BHARANI MEDICAL AND SURGICAL EQUIPMENTS Panjagutta, Hyderabad, Telangana

  • X-Ray Film processor tabletop

    X-Ray Film processor tabletop

    Request for Price

    Processing machine for X-ray films from 13x18 cm. 18x24 cm.24x30 cm.30x40cm.35.6x35.6 cm. 35x43cm. Capacity at least 60 films per hour Standard Equipment: Processor + set of 3 replenish bottles Accessories: Water supply connection with shut-off valve , Filter , Light-tight cover , Processor stand Automatic stand-by mode. Automatic film detection Power Requirements : 220 VAC ±10 % 50 Hz .

    ...more
    Get Best Price
  • X-ray Film Viewer

    X-ray Film Viewer

    Request for Price

    X-ray film illuminator (viewer) . 2 fields . Wall-mount diffuse, uniform, flicker free illumination transparent spring-loaded film retainers shall grip lightly and firmly without obscuring top edge details screen shall be recessed into the cabinet to help keep the interior dust free and eliminate side light spill the film retainers shall always operate effectively maintaining an even pressure across the full width of the illuminator. Direct starting , luminous source : daylight command and control on front side. Bipolar switch with pilot lamp wall fixations shall be provided for . Cord , local plug power supply : 220v50hz ce; ec marked us fda; iso certification

    ...more
    Get Best Price
  • X-Ray Unit Universal

    X-Ray Unit Universal

    Request for Price

    Universal, remote controlled universal unit processor controlled, mixed cassette’s radiography and digital fluoroscopy screening system. Overhead tube on the freely moving tube arm without floor mounted column. The system to be suitable for standard skeletal and radiographic examinations, including lateral exposures and oblique beam projections fully automatic under table spot film device for cassette radiography with extensive range of cassettes, grids and attachments for image intensifier. Free cassette exposures on table, floor, wheelchair or gurney. Table. Tilt: motor driven, +90º to -15º, automatic stop in horizontal position height: approximately 85 cm. Tabletop outside dimensions: length approximately 200cm,width approximately 80cm radiolucent: not less than 190cm x 55cm. Longitudinal travel: motor driven, at least 160 cm transverse travel: at least 20 cm patient weight: at least 200 kg. Tube assembly. Max. Exposure voltage : 150 kv anode heat dissipation rate at least 30 kw for small focus and 60 kw for large focus anode heat storage capacity at least 500 khu dual focus 0.6 mm and 1 mm complete filtration w  2.5 mm al focus-film distance (sid) fixed variable : 115cm 150cm. 115cm and 150cm must be set by motor driven with adjustment speed oblique projections: max.-40º-+40º ( sid 115cm.) and -35º-+35º (sid 150cm), automatic parallax compensation between cassette and image intensifier input screen in central ray

    ...more
    Get Best Price
  • Ultrasound (3 probes)

    Ultrasound (3 probes)

    Request for Price

    Wide dynamic range digital front-end the 12-bit ad converter multi-beam processing. Image display modes b: gray-scale imaging, m,d: spectral doppler (pw,hprf pw), flow: color doppler and power flow imaging, dual b, b and m, b and d, b(flow), dual b (flow), m(flow), b(flow) and m(flow), b(flow) and d, triplex mode: b, flow and pw doppler simultaneous real-time display, dual dynamic display (ddd): b and b (flow) simultaneous real-time display, tdi (tissue doppler imaging)-available on electronic scanning probes. Request function: in multi-mode display, it is possible to select one image for full screen display. Dms (integrated data management system) measurement and analysis. General measurements on b-mode image on m-mode image on spectral doppler on bd-mode image on b(fiow) mode image obstétrical measurements & calculations gynecological measurements & calculations peripheral vessels analysis urological measurements & calculations abdominal measurements report functions data communication function preset function characters and graphic displays probe connectors standard active connectors: 2 connectors dummy connector for rest: 1 connector viewing monitor 15-inch diagonal color liquid crystal display with brightness and contrast controls acoustic power 0 to 100%, changeable environmental requirements temperature: +10 to +40 degrees c relative humidity: 30 to 75% power requirements: 220v 50 hz. Probes general abdomen obgyn 2.5-6.0 mhz. Small parts, pv (steered linear) 5.0-10.0 mhz. Adult heart (harmonic echo) 2.1-3.8 mhz.

    ...more
    Get Best Price
  • Gastroscope (With halogen light source)

    Gastroscope (With halogen light source)

    Request for Price

    Optical System : Field of view: at least 100°° Depth of field: at least 4 to 100 mm Distal end : Outer diameter: not more than 10mm. Bending Section Range of tip bending: not less than Up 210°, Down 90°, Right 100°, Left 100° Insertion tube : Outer diameter: not more than 13.3mm Working length: not less than 1025mm. Length markings Instrument channel : Inner diameter: not less than 2.8mm. Light source Halogen technology shall provide a high light intensity of at least 150W. Variable light intensity. Fast and easy bulb change during operation : In case of a bulb failure immediate switch to the second bulb with the reverser shall be possible.Adjustment of brightness and power with buttons and switches on the front panel. Shall be connectable with conventional telescopes, fiberscope. Shall be adaptable to all endoscopic procedures Optionally , an automatic built-in swivel mechanism will bring the spare halogen bulb into working position. Technical Data : Halogen , 150 watts , Halogen, 2 pieces Manual switch , 2 x 150 W , 24 V Power Supply : 220 VAC 50 Hz . Standards CE; EC Marked US FDA; ISO certification

    ...more
    Get Best Price
  • Colonoscope (With halogen light source)

    Colonoscope (With halogen light source)

    Request for Price

    Optical System : Field of view: at least 120° Depth of field: 5 –÷100 mm. Distal end : Outer diameter: not more than 13mm. Bending Section Range of tip bending: not less than Up 180°, Down 180°, Right 160°, Left 160° Insertion tube : Outer diameter: not more than 13.3mm Working length: not less than 1680mm. Instrument channel Inner diameter: not less than 3.2mm. Light Source Halogen technology shall provide a high light intensity of at least 150W . Variable light intensity Fast and easy bulb change during operation : In case of a bulb failure immediate switch to the second bulb with the reverser shall be possible Adjustment of brightness and power with buttons and switches on the front panel. Shall be connectable with conventional telescopes, fiberscope, Shall be adaptable to all endoscopic procedures Optionally , an automatic built-in swivel mechanism will bring the spare halogen bulb into working position. Technical Data : Halogen , 150 watts , Halogen, 2 pieces Manual switch , 2 x 150 W ,24 V Power Supply : 220 VAC 50Hz . Standards CE; EC Marked US FDA; ISO certification

    ...more
    Get Best Price
  • Electrocardiograph 3 channels

    Electrocardiograph 3 channels

    Request for Price

    Recording ecg leads: 12 standard leads recording channels: 31 user selectable lcd display of ecg lead switching: manual and automatic. Sensitivity, mmmv: 5, 10, 20. Calibration signal: automatic and manual. Diagnostic frequency range 0.67–150 hz or better filters for mains frequency, low frequency, muscle artefact, high frequency recorder: recording method: thermal paper recording speed, mmsec: 25 50 user selectable channels acquired simultaneously:1 3 user selectable channels printed simultaneously:1 3 user selectable other features: portable mains and internal rechargeable battery operation battery operating time, minimum: 90 min. Power requirements: 220 v, 50 hz accessories: 1. Patient cable 2. 6 chest limb electrodes 3. 4 limb electrodes 4. 4 strap electrodes 5. 6. 1 bottle ecg gel 7. 2 rolls of paper or z-fold 8. Carry bag standards ce; ec marked us fda; iso certification

    ...more
    Get Best Price
  • Operating theatre light (5 spotlights)

    Operating theatre light (5 spotlights)

    Request for Price

    Surgical lighthead with five projectors , ceiling suspended light intensity (ec) at least150 000 lx color rendering index (general) ra 96 color rendering index (red) r9 89 light field size 15 – 30 cm. Colour temperature 4200º kelvin working range without focusing approximately 70 – 140 cm power supply 220 vac, 50 hz adjustable light intensity power supply , 220v50 hz. Power stabilizer shall be supplied this equipment shall be supplied with all necessary fixation gears to the building structure replacement bulbs (5) and sterilizable handles (5) shall be supplied standards ce; ec marked us fda; iso certification accessoriesspares : 5 bulbs per unit 2 handles per unit

    ...more
    Get Best Price
  • Operating Table

    Operating Table

    Request for Price

    Operating table designed for carrying out treatments, dressing interventions and operations of general surgery and traumatology all exposed metallic parts shall be made from stainless, acid proof steel. The table base shall be mobile and shall have central brakes back rest and leg rest inclination angle, kidney elevator, trendelenburg and reverse-trendelenburg positions and height adjustment of the table top shall be activated by electro - hydraulic system the table top shall be translucent for x-rays with 5 separate sections table top length approximately 2000 mm table top width approximately 600mm minimal height of the table 750mm maximal height of the table 1100mm indicatively trendelenburg at least 25 reverse trendelenburg at least 25º lateral tilt at least 18º back rest inclination angle at least +55º to -25º head rest inclination angle at least 45º up head rest inclination angle at least 20º down power requirements 220 vac ±10 % , 50hz accessories: anaesthetic screen with clamp with telescopic tubes : 1 body restraint strap with clamp : 1 padded shoulder supports : 2

    ...more
    Get Best Price
  • Operating Table (Multifunction, electric/hydraulic driven)

    Operating Table (Multifunction, electric/hydraulic driven)

    Request for Price

    Operating table for carrying out treatments, dressing interventions and operations of general surgery (3-4 surgeries daily). All exposed metallic parts shall be made from stainless, acid proof steel. The table base shall be mobile and shall have central brakes back rest and leg rest inclination angle, trendelenburg and reverse- trendelenburg positions and height adjustment of the table top shall be activated by electro - hydraulic system the table top shall be translucent for x-rays with 5 separate sections table top length approximately 2000 mmtable top width approximately 600mm minimal height of the table 750mm maximal height of the table 1100mm indicatively trendelenburg at least 25º reverse trendelenburg at least 25º lateral tilt at least 18º back rest inclination angle at least +55º to -25º head rest inclination angle at least 45º up head rest inclination angle at least 20º down power requirements 220 vac ±10 % , 50hz accessories: anaesthetic screen with clamp with telescopic tubes : 1 body restraint strap with clamp : 1 padded shoulder supports : 2 padded leg support with swivel type clamp : 2 padded arm rests 450 -500 mm long with two arm clamps : 2 padded lateral support with universal attachment clamp : 2 padded rubber mattresses with anti microbial agent incorporated into all components that assists in prohibiting growth of bacteria & fungi and easy to clean and maintain and of at least of 1” thickness : 2 x5 sections head rest , i.v drip stands attachable to the table environmental factors: the unit shall be capable of being stored continuously in ambient temperature of 0 - 50deg c and relative humidity of 15-90% the unit shall be capable of operating continuously in ambient temperature of 10 -40 deg c and relative humidity of 15-90% standards ce; ec marked us fda; iso certification

    ...more
    Get Best Price
  • Anesthesia trolley (anesthesia machine with ventilator and monitor)

    Anesthesia trolley (anesthesia machine with ventilator and monitor)

    Request for Price

    Anesthesia machine used for delivering anesthesia agents to patient during surgery procedures. The complete set-up shall also ventilate the patient patient monitoring system ecg, etco2, pulse oximeter and airway pressure, nibp, rectal&skin temperature. The full system shall be completed with : anaesthesia gas delivery system, o2n2ocompressed air . Circle absorber system. Precision vaporiser for halothane anaesthesia ventilator patient circuit anesthesia gas delivery system: shall have provision for delivery of oxygen, nitrous oxide and medical air with pressure gauges. Oxygen and nitrous oxide should be linked either mechanically or pneumatically to ensure a minimum of 25% oxygen delivery at all times to avoid delivery of hypoxic mixture. Shall have audio-visual oxygen failure warning system with nitrous oxide cut off. Shall have back bar iso pin type to attach vaporizer easily. Flowmeter oxygen : 0÷2; 2÷10 litresmin, minimum range flowmeter n2o : 0÷2; 2÷10 litresmin, minimum range with safety mechanism (hypoxic link) or similar flowmeter , medical air 0÷10 litresmin. Shall be supplied with necessary attachments for use of the breathing circuits (ruben , bains, jackson-rees or magill ) construction : shall have top shelf to keep monitors and a tabletop with drawers to keep anaesthetic drugs, equipments etc. Castor wheels should be durable , moisture resistant and antistatic the anaesthesia machine frame shall be made of rust proof materialstainless steel or sheet steel protected with epoxy-paint standard circle absorber system shall have adjustable pressure limiting valve, breathing circuit pressure measuring device. Shall have a bagventilator selecting valve integrated onto the absorber. Facility to attach oxygen sensor shall have co2 absorbent chamber canister (soda lime )

    ...more
    Get Best Price
  • Syringe Pump

    Syringe Pump

    Request for Price

    Syringe driver for parenteral infusions , in wards, op, icu's and during transportationtransfer single channel. Shall accept up to 60cc syringes , non-captive self checking of electronics with audible call back on locked-out controls tamper and fluid resistant design . Abs casing (impact-resistant ) shall be fitted with iv rod, adjustable height with 4 hooks.mobile on 5 star stand with castors internal rechargeable battery rate: 0.1 to 99.9 ml ( in 0.1 ml steps) indicatively total volume infused: 0.1 to 999.9 ml precision : +-3%.stipulated syringes occlusion release shall give minimum bolus effect syringes : 10 types at least of luerlock type 1060ml.syringes,+ specific choice pause infusion facility alarmssafety infusion nearly complete infusion complete occlusion system malfunction syringe unlocked plunger disengaged low battery protection against leakage current:type cf.equipment protection against electric shocks:class ii.equipment safety features: error coding (event log) rate change through audible stop switch audible call back on locked-out-controls automatic detection of syringe volume minimum bolus on occlusion release at any selected rate communication : rs232c interface electrical: electrical: class ii (double insulated)

    ...more
    Get Best Price
  • Electrosurgical Unit

    Electrosurgical Unit

    Request for Price

    Hf electrosurgical unit shall be used to execute monopolar and bipolar surgery in many fields of application where high precision and reliability are essential outputs of cut, coagulate and blend maximum output 300 w for monopolar cut activation : double pedal switch which may be used for the monopolar and bipolar functions . Hand-switch handle bipolar electrode with pedal switch or with automatic startstop system ( for coagulation only) control the unit shall stop automatically in case of internal error which shall be identified on display and with audible alarm memorization : user shall be able to use at least 4 working programs safety : neutral plate safety circuit shall control connections and contacts of neutral plate with tissues: defective contact shall be notified with visual alarm and immediate reducing of power output circuit : floating - protected against defibrillator interferences . Shall have hf leakages less than 150ma through each electrode power supply : 220vac, 50hz cooling: convection without fan accessories : single-use two button handle , autoclavable handle shall be provided with a 3 pins socket that shall fit majority of bipolar electrosurgical units operative foot-switch (usable as alternative to handle) reusable neutral plate kit of 10 short autoclavable electrodes electrode wire - straight electrode wire - angled 45° electrode bend - 0 4 - straight electrode bend - 0 8 - straight electrode hook - angled 45° electrode wire 1 mm.- angled 45° electrode straight slip-knot - straight electrode angled slip-knot - straight electrode ball point - 0 3 mm. - angled 45° electrode ball point - 0 3 mm. – straight bipolar forceps : 6 forceps shall be provided with a standard european connection straight forceps - 18 cm. (7")

    ...more
    Get Best Price
  • Operating instrument set

    Operating instrument set

    Request for Price

    1 operating scissors, 170 mm, straight, blunt-blunt points 1 2 operating scissors, 140 mm, straight, sharp-blunt points 1 3 operating scissors, 140 mm, curved, sharp-blunt points 2 4 dissecting scissors, curved, for deep surgery, 230 mm 2 5 operating scissors, 140 mm, curved, blunt-blunt points 4 6 operating scissors, curved, blunt-blunt points, 170 mm 2 7 operating scissors, 140 mm, curved, hardened, blunt-blunt points 1 8 sharp tips scissors, curved, 160 mm 1 9 dressing forceps, standard pattern  1502,5 6 10 dressing forceps, standard pattern  2002,5 4 11 surgical forceps, 150x2,5 8 12 surgical forceps, 1 x 2, 200x2.5 mm 4 13 abdominal depressor, 285 mm, blade 70 mm wide 1 14 tissue forceps, 265 mm, straight 5 15 tissue forceps, 256 mm, curved 5.

    ...more
    Get Best Price
  • Defibrillator

    Defibrillator

    Request for Price

    The following specifications define a portable, lightweight ; battery or accumulator operated automated external to treat patients requiring basic life support weight of complete unit, excluding batteries or accumulator , shall permit easy transport . The overall dimensions shall enable easy storage and portability the casing shall be constructed to withstand the standard operating conditions in a physician’s office andor hospital. The device must also with stand the harsh operating conditions associated with ambulance use. The unit shall be safe to use both for the operator and the patient. Defibrillator the device shall utilize biphasic waveform technology as the primary energy delivery option and shall include automatic and manual modes the biphasic waveform shall allow for escalating energies up to at least 200 joules safety: internal discharge of energy if no discharge is effected. Internal self-testing and fault recognition. Required power 200-240v 5060 hz weight not more 10kg accessories : full standard accessories set-up shall be supplied standards ce; ec marked us fda; iso certification

    ...more
    Get Best Price
  • ventilator icu

    ventilator icu

    Request for Price

    Care ventilator, for use on pediatricinfant- adult patients with graphics display monitor. Breath types: vc, pc, vtpc modes ( in each breath type): acmv, simv, spont, spontaneous breath choices: ps, vtpc. Features: inspiratory time at least 0-3 sec with optional pause inspiratory flow at least 3-140 lmin pressure support: at least 0 to 45cm h2ombar tidal volume: at least 10-800ml resp.rate: at least 6-150bmin pressure limit: 0 to 80cmh2ombar i:e rate: 1:4 to 4:1 trigger pressure or flow fio2: 0.21 to 1.00 peepcpap: 0 to 45 cmh2ombar leak compensation standby condition: allows setting to be preset and circuit check tests to be performed prior to starting ventilation open exhalation valve (bprv): onoff for biphasic pressure release ventilation event history log: records 1000 events; alarm & settings compliance compensation: onoff graphical display of respiratory parameters must be mounted over the mobile medical air compressor. Power requirements 220 vac ±10%, 50hz. Internal rechargeable battery provides an minimum. 60 minutes for complete ventilator function. Accessories : medical air compressor humidifier 1 tube set, adults 1 tube set, children 1 humidifier chamber o2-connecting tube 5.0 m 1 air-connecting tube 5.0 m humidifier : heating power with safety thermostat and indication of operating status 1 circuit , adults with patient tubes , water traps, y-piece,mask elbow, catheter connector 1 circuit , children with patient tubes, water traps, y-piece,mask elbow, catheter connector 1 carriage articulated bracket for rail o2-cell without housing

    ...more
    Get Best Price
  • Pulsoximeter

    Pulsoximeter

    Request for Price

    Real-time spo2% oxygen saturation range (%spo2) measurement range at least 70-99% accuracy (%spo2) ±2% at100%~80%, ±3% at 80%~70% real-time heart rate (bpm) pulse measurement range 30-250 bpm accuracy ± 1 bpm at 30~250 bpm display spo2,pulse rate, pulse signal wave, maxmin setup (spo2% bpm) power requirements internal rechargeable battery providing an operating time of at least 8 hours compact design for easy transportability accessories: 3 rolls of paper operation manual 1 adult reusable finger sensor 1 neonate sensor standards ce; ec marked us fda; iso certification 21 patient monitor, icu 7.

    ...more
    Get Best Price
  • Patient Monitor, ICU

    Patient Monitor, ICU

    Request for Price

    Patient monitor that shall draw cardiograms, measures blood pressure (invasive or not-invasive type), respiration values, temperatures at two spots, oxygen saturation in arterial blood ( spo2 ), and pulse rate ( hr ) . May be used to monitor patients on the transportation by using batteries, and the measured information on patient's condition shall be displayed in wave forms along with numerical values. Displayscreen display : colour tft display , screen diagonal curves and measured values : not less than 25.00cm . Up to 6 curves as well as numerical fields brightness: can be manually adjusted sweep speed : shall adjuste to 6.25, 12.5, 25 and 50 mms display pixels: at least 1024x768 monitor interfaces r-sync: for defibrillator , each r-wave shall be clearly identified , staff call: remote alarm via alarm adapter rs-232: as computer interface mainsbattery operation mains operation: shall be via built-in power supply battery operation: via integrated battery or charging console . Battery operating time: approx. Up to 4 hrs at least power supply : 220 v ac ±10%, automatic change-over power failure buffer : for trend values, system expansion software updates via interfaces monitoring parameters shall include : ecg, resp, ibp, nibp, spo2, pulse rate , dual-temp s-t segment synchronized detection and analysis graphic and tabular trends of all parameters for at least 96 hours 20-mn minimum ecg real time waveform and parameters storage and review shall be able to be connected with a central monitor station

    ...more
    Get Best Price
  • Patient Monitor, anesthesia

    Patient Monitor, anesthesia

    Request for Price

    Patient monitor that shall draw cardiograms, measures blood pressure (invasive or not-invasive type), respiration values, temperatures at two spots, oxygen saturation in arterial blood ( spo2 ), and pulse rate ( hr ) , end tidal co2 (etco2) . May be used to monitor patients on the transportation by using batteries, and the measured information on patient's condition shall be displayed in wave forms along with numerical values. Displayscreen display : colour tft display , screen diagonal curves and measured values : not less than 25.00cm . Up to 6 curves as well as numerical fields brightness: can be manually adjusted sweep speed : shall adjuste to 6.25, 12.5, 25 and 50 mms display pixels: at least 1024x768 monitor interfaces r-sync: for defibrillator , each r-wave shall be clearly identified , staff call: remote alarm via alarm adapter rs-232: as computer interface mainsbattery operation mains operation: shall be via built-in power supply battery operation: via integrated battery or charging console . Battery operating time: approx. Up to 4 hrs at least power supply : 230 v ac ±10%, automatic change-over power failure buffer : for trend values, system expansion software updates via interfaces monitoring parameters shall include : ecg, resp, nibp, spo2, pulse rate ,dual-temp and etco2 s-t segment synchronized detection and analysis graphic and tabular trends of all parameters for at least 96 hours 20-mn minimum ecg real time waveform and parameters storage and review shall be able to be connected with a central monitor station inner high-definition thermal dot matrix recorder optional, w

    ...more
    Get Best Price
  • Oxygen Concentrator

    Oxygen Concentrator

    Request for Price

    Compact and easy to transport oxygen concentrator ( mobile on castors ) the oxygen concentrator shall feature a dual-head compressor. One head producing. Capacity : 1 to 5 lmn of o2 at 90% minimum at maximum flow pressure-compensated flowmeter shall permit use of long canula while maintaining accurate flow setting. Safety alarms: audible and visual : power failure , restricted flow , , low o2 pressure-relief valve and thermal protection of the compressor double-insulated unit , two-prong plug flame-retardant cabinet sound level (ansi): 50 db average fixed humidifer port and recess shall prevent bottle and connector breakage power requirements: 220 vac,50 hz accessories : o2 tubing , 3 face masks ( adult , infant , new born ), humidifier , set of filters standards ce; ec marked us fda;

    ...more
    Get Best Price
  • Gynecology services

    Gynecology services

    Request for Price

    Manufactured from chrome plated steel tube, three sections with independent manual controls and Trendelenburg position. Top is upholstered with washable plastic material and flame retardant. Complete with padded Goepel leg-holders and S.S. bowl. Knock down construction.

    ...more
    Get Best Price
  • Fetal Monitor

    Fetal Monitor

    Request for Price

    Ctg or fetal monitor for recording and analyzing the fetal heart rate (fhr) on beatto- beat basis and the uterine contraction with doppler -us transducer and taco transducer. Portable handheld ctg monitor. Compact and battery operated, shall allow patients to be continuously monitored anywhere . Color display shall show the ctg data presented in standard format for easy interpretation. Fetal signals shall be easily located using the wide angle transducers with contractions stress being monitored by an external pressure transducer. Audio signals of each fetal heart are available on selection by the user through the built in audio system. The user will have control over the audio volume, audio fetal channel, chart recorder speed, toco zero, and event mark via the units front panel push buttons. Directional and watertight ultrasound and tocograph with color-coded transducers for single and twins transducer: multi element wide angle range: 30 to 240 bpm power output: < 20mwcm2 toco transducer: real time uterine activity (contractions) trace on standard scale format digital autocorrelation shall provide accurate and reliable fhr traces a pre-cut, non-fray elasticised belt with buckle shall enable easy transducer positioning for more accurate traces in difficult monitoring situations clinical event marker & automated foetal movement detection . Trace annotation comprehensive patient database shall store over 500 patient records (30 minutes traces) in internal memory of fhr, toco , foetal movements with unlimited data storage on plug-in pcmcia memory cards computer interface 3 wire rs232 thermal printer for common ctg paper speeds: 1,2,3, cmmin paper: z-fold pre-printed chart scale the grid and the fhrua trace shall be printed simultaneously , ensuring printing accuracy and preventing potential errors in interpretation due to paper drifting or pen

    ...more
    Get Best Price
  • Scale for newborn children

    Scale for newborn children

    Request for Price

    Capacity-0-15 kg Graduation-10 gr. Precision-+- 10 gr. Washable surface Body with 6V 20W Halogen for 220V, 50 Hz. Quadruple revolving nosepiece. Sturdy,base with supportive rubber feet. With low position, coaxial coarse and calibrated fine focus control, with graduation reading 2 microns per division. Total focusing 40 mm

    ...more
    Get Best Price
  • Microscope Binocular

    Microscope Binocular

    Request for Price

    Body with 6V 20W Halogen for 220V, 50 Hz. Quadruple revolving nosepiece. Sturdy,base with supportive rubber feet. With low position, coaxial coarse and calibrated fine focus control, with graduation reading 2 microns per division. Total focusing 40 mm. Condenser adjustable. Built-in Power supply , halogen bulb adjustable. Double layer mechanical specimen stage. Dust cover, blue filter, immersion oil and instruction manual included. 2 pcs. 6V 20W halogen bulbs included. Binocular Head, 30° inclined, 360° rotatable, Interpupillary Distance 55 – 75 mm Objectives: ACHRO 4x0.10 ACHRO 10x0.2 ACHRO 40x0.65, spring loaded ACHRO 100x1.25, Oil, spring loaded

    ...more
    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Retailer
  • Secondary Business Type Manufacturer / Exporters / Wholesale Suppliers
  • Year of Establishment 2000
  • No. of Employees 50 - 100
  • Annual Turnover Rs. 25 to 50 Crore Approx.
  • Ownership Type Partnership

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
Bharani Group of Companies is leading manufacturer & exporters of medical equipment, stainless steel hospital hollowares & hospitals equipment. The company offers the widest & most comprehensive range of quality surgical & hospital equipment specializing in autoclaves, instruments sterilizer, dressing drums, instruments tray, kidney trays and bedside accessories. Its products are at par with international quality standard, processed with state of art technology, plant & equipment. The spirit, dedication, technical experience/skills and business acumen of Bharani Group of Companies in manufacturing hospital & surgical equipment, tool and machinery has lead the brand to the path of progress and continued achievements, of course, with the persistent support of our customer and committed hard work of employees. The company has a unique blend of highly experienced personnel and young & dynamic professionals, specializing in their respective fields. They strive hard to ensure to supply quality products at low rates and within the mutually settled delivery schedule, paying due attention to the requirements of packaging and packing. In order to maintain a unique identify, we never try to compete with others, so nobody can compete with us.
At present the company is engaged in the manufacture and marketing of all types of surgical & medical equipment products. With vast experience and considerable expertise, we at Bharani Group specialize in the design, development and manufacturing of technologically advanced electronic medical healthcare instruments for medical institution, hospital and clinics. Our production division facilitated with world-class macheneries and world-class technical team with high efficiency! Our goal is to provide the safest, economical & most advanced health care range worldwide. Our products are manufactured with quality materials in our technologically advanced plants. We continuously upgrade our manufacturing assets with up-to-the-minute equipment and computerized macheneries. The ideal materials and designs are chosen specifically for each product manufactured. We strongly believe that each of our products must meet the stringent specifications.The main aim is to expand our business and promote Indian manufacture worldwide. We have successfully established ourselves as a distinguished organization because of our premium quality products, timely services and cost-effectiveness. Our products are supplied to Government/Private Hospitals, Corporate Hospitals, Medical Colleges and Medical Institutes.The attributes behind our success are state-of-the-art production facilities, quality management system, extensive R&D and customer oriented approach. Furthermore, we are dynamic enough to meet the ever changing requirements of global markets. Our Quality standards and Commitment of our words are highly appreciated by the customers.
Read More »

Contact Information

BHARANI MEDICAL AND SURGICAL EQUIPMENTS

  • Manager
  • Nims Hospital Road, Model House lane, Punjagutta.Hyderabad, Telangana - 500082., Panjagutta

Find Popular Fetal Monitors Dealers in Hyderabad

top