Weather Monitoring System
Applications The most powerful package for optimizing your irrigation and Integrated Pest Management (IPM) decisions. Description This powerful weather station measures, calculates and logs evapotranspiration (ET), solar radiation, wind speed/direction, wind chill, dew point, temperature, RH and rainfall.Complete, Self-contained, Digital Meteorological Monitoring System that provides instant access to weather information like Wind Sensor for Speed & Direction Temperature & Relative Humidity, Solar Radiation / Sunshine Duration Barometric Pressure Precipitation for Rainfall Evaporation. Data logger with 200day storage capacity & provision for password protection & Software with wind rose charts Full-featured weather stations measure temperature, humidity, rain, wind and solar radiation (varies by model) Customize your station with plug-in sensors to meet your needs Accurate, real-time weather information directly from your orchard or vineyard Monitor, record and analyze over a dozen important growing conditions Log your data in fail-safe, non-volatile memory Choose measurement intervals from 1 to 60 minutes (holds 183 days of data with a 30 minute interval) Multiple PCs can access the station without impacting a master data collection plan. Use the LCD Display to check current and daily high/low readings without a PC 12-month battery power with four AA lithium batteries. Four AA alkaline batteries included for 10-month life. Communicate via wireless, cellular, shuttle, or direct connect (see Communications options page) Requires SpecWare Pro software (see Software page)
...moreVOC Monitoring Systems
Total VOC Detector for Continuous Volatile Organic Compound MonitoringTVOC is a fixed continuous VOC detector for the detection and measurement of total volatile organic compounds (VOCs). Its photoionisation detection (PID) capabilities utilise advanced patented Fence Electrode technology, a 3 electrode format with increased resistance to humidity and contamination.A robust fixed VOC detector, TVOC has a selectable detection range of 0 – 10 ppm, 0 – 100 ppm or 0 – 1000 ppm and is ideal for use in manufacturing and process industries where VOCs are typically present.With a 4-20 mA analogue output, the TVOC VOC detector can be simply integrated into a DCS control system to provide warnings and enable control of high VOC levels in the working environment.ATEX approvals enable a 3 wire TVOC system to be used in Zone 2 hazardous areas, without safety barriers. ATEX and IECEx approvals allow TVOC to be used in Zone 1 hazardous areas, with safety barriers.The TVOC fixed VOC detector utilises a diffusive sample technique resulting in less contamination issues compared to pumped systems, reducing lamp cleaning and servicing requirements. Simple to install service and calibrate, TVOC requires no hot work permit and the PID sensor is accessible and changeable in a matter of seconds.The TVOC fixed VOC detector is also available for use with a pumped system for applications where sample conditioning is required.TVOC is part of a range of VOC detectors that includes the hand held PhoCheck Tiger, PhoCheck+ and FirstCheck+ instruments.Features Independently verified as best performing PID technology Patented Fence Electrode Technology for fast, accurate humidity resistant operation ATEX: Zone 2 hazardous areas without safety barriers (3 wire option) ATEX & IECEx: Zone 1 hazardous areas with safety barriers (4 wire option) 3 wire option allows direct replacement of an existing PID area monitor (Zone 2 ATEX) Selectable detection range of 0 – 10 ppm, 0 – 100 ppm or 0 – 1000 ppm Diffusive monitoring - no pump required Scaled 4-20 mA analogue output Includes a 10.6 eV lamp Easy access PID sensor allows simple servicing Simple calibration procedure Applications The TVOC VOC Detector can be used to detect gases across a wide range of industries and applications, including: Pharmaceutical industry Chemical industry Indoor air quality Refineries and petrochemical plants Solvent recovery system Waste water treatment plants Offshore Pulp and paper industry Industrial painting and coating
...moreTURBIDITY METER
Applications To estimate the turbidity of a solution, for example: • Estimating the suspended matter in a water sample• Estimating the clarity performance in a centrifuge Description Industry-leading precision, sensitivity, and dependability in one of the most innovative handheld turbidity meters available on the market! NOW WATERPROOF!The multi-detector optical configuration assures long term stability and minimizes stray light and color interferences. All turbidity readings are determined by the process of signal averaging over a 5 second period. This minimizes fluctuations in readings attributed to large particles and results in rapid, highly repeatable measurements. Ideally suited for both low-level drinking water applications as well as monitoring high turbidity in the field. Features Waterproof to IP67 Lithium ion rechargeable battery USB port 7 languages Backlit display Meets EPA and ISO versions Logs memory up to 500 points. Stored results can be viewed directly or downloaded to a computer via USB Cable and SmartLink3 Software
...moreTUBULAR CENTRIFUGES
Applications • Purification of Fuel Oils for emergency power generators• Purification of Lubricating Oils • Purification of Rollin Oil, Quenching Oil and Hydraulic Oil• Purification of Waste Oil • Removal of foreign matters from lost-wax • Clarification of lacquer and solvent type paint. • "Solid-Liquid" separation of resin and slurry containing organic solvents• Recovery of catalyses• Pressurized "Solid-liquid" separation of heavy oil and waste plastics at high temperature. • TRV Decanters play a majot role in the PET plants. Description Many TSM Decanters are employed in he sludge volume reducing process of the wastewater treatment plants. They are also installed in feces, garbage and cattle-stall effluent treatment plants. TSM stands for the Triple-Saving Machine. It reduces maintenance labor, power consumption and flocculant consumption. Features Compactly built machine Low Noise: The optional cover reduces it further down to 80dB or less Easy and Quick Installation: limited number of anchor bolts Little Power Consumption: 20-40% less than the conventional ones Wear resistive tile chips on the screw conveyor flight: less spare parts and less repair expenses Both the TSM dewaterer and thickener accomplish high solid recovery. As the liquid collecting cover and the discharge port are separated, this unit can be disassembled without disconnecting the liquid piping's from the unit.
...moreTOTAL ORGANIC CARBON (TOC) ANALYZER
Applications • Measurement of TOC in purified water as per USP/EP and water for injectibles as per USP/EP/IP/JP• Water purification plant validation • Validation of water distribution system• Measurement of TOC in Raw water / Feed water Cleaning Validation Description The TOC-L series of TOC analyzers adopts the 680°C combustion catalytic oxidation method, which was developed by Shimadzu and is now used worldwide. While providing an ultra wide range of 4 μg/L to 30,000 mg/L, these analyzers boast a detection limit of 4 μg/L through coordination with NDIR. This is the highest level of detection sensitivity available with the combustion catalytic oxidation method. In addition, the combustion catalytic oxidation method makes it possible to efficiently oxidize not only easily-decomposed, low-molecular-weight organic compounds, but also hard-to-decompose insoluble and macromolecular organic compounds.FeaturesExtremely wide measurement range from 4 μg/L to 30,000 mg/L, applicable to everything from ultrapure water to highly contaminated water (TOC-LCSH/CPH) Capable of TC, IC, TOC (= TC-IC), and NPOC measurement; options enable POC (volatile organic carbon), TOC via POC + NPOC, and even TN (total nitrogen) measurements The blank check function evaluates system blanks by measuring ultrapure water processed automatically within the instrument The automatic dilution function enables measurements up to 30,000 mg/L Reliable sample injection system Automatic sample acidification and sparging The automatic dilution function reduces sample salinity, acidity, and alkalinity, significantly extending the period of use of catalysts and combustion tubes (The period of use depends on the sample and measurement conditions.) Stat or priority samples can be added at anytime to the analysis schedule without interrupting operation even when an autosampler is used Select from 4 models to suit your application The TOC-L series consists of a high-sensitivity model with a detection limit of 4 μg/L, making it suitable for a variety of applications, including pure water measurements, and a standard model designed with cost performance in mind. Each analyzer is available as an LCD and keyboard-equipped standalone model, or as a PC-controlled model. In addition, the USB format has been adopted as the external interface, enhancing the equipment’s versatility. Even the standalone models are capable of output to a general-purpose PC printer or to a USB memory stick. Options to further enhance functionality With the TOC-L series, numerous options enable a variety of functional enhancements. These include simultaneous measurement of TOC and TN (total nitrogen) (when a TN unit is added), the use of compressor air (when a carrier gas purification kit is added), and the measurement of gas samples and solid samples (when a gas sample injection kit and solid sample combustion unit are added). Sea water sample measurement and small sample volume options have also been enhanced. Space-saving and energy-saving design The width of the instrument is 20 % less in comparison with conventional Shimadzu models. This enables more effective use of laboratory space. The instrument width is unchanged even when the TN unit is added. This product conforms with Shimadzu’s ECO labeled product. Energy Saving: Power consumption reduced by 36 % (100 V) and 43 % (200 V) as compared to a conventional Shimadzu product. (Assuming 8 hours operation/day × 5 days/week)
...moreSterility Test Isolator
Applications Sterility Test Hospital Pharmacy Life Sciences research Clinical trails Description Modular aseptic processing solution in convenient configurations to meet your workflow Air cleanliness ISO 5 and Grade A working environment with integrated Bioquell HPV 6-log bio-decontamination for peace of mind Fast cycles and quick turnaround between tests - get more from your day. The Bioquell QUBE is a modular aseptic working system consisting of a series of major components : QUBE HPV Module (QHPV) (M1) QUBE Extension Module (QEXT) (M9) QUBE Connecting Interface Modules (Open Connection or Sealed Door) (M11) QUBE Material Transfer Device (QMTD - Right or Left Side) (M2 or M3) Undertake aseptic processing in a Bioquell QUBE, a cost-effective modular aseptic workstation system with built- in rapid bio-decontamination. The combination of uni-directional airflow, an ISO 5 and Grade A working environment and hydrogen peroxide vapour (HPV) rapid bio-decontamination ensures the Bioquell QUBE is suitable for applications such as pharmacy compounding, sterility testing, and many others. Performance is assured by using Bioquell approved hydrogen peroxide solution. The Bioquell QUBE modules allow a variety of configurations that tailor the workspace to the needs of the specific process. Fully validated sterility test unit with built-in biodecontamination system Ergonomically designed using latest manufacturing techniques,Rapid sporocidal bio-decontamination process with high level validated 6-log sporocidal reduction Intelligent modular design provides users flexibility in selecting the suitable configuration for their process Air cleanliness ISO5 and grade A working environment with integrated bioquell HPV 6-log biodecontamination Integrated environmental monitoring for total viable and non-viable practical monitoring. Bioquell QUBE with extension module and materials transfer device, ideal for phamaceutical compounding. Key features A modern ISO 5 Grade A chamber with uni-directional air flow that includes a high definition colour touch panel with intuitive icon driven interface, glove ports with safe change gloves, RFID enabled hydrogen peroxide filling and pneumatic seals with pressure monitoring for repeatable chamber integrity. Chamber pressure can be controlled from +100pa to -100 pa and there is a built-in aeration capability with every module for fast decontamination cycles. The system has been engineered to keep noise levels low and a 316 Grade stainless steel level floor has been provided throughout the system along with an integral thermal paper printer to keep a record of the bio-decontamination cycle and key GMP parameters. Ergonomically designed, the Bioquell QUBE provides an integrated footrest and foot switches for door activation.It uses novel plastics technology to enable excellent ‘cleanability’.
...moreSound Level Meters
Applications To measure noise levels during industrial activity construction activity workplace activity fire crackers usage music systems usage generator sets usage loud speakers /public address systems usage vehicular horns usage and other mechanical device' usage Description Designed for measurement of work place noise levelsSD 200Sound Detector SD-200 is a compact, lightweight sound level meter designed to accurately measure workplace noise levels. Green, yellow and red LEDs flash the color that corresponds to the Optime Alert System, making it easy to select the appropriate level of hearing protection. The SD-200 offers an integrating feature that computes the average sound pressure level, allowing for more accurate assessment of intermittentsound levels. The user-friendly interface makes the SD-200 easy to operate. A rechargeable lithium polymer battery helps lower the total cost of ownership compared to other sound level meters that use replaceable batteries. AdvantagesIn many work environments, noise levels are highly variable, making it difficult to accurately measure sound levels. The SD-200 helps solve this problem by providing the average sound pressure level. This advanced functionality is easy to use and delivers a steadier reading in environments such as manufacturing facilities or machine shops where noise levels are often highly variableFeatures Integrated Sound Level Meter which gives Leq or Lavg Rechargeable Lithium polymer (1000mAh) battery which gives runtime more than 50 hours with low battery Indication. USB cable provided to charge the instrument with the computer. The user selectable LED Alert screen provides a quick visual reference of sound levels with green, yellow and/or red LEDs that flash when preset noise levels have been reached. Meets ANSI S1.41983(R 2006), ANSI S1.43 1997 (R 2007), IEC 61672-1 (2002) IEC61010-1 (2010), EC standards. Displays all required measurements like Sound Pressure Level (SPL), Average value (LEQ /LAVG), LED Alert (with Hearing Protection icon), Maximum value (MAX), Minimum value (MIN), Run-Time, Overload (OL), and Under-Range (UR).
...moreSONIC WEATHER STATION
This AIO 2 integrates a unique low-power sonic anemometer, the Sonimometer™, with a multi-element temperature sensor, fast-response capacitive relative humidity sensor, state-of-the-art barometric pressure sensor, and an internal flux-gate compass for automatic alignment of wind direction to magnetic north for quick deployment (true/magnetic North offset is adjustable by the user through software command). The result is a professional grade, next-generation, compact all-in-one weather station designed for reliability, longevity, and ease of installation which can measure temperature, relative humidity, wind speed, wind direction and barometric pressure. Robustness: The small footprint and power efficiency of the AIO 2 make it ideal for remote regions, urban environments, air quality networks, construction/remediation sites, and other network applications. Portability: Designed for maximum portability and utility, the AIO 2 is uniquely applicable for rapid deployment and use by one person under all conditions. The unit may be mounted on a tripod or vehicle mast. Data logging: Data output is a serial, digital message that can be interfaced to most data logging systems. Software is provided for user interface. Options are offered for wireless communication. Accessories: Carrying cases, compact quick deploy lightweight tripod and external power options. Features: • All-In-One Measurement of Temperature, Relative Humidity, Wind Speed, Wind Direction & Baro-metric Pressure • Integrated Sonimometer™ Wind Sensor • Automatic Wind Direction Alignment to Magnetic or True North • Rugged, Reliable, Quick to Deploy • All Metal Construction • Weather Protected Multi-Sensor Design • No Moving Parts • Low Power Consumption • Digital Output • Proven Field-Use History Applications The most powerful package for optimizing your irrigation and Integrated Pest Management (IPM) decisions.
...moreRespirable Dust Sampler
The Sidekick sampling pump - a favorite with SKC customers. Reliability and simplicity make it a good entry level pump, whilst high build quality, means it won’t let you down. All models offer a wide flow range of 5-3000 mlmin, which means the Sidekick is suitable for dust and gas sampling projects. The lower flows are achieved with the constant pressure controller and low flow adaptor.
...moreRAPID & NON - DESTRUCTIVE GROWTH DIRECT SYSTEM
Applications Environmental Monitoring Sterility Testing Bioburden Testing Description The Growth Direct™ System consists of an automated imaging instrument that analyzes user-prepared proprietary consumables called Growth Cassettes™. The system and consumables were designed to optimize test performance and ease-of-use. In addition to rapid enumeration of microbes compared to the culture method, a major attribute of theGrowth Direct™ System is the automated handling and analysis capability that reduces hands-on time required by technical staff. The growth direct system is the first and only automated system that addresses all key microbial QC applications like sterility, environmental monitoring water and bioburden Rapid micro biosystem's growth direct test uses digital imaging technology that automatically enumerates micro colonies days earlier than the traditional plate methods The system captures the fluroscence (autofluroscence) that is emitted by all living cells A positive result will be available within hours and a final result in about half the time of the compendial test The system monitors tthe internal opeations of incubators including tempearatutre humidity and capacity Growth direct automatic detection methods can minimize manual errors and ultimately reduce expenses For sterility testing the system ensures the oxygen free status of the anaerobic sample Different incubation temperatures can be programmed in single unit
...moreRAPID BIO-MASS DETECTION SYSTEM
Applications Measurement of Adenosine Triphosphate (ATP) to obtain a complete microbial quantitative measurement. True and rapid measurement of total living organisms First line of defense for microbiological thretats control in all type of fluids like potable / raw water / purified water measurement Prominent tool to identify the source of bio burden in purified water Validation of water distribution points Second generation ATP allows to be appiled to essential any application where microbial growth is of concern Real time microbial monitoring leads to more productivity/profitability Description Luminultra 2ndgeneration ATP test kits developed for rapid determination of microbial population of almost all fluid samples from drinking water to industrial process water, chemical products and waste water.ATP Bioluminescence assay is the best solution to overcome the traditional method problems. Because of its speed and specificity to biological activity, ATP measurement can play a key role in defending against failing drinking water quality, including those encountered during routine operation. Advantages It is fast – results are available in a matter of minutes rather than days It is complete – since ATP is present in all cells, it provides a direct indication of the total microbial population. It is portable – the test can be performed reliably in the field, thereby eliminating sample transportation and processing times, providing on-the-spot results for real-time troubleshooting. Immediate investigation to solve the incursions to save time costs and reduce risk To release the production immediate without wait for seven days culture test result It is the first line of defense in identifying threats, after which follow-up testing to identify problematic species can be undertaken. This is a tremendous advantage which allows operators to take immediate action to solve microbiological build-ups or incursions to save time, costs and reduce risks and you need not to wait for traditional seven days results to release the batch of bottles after getting fast and immediate results from ATP method. Features First line of defense for microbiological threats control in all type fluids like drinking water/waste water,Upstream oil and gas,metal working fluids,chemicals,personal care products. Measurement of Adenosine Triphosphate (ATP), obtain a complete and fully-quantitative measure of total microbial content in less than 5 minutes. It measures true total bioburden Second generation ATp allows to be applied to essential any application where microbial growth is of concern. Luminultra technology is rapid,accurate,complete,quantitative and reliable Real time feedback increases productivity and profitability
...morePORTABLE REAL TIME AEROSOL MONITOR
Applications Controlled Environments Indoor Air Quality Hospitals & Clinics Process Control HVAC Applications Filter Testing Mining & Ore Processing Emission Sourcing Industrial Hygiene Occupational Hygiene Point source location monitoring Indoor Air Quality Remote Sampling FeaturesParticle Mass Profiler and Counter in a Single Handheld Unit The Aerocet 531S is a small, handheld, battery operated, and completely portable unit. This unit provides particle counts or mass PM measurements as stored datalogged values, real-time networked data, or printed results. Six Mass Ranges and Four Particle Sizes Six important mass size ranges (PM1, PM2.5, PM4, PM7, PM10, and TSP) are displayed in mass mode as well as four popular cumulative particle sizes (> 0.5, 1.0, 5.0 and 10.0 microns) in count mode. Tailored Mass Conversion The particle counts from eight size ranges are converted to mass using a proprietary algorithm for typical-density aerosols. Accommodation for special particulate with different densities is provided through user–programmable "K-factors." Flexible Data Interfaces The Aerocet 531S stores up to 6,257 records. These records can be viewed on the display, or transferred to a computer via USB or RS232. Our included Comet download utility makes file transfers easy. Data files can easily be imported into an Excel® formatted output. Temperature and Relative Humidity Option A plug-and-play option that immediately adds ambient temperature and relative humidity capabilities to the displayed and logged data.
...morePORTABLE & PERSONAL VOC MONITOR
Applications Environmental monitoring Indoor air quality measuring industrial volatiles Health & safety, STEL & TWA monitoring in confined space General leakage in fuel and chemical storage Filter monitoring in clean rooms and air conditioning Leak detection Gas line leakage in laboratories Environmental clean up after spillage Illegal dumping of chemicals Medical gases within hospitals Fence line monitoring for plume detection Soil contamination detection
...morePORTABLE FTIR GAS ANALYSER
Applications • Stack testing according to USEPA methods 320 and 321 or European standards• Process monitoring• Formaldehyde emissions monitoring from biogas plants: VDI 3862 Blatt 8:2014-01• Stack testing according to British Technical Guidance note M22: Measuring stack gas emissions using FTIR instruments, Environment Agency, Version 3, March 2012• Reduction of greenhouse gas emissions by cattle -research Description Gasmet™ DX4000 is a portable FTIR gas analyzer which is typically used in stack emissions monitoring, comparison measurements, catalytic process control and other applications where multiple gas compounds need to be accurately monitored in hot & humid sample gas. The corrosion resistant sample cell is heated to 180 °C, which ensures that the sample stays in gaseous phase even with high concentrations of H2O or corrosive gases.Gasmet™ DX4000 comes equipped with easy-to-use Calcmet™ software, which can display the concentration results in ppm, mg/Nm3 or Vol-%. All measurement data can be stored for further analysis.Gasmet™ DX4000 is typically set-up to measure H2O, CO2, CO, NO, NO2, N2O, SO2, NH3, CH4, HCl, HF and different VOC´s. Additional gases can be added without any hardware changes. Measurement ranges can be selected from sub-ppm until vol-% level.Gasmet™ DX4000 can be supplied with the Gasmet™ portable sampling system. This system utilizes hot-and-wet measurement principle (no drying or dilution), which ensures that the analysis is done with a representative sample. There are two stage particulate filtration: first one in sampling probe (2 µm) and second one in sampling system (0.1 µm).The portable sampling unit can be optionally equipped with a ZrO2 sensor for accurate oxygen measurement.Gasmet™ DX4000 has received the coveted MCERTS certification for stack emissions monitoring. There is also VDI 3862 standard for measuring formaldehyde emissions from biogas plants in Germany.Key Advantages: Easily configurable application for new gas components Post-measurement data processing tools are unique to Gasmet Wide range of applications
...morePortable Dust Sampler
Ambient Fine Dust Sampler is designed to measure Ambient Air Pollutants for PM10 PM2.5 according to the CPCB guidelines. Choice of sampling inlets for PM10 , PM2.5 & TSP Data Storage for Ambient Temperature, Filter Temperature, Barometric Pressure, Real time Flow and Volumetric Flow Rate A Unique feature in-filed data retrieval by USB interface for remote locations Unique feature of Thermal Electrical Gas Sampling attachment.
...morePORTABLE AEROSOL MOBILITY SPECTROMETER
Applications Personal Nanoparticle/Aerosol Exposure Measurement Workplace protection factor measurement of respirators Atmospheric process studies Air pollution and air quality measurements Combustion and engine exhaust emission measurements Filtration studies Inhalation toxicology studies Indoor air quality studies Description PAMS is an electrical mobility size spectrometer designed for portable, mobile, or handheld aerosol sampling applications. It provides the number-weighted diameter distribution of aerosols over the entire submicrometer range (10 to 863nm) in one scan. The unit uses a nonradioactive bipolar aerosol charger to allow easy access to sampling sites with tight safety regulations. Its bipolar charger significantly reduces measurement uncertainty of larger particles in the submicrometer range. Features: Electrical mobility size spectrometer designed for portable, mobile, or handheld aerosol sampling applications Provides number-weighted diameter distribution of aerosols over the entire submicrometer range (10 to 863nm) in one scan Uses a non-radioactive bipolar aerosol charger to allow easy access to sampling sites with tight safety regulations Bipolar charger significantly reduces measurement uncertainty of larger particles in the submicrometer range Can be used in two modes: Single diameter count mode: to get a total count within a narrow size range or Size distribution mode: to get an automated size distribution measurement over desired size range or size resolution Stand-alone, battery-operated instrument; no external computer needed. Weighs only 4.5 kg and measures 23 x 23 x 15 cm.
...morePIEZOBALANCE DUST MONITOR
Applications IAQ Investigations Industrial Hygiene Occupational Health & Safety Product Quality Control Laboratory Research Description While conventional dust meters "count" particulates, the Piezobalance dust meter "weighs" mass concentration of particulates. The Data can be reviewed on-screen, printed or downloaded to a computer. Software is included for easy data download and processing. Has a simple cleaning mechanism for easy maintenance. Features: Data logging ability allows user to log 500 samples Simple cleaning mechanism for easy maintenance RS232C port available as standard Back-lit display
...moreparticle counters
Applications Cleanroom verification Clean Bench verification Filter Testing Facility Certification Food Process Investigation Hospital Surgical Room Description Handheld 2.83 LPM (Model 3886) Portable Monitor 50LPM (Model 3910) / 28,3 LPM (Model 3900) Continues Monitor 2.83 LPM (Model 3714/3715) Smallest and lightest portable particle counter in the industry (Model 3910) Simultaneous measuremnt and display of 6 particle sizes 0.3 micron sensitivity 21 CFR part 11 compliant Measures multi - parameters, air velocity, relative humidity, temperature, pressure Meets ISO 14644-1, Federal standard 209 E, British Standard 5295 and EU-GMP Measures multi -parameters, particle air velocity temperature, humidty, differential pressure Multi-function, user -friendly monitoring software 1PC system controls upto 128 sensors Benefits Featherlight with an ultra-small footprint Large Color Touch Screen Multi-parameter: Particle, Airflow, Temperature, Humidity, Differential Pressure Mulit-standard mode: ISO 14644, FS 209E, BS 5295, EU GMP
...moreONLINE BENZENE SPECIFIC MONITOR
Applications Detection of ambient benzene in below industries:• Oil&gas• Petrochemical • Chemical • Health&safety Description Launching world’s first continuous benzene specific monitor !The revolutionary ‘Titan’ has been specially designed for the accurate and reliable detection of ambient benzene in petrochemical applications where traditional methods suffer cross interference – providing the ultimate real-time protection of workforce, environment and plant.Traditional photoionisation detection (PID) monitors easily detect benzene but they also identify other less harmful volatile organic compound (VOC) gases that are normally present at the same time. Offering rapid and accurate detection, ‘Titan’ continuously samples and analyses the environment to provide real-time feedback of ambient benzene levels. When a sample is taken, the benzene component is chemically filtered using a robust separation technology so ensuring no false-positives are measured with potential cross-contaminating compounds in the atmosphere. Incorporating the well proven Ion Science MiniPID technology at the heart of the instrument, ‘Titan’ is highly sensitive and capable of detecting benzene levels down to 0.1ppm and up to 20ppm.‘Titan’ features a clear display and provides users with an immediate warning alarm system when hazardous levels of benzene are detected ensuring the on-going safety and protection of workers. The instrument provides two relays with configurable levels to integrate into site alarm systems. Flashing lights are used as an alarm signal to give a clear indication when benzene levels present.‘Titan’ stores data internally and remotely connects to a PC. Its continuous, real-time measurement facilitates the analysis of trends and allows activity levels to be accurately identified.Designed to operate in conditions ranging from -20 ºC up to +60 ºC , ‘Titan’ is unaffected by changes in ambient temperature. It incorporates two temperature regulation systems to ensure critical components perform optimally.Modular in design, ‘Titan’ is easy to service and designed to operate for as long as possible without intervention. Working parts can be easily removed and serviced, or replaced by another ‘plug and play’ service module. It also provides removal of particulate contamination in the air stream to provide long-term service free sampling.‘Titan’ utilises the company’s unique patented Fence Electrode technology for unrivalled resistance to humidity and contamination. This key feature makes ‘Titan’ ideal for extended operation in harsh environments.‘Titan’ is designed to IP65 and meets ATEX / IECEx hazardous area safety approvals.Features: The first truly specific benzene monitor No cross sensitivity to other VOC gases No consumables required (e.g., detector tubes, carrier gas) Detects benzene to sub ppm levels Fast, accurate, reliable detection Continuous, minute by minute sampling Real-time warning alarm system to the hazards of benzene Operates in extreme temperatures Designed for easy installation and servicing 6 months maintenance free operation Increases safety, reduces costs Provides the ultimate protection for plant, workforce and environment
...moreOdor Monitoring Systems
The RQ Box solution provides site operators a real dashboard of odor emissions and gaseous pollutants: the level of emissions and the impact of their dispersion around the site are available directly from the monitoring center located on siteFeatures: Continuous measurement of emissions, to the nearest second Odor concentration (odor unit), in accordance with current standards : EN 13725, ASTM E679 Concentrations of gas pollutants (ppm) : VOCs, NH3, H2S or mercaptans Dispersion modeling of emissions around the site Dynamic visualization of the « odor » or « pollutant » plume on a 3D/4D map Dispersion modeling per source or for the whole site Calculation of concentration at geo-localized points of interest around the site Assessment of the contribution of each source in terms of emission Automated daily dispersion reports Onsite monitoring, away from emission sources Management of real-time alerts in the event the threshold is crossed Triggering of warning systems: siren (two tone), flashing lights, sms, etc. Automatic calculation of the frequence of threshold exceedance Control of odor treatment facilities Advantages: Operator alerted in real time in the event the threshold is crossed Odor treatment processes optimized thanks to integrated facility control Return on investment between 9 and 18 months with treatment facility control, due to economies of water, process chemicals and energy A reliable tool for decision support to reduce pollution and be part of a process of continuous improvement: ISO 14001, ISO 9001 An « odor » issue simplified thanks to a continuous instrumental measurement Emission levels reduced by better knowledge and control of operating conditions Historical results, easy to interpret, which facilitates communication between operators, local authorities and residents A flexible and scalable solution : Sampling system suitable for all types of sources: channeled, surface, volume A modular measuring device according to the site: analyzers, weather station, dispersion Integration of the most powerful dispersion models (3D Lagrangian calculation engine) or simplified systems (2D Gaussian) Applications The RQ Box solution provides site operators a real dashboard of odor emissions and gaseous pollutants: the level of emissions and the impact of their dispersion around the site are available directly from the monitoring center located on site.
...moreOdor Meter
Applications Hospitals & Nursing Homes IAQ investigation (VOCs) Effluent Treatment Facilities Description Handheld odor meter model OMX, is the most simplified tool for odor analysis, which enables to indicate the relative strength and odor classification numerically by comparing odor gas and purified air. The reading shown on display is calculated based on our original principle Finding odor source at factories, incinerator plant, or ETP facilities Evaluation of deodorizing at hospitals or nursing homes etc. Features Numerical value for relative strength of smell Numerical value for classification of smell Handheld Odor meter is ideal for Before and After applications, such as air purification and cleaning service. Real-time sampling mode displays odor change continuously Memory sampling mode saves data based on the selected sampling rate. (up to 32732 data, 511 files) Battery operated with 7 hrs continuous usage
...moreNOISE MONITORING SYSTEM
Applications To measure the ambient environmental noise. Description Noise Monitoring System is a fully integrated solution for unattended noise monitoring applications featuring an internal web server for system configuration, live data streaming, data management and battery powered operation providing true flexibility for both short and long term measurements The measurement capabilities are optimized for noise monitoring applications . It measures and stores results suitable for automatic automatic reports, detailed information for advanced post-processing analysis and streams live data stream for real time noise monitoring. SV 200SV 200 Noise Monitoring Station is a fully integrated solution for unattended noise monitoring applications featuring an internal web server for system configuration, live data streaming, data management and battery powered operation providing true flexibility for both short and long term measurements.The measurement capabilities of the SV200 are optimized for noise monitoring applications. It measures and stores results suitable for automatic reports,detailed information for advanced post-processing analysis and streams live data stream for real time noise monitoring. Standard measurement functionality includes multi-profile data logging, real time 1/1 and 1/3-octave logging, audio event recording and statistical analysis. Measuring capabilities can be extended with real time audio streaming and weather condition monitoring. SV 200 can be used for both and 0° and 90° reference direction, typically used for aircraft and environmental noise. The reference direction is user selectable in the instrument configuration.The weatherproof housing protects SV 200 noise monitoring station against extreme weather conditions while fulfilling class 1 accuracy. Special attention was given to the highly efficient windscreen which reduces noise, even at high wind speeds. Internal heating and rugged a dual layer housing enables the SV 200 to operate from -30°C up to +60°C and humidity up to 100% RH.SV 200 has a 2,45 Ah internal Li-Ion battery and interface for connecting solar panels. A waterproof mains adapter for charging the battery and powering the station is also included. The system is specially designed for easy installation - SV 200 is small, light weight and easy to install by a single person.The SV 200 is available with an integrated low power 3G modem or Wi-Fi access point. The implementation of advanced and highly reliable communication protocol gives the user full control of the station, offers easy to use data transmission, real time data publication and live audio streaming. Station configuration and data management is done by using a web browser or the SvanPC++ RC server application.Features ‘All in one’ design for portable, mobile and permanent noise monitoring installations Real-time 1/1 or 1/3 octave analysis Audio events recording Rugged housing protecting the system against harsh environmental conditions (IP66) Integrated electrostatic actuator for full system verification Class 1 according to IEC 61672 Integrated high speed 3G or Wi-Fi modem Automatic time synchronization Large windscreen against high-speed wind Intelligent heater protecting microphone against humidity Live audio & data streaming capabilities Low power consumption, integrated Li-Ion battery and direct connection for solar panels Highly reliable and secure data push and configuration pull communication protocol Both, server and web based system configuration Community & airport characteristics available simultaneously
...moreMicrobial Identification System
All Biolog Microbial Identification Systems viz., Manual, Semi-automated or Fully-automated use the powerful new GEN III MicroPlate, thus allowing users to choose the most appropriate system that fits their current budget and level of throughput without any compromise in technology. For the pharmaceutical microbiologist an array of different identification systems are available. But most of the systems available have databases orientated towards clinical microbiology and thus such databases may not be representative in terms of the types of microorganisms found within pharmaceutical grade clean-rooms.
...moremicrobial air sampler
Applications Clean Room Isolator Agro, Food, Dairy, Beverage Production sites Microbiological Laboratory Biotechnology Premises Vaccine Production Plant Waste Water Treatment Plant School, University training and teaching Hospital & Clinics Indoor Air Quality Public Health Authorities Description DUO SAS SUPER 360: When the environment contamination is very low and the number of samples to be performed is high, the duration of the operations can be an important factor in the choice of SAS instrument. With two sampling heads that can operate simultaneously, DUO SAS 360 is the correct solution to sample 1000 L of air in less than 3 minutes.Features Single body with two aspirating heads: two separate plates may be used for simultaneous sampling to differentiate microorganisms (onto two different media) or onto the same media To calculate an average value and to obtain a more representative result
...moreBe first to Rate