Warning Siren
Warbling Relay Switch helps in generating a warbling tone from a electric motor siren. It turns a siren on for 4 seconds & off for 4 seconds.Turn ON Time: 4 Seconds,Turn OFF Time: 4 Seconds.
...moreStrobe Light
We offer High Intensity LED Strobe and Flashing Lights suitable for Outdoor Installations & various applications. Our Strobe Lights are made with best quality LED & ABS top cover for better life. Chimney Lights (Aircraft warning lights for chimneys) Crane Strobe Lights (For overhead crane warning) Obstruction Lights
Input Voltage : 12V, 24V, 110V & 220V
...moreSiren Alarm
Our Automatic School Bell System is a simple yet robust. Schools, colleges, coaching classes, offices can use it for automatic bell ringing system. 25 types of bell settings (Periods) can be added for any day including Tea Breaks, Lunch breaks, short recess & Long recess & assembly. Bell duration can be individually set in seconds for example, short bell (3 seconds) and long bell (6 Seconds). There is also a provision for day selection viz Time Table can be defined same for all six days or same for Monday to Friday & special half day schedule for Saturday & Sunday holiday. Apart from automatic bell ringing it has a manual mode, which can be used in case of any deviation from predefined schedule or emergency use.
...moremotor siren
We offer complete range of Electric Siren which are used for fire alarm or in case of emergency alerts. Electric Motor Siren are also called as air raid siren. Electric Siren is basic and integral part of any emergency alert system.
Voltage : 12, 24, 110, 220/240V AC
...moreIndustrial Sirens
Housing:M. S. Powder Coated,Circuit Size:225mm X 200mm (Varies as per Voltage),Tone:Siren Dual Tone,Range:300-400 Meters (Single Speaker),Speaker:P.A. Type,Sound Output:80-85 dB,Input Voltage:2201104824 V AC or 1224 V DC (Any One).
...moreHand Operated Siren
Flasher Electronic Hooter
This is an Audio Visual Alarm, useful for situations where there is requirement for both Audio & Visual Alerts. Benefit of warning led light is that in case machine operator is away, he can still get alerted with Flashing warning light.
...moreEmergency Lights
Emergency Light with Exit Sign Features:- Double Beam Metal Halide bulb / LED 7.5AH Exide Battery Upto 1 Hour backup Automatic ON in case of Power Failure Battery over, under Charge Protection. With Radium exit sign
...moreElectronic Siren
We are offering Electronic Siren
Electric Siren
We offer complete range of Electric Siren which are used for fire alarm or in case of emergency alerts. Electric Motor Siren are also called as air raid siren. Electric Siren is basic and integral part of any emergency alert system.
...moreElectric Motor Siren
We offer complete range of Electric Siren which are used for fire alarm or in case of emergency alerts. Electric Motor Siren are also called as air raid siren. Electric Siren is basic and integral part of any emergency alert system.
...moreBuzzers
Hooter Cut Out Dimensions: 92 X 92 mmInput Voltage: 12v, 24/30v, 48/50v, 110v, 220v / 220v AC Or DC (Any One)Ideal Audible Range: 50 MetersTone: Multitone / Single Tone Buzzers with Volume Control Buzzers with Tone Control Buzzers with acknowledgement switch.
...moreAdvanced Siren Controller
Our Advanced Siren Controller is based on OISD-177 safety standard & Codes of Practices for Emergency Response and Disaster Management Plan (ERDMP) Petroleum And Natural Gas Regulatory Board G.S.R. 39(E) Advanced Siren Controller 14.2.5.9 Siren Codes. The Emergency siren/s should be located suitably to cover the whole area with the operational control within the installation. These should be tested at least once in a week to keep them in working condition. The Emergency siren/s should be located suitably to cover the whole area with the operational control within the installation. These should be tested at least once in a week to keep them in working condition. Emergency siren code should be as follows, namely: – Emergency Level-I: A wailing siren for two minutes. Emergency Level-II and III: Same type of siren as in case of Level – I and II but the same will be sounded for three times at the interval of one minutes i.e.( wailing siren 2min + gap 1 min + wailing siren 2min + gap 1min + wailing siren 2min) total duration of Disaster siren to be eight minutes. ALL CLEAR: Straight run siren for two minutes. TEST: Straight run siren for two minutes at frequency at least once a week Public address system should be provided with message. OISD-STD-117. Control panel shall have different patterns codes as under: FIRE: For fire situation, the siren shall be wailing sound for 2 minutes. DISASTER: For disaster situation, the siren shall be wailing sound for 2 minutes repeated thrice with a gap of 10 seconds. ALL CLEAR: For all clear situation, the siren shall be straight run sound for 2 minutes. TEST SIREN: For testing, the siren shall be straight run sound for 2 minutes. We can also customize this as per customer requirements. Classification of emergencies. Emergencies can be categorized into three broad levels on the basis of seriousness and response requirements, namely:- Level 1 : This is an emergency or an incident which can be effectively and safely managed, and contained within the site, location or installation by the available resources; has no impact outside the site, location or installation. Level 2 : This is an emergency or an incident which – cannot be effectively and safely managed or contained at the location or installation by available resource and additional support is alerted or required; is having or has the potential to have an effect beyond the site, location or installation and where external support of mutual aid partner may be involved; is likely to be danger to life, the environment or to industrial assets or reputation. Level 3: This is an emergency or an incident with off-site impact which could be catastrophic and is likely to affect the population, property and environment inside and outside the installation, and management and control is done by district administration. Although the Level-III emergency falls under the purview of District Authority but till they step in, it should be responsibility of the unit to manage the emergency. Note: Level-I and Level-II shall normally be grouped as onsite emergency and Level-III as off-site emergency.
...moreBe first to Rate