point of the specimen used. Available in various models with a number of stations, these apparatus are manufactured as per the ASTM D 1525 & D648 standards.
Vicat Softening point apparatus
Get Price Quote
Designed and built to cover multiple International Testing Standards the Ray-Ran Advanced HDT/Vicat Apparatus utilises microprocessor technology to accurately determine the deflection and softening point characteristics of all thermo plastic test specimens.The HDT/Vicat apparatus allows for multiple simultaneous testing of samples depending on the amount of test stations available, either 2 or 4. The simple manually operated raise and lower function of the test stations ensure easy access to the test sample supports for sample loading and retrieval before and after each test.Each test station is fitted with a PT100 platinum resistance thermometer which accurately records the temperature next to the sample under test to 0.1°C and an electronic displacement transducer which measures the sample displacement to 0.01mm as standard or to 0.001mm as an option. The on board microprocessor ensures test result accuracy and repeatability and the built in liquid crystal display (LCD) provides simple on screen instructions reducing user error. Test parameters are easily selected using the onboard membrane keypad. A simple data selection process and yes/no prompts make the operating procedure very simple to undertake. The microprocessor’s temperature control function ensures the ramping rates of either 50°C/h or 120°C/h are kept within the specified test standard requirements as well as performing non standard ramp rates to customers own specific needs. Test temperatures of 300°C are easily achieved and to ensure optimum safety at higher temperatures the Nitrogen Blanket option is recommended.The methods of testing available on the apparatus areHDT - Heat deflection / distortion testA standard sized test specimen is subjected to a bending stress, whilst the temperature is raised at a uniform rate. The temperature at which the specified deflection occurs is measured and recorded. Testing is carried out in accordance with the ISO 75 (parts 1, 2 and 3) and ASTM D648 Test Standards.For this test a required fibre stress of 0.45, 1.8, or 8.00 MPa is easily selected. Custom fibre stresses can also be managed by the microprocessor if required. The unique binary weight system is used to apply the required fibre stress to the test sample and is automatically calculated by the microprocessor based on the sample size and span supports. Temperature ramp rates, sample size, span and deflection values are also easily entered into the testing parameters of each station. The HDT span supports of 100mm or 64mm are easily adjusted on each tool station to suite your testing method of Flat wise or Edgewise sample testing.Each machine is supplied with HDT test nibs with 3mm radius which are easily attached to the load displacement rods for testing in accordance with relevant international test standards.Vicat (VST) - Softening point testA specified needle (indentor) penetrates a specified distance into a sample with a specified load, whilst the temperature is raised at a uniform rate. The temperature at which the sample was penetrated is recorded as the Vicat Softening Temperature (VST). Testing is carried out in accordance with the ISO 306 and ASTM D1525 Test Standards.For this test penetration loads are easily selected via the microprocessor for use with the single loading weights of 10 N and 50N. The supplied cylindrical indentor test nib with 1mm² surface area is attached to the load displacement rod for sample testing in accordance with relevant testing standard.The apparatus is supplied as standard with an integrated solenoid operated cooling system which is automatically activated after each test. It can be connected to either a standard water supply or to the optional chiller unit for improved heat reduction. The integrated cooling coil ensures rapid heat loss back to start temperature conditions within a short time period increasing production.The self calibration feature of the apparatus ensures that the test results remain accurate. Unique calibration plugs are supplied with each machine which simply plug into the PRT socket for you to carry out the calibration procedure. Test results are downloaded to the supplied file capture software via the RS232 serial connector and are displayed in tabular format. Results can also be saved as .CSV files which can be opened with Microsoft Excel for data manipulation and report presentation. If required the optional thermal printer can be supplied and fitted to the apparatus for direct results printout.Built with operator simplicity in mind, its ease of operation and high accuracy makes the Ray-Ran Advanced HDT/Vicat Apparatus ideal for product development and quality control within production, research and development labs and teaching institutions and should more than meet all of your testing requirements. Technical Specification HDT/Vicat testing enabled Manual Raise/Lower of test stations Advanced microprocessor control 2 sample test stations Digital temperature control Temperature range to 300°C Resolution +/- 0.01mm Oil bath stirrer Solenoid operated cooling system Integrated safety thermostat HDT Heads (1 per station) Vicat Nibs (1 per station) Standard Fiber Stress 0.45, 1.8 or 8.00 MPa User defined fiber stress for HDT testing available Standard Vicat penetration of 0.1mm or 1.00mm User defined penetration depth for Vicat testing available Temperature resolution +/- 0.1°C Temperature ramp rates of 50° or 120° C/hr User defined ramp rates available HDT span supports 64mm or 100mm Bath capacity 8 litres RS 232 connection RS232 Cable Windows File Capture Software Fully traceable certificate of calibration Product user manual CE declaration certificate 1 year return to base warranty 110v – 240v 16amp Optional Ancillaries Binary HDT Test Weights (1 set required per station) 1.00Kg Vicat Test Weight (1 required per station) 5.00Kg Vicat Test Weight (1 required per station) Displacement Transducer 0.001mm Light Weight Load rods to test to .45 MPa Heat Transfer Medium 5ltrs Nitrogen Blanket Air to Nitrogen Extractor Thermal Printer Thermal Printer Paper Water Chiller unit
Vicat Softening point apparatus
Get Price Quote
Vicat Softening Point Apparatus is used for determining the softening point of Polythene. The Vicat Softening Point is the arithmetic mean of the VSP of the test specimens. The apparatus consists of a heating bath, sample holding stand and a stirring rod. The heating bath is a double walled vessel. A glass stirring rod, one 1 kg weight and one EKE 072 Dial Gauge 0.01 x 25 mm are supplied. The rate of increase of heat is controlled by a Sunvic Energy Regulator supplied alongwith the apparatus.Details Product Code: EKE 901 Standrad : IS:2750 Suitable for operation on 220V, 50 Hz, Single Phase, AC supply
Vicat Softening Point Test Apparatus
Get Price Quote
Backed by a team of highly skilled engineers, Kant Plastology engaged in providing a wide range of VICAT SOFTENING POINT APPARATUS. The compact and elegant look of apparatus contains high efficient S.S. 304 tubular heating system for appropriate rate of rise of heat and stirrer motor to create uniform heating in test chamber. The offered apparatus has highly precise temperature control through micro processor based double display digital PID controller. Kant Plastology procures accurate weight, rigid test assembly, test needle & calibrated Dial gauge to conduct the test.
Vicat Softening point apparatus
Get Price Quote
NAUGRALABS LABORATORY PRODUCT NAME: VICAT SOFTENING POINT APPARATUS FOR TESTING LAB NaugraLabs Laboratory Product Code: NLE-Export-370011 Description and Specification for Lab Tenders Vicat Softening Point Apparatus For Testing Lab Workshop. Vicat Softening Point Apparatus - Vicat softening temperature of plastics is the temperature at which a standard flat-ended indenter penetrates one millimeter into the surface of the material under test under a specified load. The test is conducted by placing a test specimen taken from the sample under test on a flat platform inside a liquid bath and applying compression load over its upper face through a flat-ended indenter. The load is applied by placing a dead weight on the upper end of the indenter. After the test specimen attains the temperature of the bath, the bath temperature is increased gradually till the indenter penetrates by exactly 1 mm into the test specimen. The bath temperature in ºC at which this happens is reported as the Vicat Softening Temperature of the sample under test. The Vicat Softening Point Apparatus (High Temperature Model) consists of a specimen support, weights, a deflection measuring device, and an immersion bath. The specimen support consists of a circular supporting plate on which the specimen is kept and a loading plate having a bush for guiding a vertical rod carrying a hardened indenting tip. The two plates are joined together with spacer rods of same material (brass) as indenting rod so that they have identical co-efficient of linear expansion. The indenting rod is fitted with a disc near its top to place the dead weight on. Two circular dead weights are provided to enable loads of 1 kg or 5 kg to be applied on the test specimen. A dial gauge is provided above the rod to measure the indentation of the tip into the test specimen by gauging the movement of the rod. civil lab equipments manufacturers Plastic Films Testing Lab equipment manufacturers,exporters and Plastic Films Testing Lab suppliers
Vicat Softening point apparatus
Get Price Quote
Backed by a team of highly skilled engineers, Kant Plastology engaged in providing a wide range of VICAT SOFTENING POINT APPARATUS. The compact and elegant look of apparatus contains high efficient S.S. 304 tubular heating system for appropriate rate of rise of heat and stirrer motor to create uniform heating in test chamber. The offered apparatus has highly precise temperature control through micro processor based double display digital PID controller. Kant Plastology procures accurate weight, rigid test assembly, test needle & calibrated Dial gauge to conduct the test. Specification
Vicat Softening point apparatus
Get Price Quote
Determination of the temperature at which a standard indenter penetrates 1mm into the surface of a plastics test specimen under one of the loads specified under uniform rate of heating. Rate of rise of temp. 50 + 50C per hr. 120 + 120C
Vicat Softening point apparatus
Get Price Quote
Product Code: EKE 901Standrad: IS:2750 Suitable for operation on 220V, 50 Hz, Single Phase, AC supply Vicat Softening Point Apparatus is used for determining the softening point of Polythene. The Vicat Softening Point is the arithmetic mean of the VSP of the test specimens. The apparatus consists of a heating bath, sample holding stand and a stirring rod. The heating bath is a double walled vessel. A glass stirringrod, one 1 kg weight and one EKE 072 Dial Gauge 0.01 x 25 mm are supplied.The rate of increase of heat is controlled by a Sunvic Energy Regulator supplied alongwith the apparatus.
Vicat Softening point apparatus
Get Price Quote
Ring & Ball (Softening Point) Test Apparatus is used for determination of softening point of bituminous materials. Softening point is that temperature at which the specimen under test becomes soft enough to allow a steel ball of specific dimensions to fall a required distance under test conditions.
Vicat Softening point apparatus
Get Price Quote
Vicat softening point apparatus These products are appreciated by the clients in domestic as well international market due to their durability, easy operations, compact designs and robust construction.
Vicat Softening point apparatus
Get Price Quote
We manufacture Vicat Softening point apparatus etc.
Vicat Softening point apparatus
Get Price Quote
Vicat Softening point apparatus
Vicat Softening Point Apparatus High Temperature
Get Price Quote
Vicat Softening Point Apparatus High Temperature, Multi- Cell Aging Oven