Electric Control Panels Dealers in Manikbag, Indore (6 products available)

  • auto transformer starters

    auto transformer starters

    1,500 - 1,550 Per HP

    1 Piece(s) (MOQ)

    • Type: Auto Transformer Starters
    • Max Current: Other
    • max voltage: 380V, Other
    • Feature: Accuracy,Adjustable,Durable,High Quality,Long Working Life,Optimum Efficiency,Precisely Designed,Simple Usage

    Motor is connected in delta from the start. Auto transformer provides voltage to the motor at start. Appropriate lower voltage tapping –customized as per the application – is provided to the motor. After the motor has attained significant torque changeover from auto transformer to on line takes place. The changeover is “closed transition” i.e. During changeover the auto transformer acts as a choke supplying voltage to motor – hence smooth or stepless or soft starting takes place. The motor then runs on line current. The transformer is isolated from both the ends to protect the contactors. Adjustable high torque: a high torque (up to 64%) possible and can be customized by voltage tapings. No power quality issues: all standards electrical components ensure that there are no harmonics or other power quality issues. Transient elimination: korndorfer closed transition technology ensures that transients are eliminated. Motor protection: motor is connected in delta at the time of starting to avoid high inrush current in the motor winding thus providing lesser heat generation. Reduced voltage starter: voltage controlled by auto transformer at the time of starting. The capicity of ats is 15hp to 1000 hp rs. 1111/- per hp for any starter.

    more..
  • Fire Alarm Control Panel

    Fire Alarm Control Panel

    Get Price Quote

    • Type: Automatic
    • Color: Red
    • Voltage: 220V
    • Body Material: Mild Steel
    • Power Source: Electric
    • Phase: Single Phase
    • Warrenty: 1 Year
    more..
  • Best Deals from Electric Control Panels

  • Auto Transformer Starters Controller Panel

    Auto Transformer Starters Controller Panel

    Get Price Quote

    We are offering auto transformer starters controller panel. Motor is connected in delta from the start. Auto transformer provides voltage to the motor at start. Appropriate lower voltage tapping- customized as per the application- is provided to the motor. After the motor has attained significant torque changeover from auto transformer to on line takes place. The changeover is “closed transition” i.e. During changeover the auto transformer acts a choke supplying voltage to motor- hence smooth or stepless or soft starting takes palace. The motor then runs on line current. The transformer is isolated from both the ends to protect the contactors. Adjustable high torque: a high torque (up to 64%) possible and can be customized by voltage taping. No power quality issues: all standards electrical components ensure that there are no harmonics or other power quality issues. Transient elimination: korndorfer closed transition technology ensures that transients are eliminated. Motor protection: motor is connected in delta at the time of starting to avoid high inrush current in the motor winding thus providing lesser heat generation. Reduced voltage starter: voltage controlled by auto transformer at the time of starting. The capacity of ats is 15hp to 1000hp.

    more..
  • Control Panels

    Get Price Quote

    Control Panels, deep freeze control panel

    more..
  • WPC Wall Panel Wave Board

    Get Price Quote

    WPC Wall Panel Wave Board, Decorative Frosted Glass

    more..
  • 24 Port Power Cat 6 Patch Panel, 568A/B, 1U

    Get Price Quote

    24 Port Power Cat 6 Patch Panel, 568A / B, 1U, Wireless ADSL

    more..
Filter by Locality
top