Temperature Baths-Dry Block Calibrators
Get Price Quote
The T-350P, T-650P and T-1200P models control temperature over an insert in order to calibrate thermocouples, thermo resistances, glass thermometers, thermo switches etc. Besides this, the T-1200P model comes with the function of black body target. Besides providing high accuracy temperature values, they also allow the measurement of signals generated by the thermocouples, thermor esistances and thermo switches, which are being calibrated. This possible due to an embedded calibrator specific for these types of signal, including 4-20 mA. They incorporate the function of dry block, standard thermometer and calibrator for RTD and TC sensors, besides mA reading. They present a wide range of programming resources, allowing them to perform automatic calibration of the sensors. In this case, the sensor is placed in the insert and its electrical terminals are connected to the embedded calibrator, the operator defines the calibration points and the number of repetitions, then the process is started so that all the sequence is automatically accomplished. Another way of performing automatic documented calibrations is by means of ISOPLAN calibration software for PC/Windows TM which uses the RS-232 serial port to connect PC to the dry block. With ISOPLAN it is possible to register sensors and instruments of the factory, generate work orders, create and print calibration certificates and reports, that is, it brings all the advantages of computer data management to the calibration environment.
Temperature Baths-Dry Block Calibrators
Get Price Quote
The T-350P, T-650P and T-1200P models control temperature over an insert in order to calibrate thermocouples, thermo resistances, glass thermometers, thermo switches etc. Besides this, the T-1200P model comes with the function of black body target. Besides providing high accuracy temperature values, they also allow the measurement of signals generated by the thermocouples, thermor esistances and thermo switches, which are being calibrated. This possible due to an embedded calibrator specific for these types of signal, including 4-20 mA. They incorporate the function of dry block, standard thermometer and calibrator for RTD and TC sensors, besides mA reading. They present a wide range of programming resources, allowing them to perform automatic calibration of the sensors. In this case, the sensor is placed in the insert and its electrical terminals are connected to the embedded calibrator, the operator defines the calibration points and the number of repetitions, then the process is started so that all the sequence is automatically accomplished. Another way of performing automatic documented calibrations is by means of ISOPLAN calibration software for PCWindows TM which uses the RS-232 serial port to connect PC to the dry block. With ISOPLAN it is possible to register sensors and instruments of the factory, generate work orders, create and print calibration certificates and reports, that is, it brings all the advantages of computer data management to the calibration environment.
Best Deals from Temperature Calibrator
90 degree c dry block temperature calibrator
Get Price Quote
90 degree c dry block temperature calibrator, dry block temperature calibrator