Static Voltage Stabilizer
With Very High Speed of Correction provides perfectly stable output even under severe conditions of unbalanced voltage conditions. Ideal to protect the electrical and electronic equipments from high and low voltage.
...moreStatic Voltage Regulator
ervomax India Ltd takes pride in providing excellent solutions to all kinds of Power problems. We recognize your company as one of the leaders in the field of Electronic Industry. We understand your aims of bringing out the best products in present competitive market. While you focus on manufacturing quality products, Servomax would like to support you by ensuring that your sophisticated tools and equipments are maintained and operated at maximum efficiency by taking care of all kinds of power problems that may damage or cause your equipment to perform at low efficiency.
...moreServo Stabilizer
with Relay / Contactor High voltage protection Low voltage protection with MCB Overload protection Short circuit protection
...moreServo Controlled Voltage Stabilizer
provides perfectly stable output even under severe conditions of unbalanced voltage conditions. Ideal to protect the electrical and electronic equipments from high and low voltage.
Operating Frequency : 47 to 53 Hz
Correction Rate : 60 / 30 / 25V per Sec-3 Phase
...moreResidential Servo Stabilizer
Provides perfectly stable output even under severe conditions of unbalanced voltage conditions. Ideal to protect the electrical and electronic equipments from high and low voltage. Programmable Parameters Output voltage set ( 210-245V) Output Low Voltage Cutoff Input High on LCD Display Sensitivity / Regulation Over Load Cutoff CT full scale Output High Voltage Cutoff Input Low on LCD Display
...moreRated Transformers
K-Rated Isolation Transformer is to deliver conditioned power to a nonlinear high harmonic current load and operate at safe temperatures while minimizing the harmonic currents In a data centre, all the distributed power loads are connected through a non linear power source, due to which HARMONICS generation is unavoidable. These generated Harmonics are flow back and directly effects the main power source, which a UPS. The effect of harmonics de-rates the capacity of UPS. Hence 100% utilization of UPS capacity becomes wasted. The effect of harmonics also creates much heat in the transformers of UPS. To eliminate these direct effects on UPS, K-Factor Transformers are designed based on the harmonics present the load. The special design of K-Factor Transformer helps us to depend on much to eliminate or withstanding from theeffects of Harmonics. Double wound , High Isolation Double sized neutral Insulation class “H” Regulation is better than 3.5% Overload rating of 100% for 10 secs Core of CRGO and conductor of copper Natural / Forced Air Cooled As per IS:2026 standards Attenuation: 80 db/100 db CMRR Primary connect as DELTA, secondary connection as STAR Efficiency of the transformer is minimum 98%
...morePower Conditioner
Most Suitable for CNC Machines Telecommunication Equipments Bio Medical Equipments Large Computer Installations Printing Machinery Scientific Equipments Cell Phone Networks Garment Equipments Textile Machineries ... and many more.
...moreOltc Distribution Transformer
Tappings Switch Tappings from 5% to -5% in steps of 2.5% or 1.5% for HV variation or as per customer’s requirement On Load Tap Changer OLTC of 16 steps for HV variation from +5% to -15% in steps of 1.25% or as per Specific requirements. OLTC for remote Autoparallel operation can also be offered.
...moreLt Panels
Product Special Features SMS facility for Energy Reading & Low Power Factor Earth fault relay Phase Sequence indication Most suitable for Industrial, Residential Airport , Stadium L.V Switchboard As per IS Standards IP 52 / 54 / 55 protection Indoor / Outdoor Electrolytic Busbars Aluminium / Copper Customized Panels Single Front / Double Front / Dead Front DMC / SMC Insulators Capacity Expandable Complete Earthing of Doors & Frame Shipping sections as per demand
...moreLinear Automatic Voltage Stabilizer
Servo Voltage Stabilizers come in a wide range of models. The standard 3-phase models are suitable for balanced & unbalanced supply/loads. Most Suitable for Cement Plants Air Ports Rolling Plants Flour Mills Engineering Units Cell Phone Networks Rice Mills Pharmaceutical Units Cold Storage
Frequency : 47-53Hz
...moreIt panel board
We are engaged in offering a wide range of LT Panel Board which are used for the application as main breakers and for the protection of feeder and branch circuits and connected equipment.LT Panel Board helps in providing shot circuit protection for all circuits like cables, starters, motors. This product is procured from reliable sources of vendors who uses high grade of raw material and advanced technology to make it highly durable and high in performance.
...moreIsolation Transformer
Most Suitable for CNC Machines Telecommunication Equipments Bio Medical Equipments Large Computer Installations Printing Machinery Scientific Equipments Cell Phone Networks Garment Equipments Textile Machineries ... and many more.
Output Voltage :
...moreFurnace Transformers
Multiple Shielding Techniques employed to reduce the inter winding capacitance to below 0.005 picofarad and increases DC Isolation to over 1000 Megaohms. Technically any transformer that has no direct current path between its primary & secondary windings provides isolation from any kind of leakage in Current, Spikes/Surges produced in the system. Provision of electrostatic shield in between primary & secondary winding depends upon its construction, specification & performance characteristics. Isolation / Ultra Isolation Transformer are being used to protect Electronic & Sophisticated equipments, CNC Machines from the excessive line voltage transients, spikes / surges produced in the system. Electrostatic shielding helps in grounding these spikes & not allowing to pass on to the secondary side of the transformer. Furnace Transformer are built in delta / star connection with neutral as floating & electrostatic shielding is used to protect the furnace from any kind of Earth Fault Tripping.
...moreDistribution Transformer
Subjected to rigorous and strict quality controls at every stage of manufacturing, Designed to meet latest national international standards like BIS, IS, IEC, ANSI, BS, DIN, etc., Wide range of Transformers duly tested at Central Power Research Institute, Bangalore , Bhopal Quality assurance programme available Off-circuit tap changer to provide +5% to -5% in steps of 2.5% (or as specified by customer) On-load tap changer to provide +5% to -15% in steps of 1.25% (or as specified by customer) 3 Phase, 50 Hz in voltages of 11 KV, 22 KV and 33 KV Continuous duty Painting as per IS / IEC standards Vector group Dyn 11 Standard fittings as per IS: 2026 / IEC 76 / BIS 1180 HV side cable box/Bare Bushings LV side cable box / bus duct Design conforms to BIS 1180 & IS:2026, BS 171, IEC 76 and other relevant standards Latest manufacturing techniques to ensure cost effectiveness and reliability Designed for 25 years of trouble - free performance Very low power loss and low noise Optimum utilization of active materials for sleek design Withstands electrical impulses, thermal and dynamic stresses
...moreAutomatic Power Factor Control Panel
Most Suitable for Manufacturing Companies BPO Organizations Shopping Malls Steel Mills Spinning Mills Cement and Paper Mills Offices & Buildings Hotel & Restaurants Rice Mills Hospitals Cinema Halls / Multiplexes Payback period is 8 to 10 months Reduction in maximum demand Energy saving up to 5% Low power factor penalty can be avoided Extended life for Switch Gears, Capacitors and Cables Avoid manual disruptions Avoid high current consumption losses Reduction in Electricity Bill All major components are of standard make like Siemens, Epcos, L&T and Schneider Microprocessor based automatic controller with power factor display All components are carefully integrated for reliable performance and longer life Capacitor duty Contactors and MCB or MCCB, are used to switch ON capacitors to minimize switching surges Uses small correction steps to maintain accurate setting Auto / Manual Facility, Cooling Facility Very low watt losses In-built time delay for switching ON of a capacitor bank to avoid impulse signal operation. All capacitor feeders have Auto / Manual mode facility with fuse protection and isolation Power Factor Controllers are designed to operate, Automatically with Micro Processor Based Automatic Controller Use a specially designed electronic control circuit that improves power factor to meet requirements of load switching pattern Improvement of power factor up to optimum levels is guaranteed Product range: 20 KVAr to 1000 KVAr. We provide solutions for improving plant power factor by installing our APFC panel Heavy duty capacitors with detuned filters will be provided where high level non linear harmonies present upto 30%
...moreAuto Variable Transformers
air cooled servo stabilizers
Servo Stabilizers are used to protect any critical equipment, which are effected by the fluctuation in the input supply and those equipments do not operate when they are not used at the specified voltage. Our Servo Stabilizers by providing constant output with tolerance of ±1% makes equipments operate efficiently and hence improve their life. Also protect from being damaged due to high and low voltage fluctuations.
...moreUltra Isolation Transformer
Most suitable for cnc machines telecommunication equipments bio medical equipments large computer installations printing machinery scientific equipments cell phone networks garment equipments textile machineries .. And many more.
Operating Temperature : 0° C to 45° C
...moresmall power transformers
Subjected to rigorous and strict quality controls at every stage of manufacturing, Designed to meet latest national international standards like BIS, IS, IEC, ANSI, BS, DIN, etc., Wide range of Transformers duly tested at Central Power Research Institute, Bangalore , Bhopal Quality assurance programme available Most Suitable for All DISCOMS Substations Inverter duty Transformer for Solar & Wind Power Generation Application Off-circuit tap changer to provide +5% to -5%, +7.5% to - 7.5% , +10% to -10% taps On-load tap changer to provide +5% to -15% taps in steps of 1.25% / +5% to - 15% in steps of 2.5% 3 Phase, 50 Hz in voltages of 11 KV, 22 KV and 33 KV Continuous duty Painting as per IS / IEC standards Vector group Dyn 11 ( or ) as required Standard fittings as per IS: 2026 / IEC 76 HV side cable box/Bare Bushings LV side cable box / bus duct Design conforms to IS:2026, BS 171, IEC 76 and other relevant standards Latest manufacturing techniques to ensure cost effectiveness and reliability Designed for 25 years of trouble - free performance Very low power loss and low noise Optimum utilization of active materials for sleek design Withstands electrical impulses, thermal and dynamic stresses
...moreK-Rated Transformers
K-Rated Isolation Transformer is to deliver conditioned power to a nonlinear high harmonic current load and operate at safe temperatures while minimizing the harmonic currents In a data centre, all the distributed power loads are connected through a non linear power source, due to which HARMONICS generation is unavoidable. These generated Harmonics are flow back and directly effects the main power source, which a UPS. The effect of harmonics de-rates the capacity of UPS. Hence 100% utilization of UPS capacity becomes wasted. The effect of harmonics also creates much heat in the transformers of UPS. To eliminate these direct effects on UPS, K-Factor Transformers are designed based on the harmonics present the load. The special design of K-Factor Transformer helps us to depend on much to eliminate or withstanding from theeffects of Harmonics. Double wound , High Isolation Double sized neutral Insulation class “H” Regulation is better than 3.5% Overload rating of 100% for 10 secs Core of CRGO and conductor of copper Natural / Forced Air Cooled As per IS:2026 standards Attenuation: 80 db/100 db CMRR Primary connect as DELTA, secondary connection as STAR Efficiency of the transformer is minimum 98%
...moreBe first to Rate
Rate ThisOpening Hours