Alarm Cables Dealers in Jaipur

(3 products available)
  • TP FRTEK cables

    TP FRTEK cables

    Get Price Quote

    Our products are completely manufactured using premium raw supplies to make sure they adhere to global management standards of quality. As, our organizations is a suppliers of TP FRTEK cables; purchasers can place wholesale orders for it, and get them at the lowest prices.   Specifications : BS 8519:2010 - Code of practice for Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications. BS 5839-1:2008 - Code of practice for system design, installation, commissioning and maintenance – Fire Detection / Fire Alarm systems for buildings. BS 5839-8:2008 - Code of practice for the design, installation, commissioning and maintenance of Voice alarm systems. BS 5839-9:2011 - Code of practice for the design, installation, commissioning and maintenance of Emergency voice communication systems. BS 5266-1:2005 - Code of practice for the emergency lighting of premises. BS 7629-1:2008 - Specification for thermosetting insulated, unarmoured, screened fire-resistant cables of rated voltage 300/500V, having low emission of smoke and corrosive gases when affected by fire. BS 7846:2009 - Specification for thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000V, having low emission of smoke and corrosive gases when affected by fire. BS 8491:2008 - Method of assessment of fire integrity of power cables with diameter greater than 20mm (as per BS 8519:2010). Retain Circuit integrity at 600/1000V under Simultaneous application of constant Flame at 850oC, Direct Mechanical Impacts & High Pressure Water Jet. The test duration is expressed in minutes depending on the required time duration of the application as follows : Category 1 - 30 minute Category 2 - 60 minute Category 3  - 120 minute BS 8434-2:2009 - Fire performance “Enhanced Test” as per BS 5839 Part 1, 8 & 9 (For conductor size upto and including 4sq mm) Method for assuessment of fire integrity of small cables for use in emergency Circuits. Retain Circuit Integrity at 930oC.Duration of test is 120 mins. Initial 60 mins. with Fire and Impact followed by an additional 60 mins. with Fire, Impact and Water Phase.

    more..
  • Fire Alarm Cable

    Fire Alarm Cable

    Get Price Quote

    • Voltage Rating: 300/500V
    • Temperature Range: -30°C to + 70°C

    These cables are used in high rise buildings, commercial complexes, schools and educational institutions, hospitals, etc. for the connection with security systems like smoke detectors, emergency lightings, exit signboards and fire command center. These cables are used where the fire safety is utmost important.

    more..
  • Best Deals from Alarm Cables

  • TP FRTEK cables

    TP FRTEK cables

    Get Price Quote

      Fire Resistant / Fire survival – Applicable Standards British Codes and Specifications BS 8519:2010 :Code of practice for Selection and installation of fire-resistant power and control cable systems for life safety and fire-fighting applications.BS 5839-1:2008 :Code of practice for system design, installation, commissioning and maintenance – Fire Detection / Fire Alarm systems for buildings.BS 5839-8:2008 :Code of practice for the design, installation, commissioning and maintenance of Voice alarm systems.BS 5839-9:2011 :Code of practice for the design, installation, commissioning and maintenance of Emergency voice communication systems.BS 5266-1:2005 :Code of practice for the emergency lighting of premises.BS 7629-1:2008 :Specification for thermosetting insulated, unarmoured, screened fire-resistant cables of rated voltage 300/500V, having low emission of smoke and corrosive gases when affected by fire.BS 7846:2009 :Specification for thermosetting insulated, armoured, fire-resistant cables of rated voltage 600/1000V, having low emission of smoke and corrosive gases when affected by fire.BS 8491:2008 :Method of assessment of fire integrity of power cables with diameter greater than 20mm (as per BS 8519:2010). Retain Circuit integrity at 600/1000V under Simultaneous application of constant Flame at 850°C, Direct Mechanical Impacts & High Pressure Water Jet. The test duration is expressed in minutes depending on the required time duration of the application as follows: Category 1 :30 minute Category 2 :60 minute Category 3 :120 minute BS 8434-2:2009 :Fire performance “Enhanced Test” as per BS 5839 Part 1, 8 & 9 (For conductor size upto and including 4sq mm) Method for assuessment of fire integrity of small cables for use in emergency Circuits. Retain Circuit Integrity at 930°C.Duration of test is 120 mins. Initial 60 mins. with Fire and Impact followed by an additional 60 mins. with Fire, Impact and Water Phase.

    more..