Ultrasonic Flaw Detector Modsonic Einstein II DGS.
220,000 - 250,000 Per Piece
10mmto 5 meter (0.500 in to 200 in) (in steel). In Hot Key mode it has 13 preset values. Fine mode adjustable in step of 1mm(0.2 in). Pulse echo and transmit/receive. BNCandLEMO(Size 1) both are provided. Dual gate adjustable in1%of Screen width with Positive/Negative logic, Gate Expand modes. Lithium-Ion Battery pack 14.4VDC,4AH, gives 8 hours continuous operation from fully charged battery. Input Voltage 100 to 240 VAC. Charge status indicator is provided. 0 to 55 C. (For operation) 152 x 255 x 70mm (HxWxD). 2.3 Kgs. with Battery. 1000 m/sec to 9999 m/sec (0.0400 in/μs to 0.4000 in/μs). In Hot Key mode it has 7 preset values. Fine mode adjustable in step of 1 met/sec (0.0001 in/μs). Variable from 0 to 3000mm (0 to100 in). In Hot Key mode5mm(0.2 in). Fine mode adjustable in step of 0.5mm (0.02 in). A- Scan Freeze and Peak Freeze available. In Peak freeze it holds echo dynamic pattern which is useful during angle beam probing to locate peak signal. 100 dB calibrated gain adjustable in 0.5, 1, 2, 6, 12 or 20 dB step. 0 to 100% FSH with LED indicator. Full-wave rectified with filtering. Broad Band amplifier 0.5MHz to 15 MHz. Transmission pulse Negative spike with selectable high or low power. Damping high / low is selectable. Expands Range to width of the gate. 200Trace Patterns can be stored , recalled, printed or transferred toPCvia RS-232 serial port. 50 different calibration set-ups can be Stored and Recalled. EinSoftDGSInterface software for transferringA-Scan from Einstein- toPCis supplied. IBM compatible Printer having serial port can be directly attached to main unit for printing of stored A-Scan waveform with calibration data. High brightness Colour LCD/TFT Display . Display area 320x240 pixel(122x92mm). Eleven different color scheme option. By pressing Zoom keyA-Scan can be displayed in Full Screen area. Reference A-Scan pattern of standard test object can saved and recalled in the background for easy comparision during testing. Dynamic DAC curve can be Digitally plotted on screen with -6dB and -14dB DAC curves. DAC curve can be set as flaw monitor gate. Using minimum 2 to maximum 10 pointsDACcurve can be plotted. Defect size evaluation can be performed using 18 predefined probe settings and custom probe set-ups.Defect size is directly displayed inERSvalue (Equivalent Reflector Size). Thickness/Depth can be displayed in digital readout when using a normal probe and Sound path, Surface Distance and Depth are directly displayed when angle probe is in use. 50Hz.
Ultrasonic Leakage Detector
Get Price Quote
Best Deals from Ultrasonic Detector
Steam Trap Valves Inspection Kit
12,000 Per
Ultrasonic Crack Detector
1,610,000 Per Piece
Ultrasonic Flaw Detector
Get Price Quote
Ultrasonic Flaw Detector, compacting factor apparatus