Wound Core Transformer
Features of our CRGO Wound Core: Reduces maintaining and storage cost. Assembly time is highly reduced. Enhances better rating for transformers. Higher flux density. Lower destruction factor can be achieved. Noise level reduction. Enables a favorable assembly for the upper yoke.
...morewound core
The manufacturing of strips wound cores is a specialized process, which requires a high degree of precision. These cores are manufactured from selected coils of CRGO electrical steel to yield closely controlled electro-magnetic characteristics and dimensional accuracy. Cores are wound as loops (two halves with overlapping ends joined together to form loop in multiple layers of the wound core) after slitting is done as per the required shape depending upon the rating and specification of the transformer on design parameters on the Unicore wound making machines. The Machine automatically stops when the pre-decided dimension is reached. The cores are stress-relief annealed to restore the magnetic properties. The cores are bonded where necessary, to provide increased firmness. Features Reduces maintaining and storage cost. Assembly time is highly reduced. Enhances better rating for transformers. Higher flux density. Lower destruction factor can be achieved. Noise level reduction. Enables a favorable assembly for the upper yoke.
...moretransformer laminations
Transformer laminations As manufacturing of transformer lamination involves a high degree of precision engineering, we always make every effort hard for significant quality checks of burr level, stack height, dimension and required weight.
...moreTransformer Core
Transformer core a high degree of precision engineering, we always make every effort hard for significant quality checks of burr level, stack height, dimension and required weight.
...moreToroidal Cores Transformer
We are offering toroidal cores transformer. Features high strength compact design corrosion resistance durability
...moreToroidal Core
Toroidal core is manufactured by our experts using high grade CRGO steel and latest technology. The offered core is used in the electrical devices for controlling the heavy loss and helps in reducing the high current. This wide range is properly tested on various quality parameters by our quality controllers. We offer this Toroidal Core (CRGO) in both specific and customized options as per the customer needs.
...moreThree Phase transformer
Fittings: Rating and Diagram Plate Primary & Secondary Bushings Lifting Lugs Air release plug Filter Valve Silica gel Breather Oil level gauge Earthing terminals Conservator with drain plug Oil filling hole with cap Thermometer pocket with dial type thermometer Cover lifting eyes Explosion vent Stiffener on all sides of tank body Pulling eyes Roller arrangement Skid base Optional Fittings: Terminal connectors, Tapping Switch (OLTC), Arcing Horns, Lightning Arrester & Self-protection system with MCCB, HV fuse, Oil Immersed Circuit Breaker
...moreStacked Core Transformer
At MEIPLs ultra modern facility plant we can meet today requirement of - Horizontal Step Lap Vertical Step Lap Conventional Designs Reactor Core PT Lamination.
...moreStackcore
We cut; punch and V notch the Stack core/Transformer Lamination/Cut Lamination for Distribution & Power Transformer in our CNC Cut to Length Machines with auto stacking facility. We have the facility to cut the CRGO lamination in geometrical shapes with 90° & 45° cutting angle, width up to 640 mm and length up to 3500 mm As manufacturing of transformer lamination involves a high degree of precision engineering, we always make every effort hard for significant quality checks of burr level, stack height, dimension and required weight. At MEIPL’s ultra modern facility plant we can meet today’s requirement of - Horizontal Step Lap Vertical Step Lap Conventional Designs Reactor Core PT Lamination
...moreSlit Coils Transformer
We are offering slit coils transformer. Primary and essential procedure for any cut lamination is slitting of crgo mother coils in various widths as per the requirement. Excellence & accurateness start only from slitting stage, we guarantee maximum 10 micron burr by slitting the coils in our new cnc slitting line. We have the facility to slit minimum from 60 mm to maximum 1100 mm.
...moreSlit Coils
Slit coils Primary and essential procedure for any cut lamination is Slitting of CRGO Mother coils in various widths as per the requirement.Excellence & accurateness start only from slitting stage, we guarantee maximum 10 micron burr by slitting the coils in our new CNC Slitting line.We have the facility to slit minimum from 60 mm to Maximum 1100 mm.
...moreSingle Phase Transformer
Fittings: Rating and Diagram Plate Primary & Secondary Bushings Pole Mounting Brackets Tank Grounding Provision Lifting Lugs Pressure Relief Device Optional Fittings: Terminal connectors, Arcing Horns, Lightning Arrester & Self-protection system with MCCB, HV fuse, Oil Immersed Internal Circuit Breaker
...morePower Transformer
Fittings: Silicagel Breather Magnetic Oil level gauge Earthing terminals Conservator with drain plug Dial Type Thermometer Explosion vent with equalizer pipe Pulling eyesRoller arrangementSkid base Winding Temperature Indicators Marshaling Box Arcing Horns Thermometer Pocket with Dial Type Thermometer
...morePole mounted Transformer
MEIPL manufactures Single Phase Oil Filled Distribution Transformers with robust cylindrical construction Pole Mounted Type from 5 KVA to 25 KVA ratings in Aluminum and Copper wound...
...morePrestress Cement Concrete Pole
These prestress cement concrete ( PCC ) poles are also used for maintaining the different electricity distribution needs . These PCC poles are essentially made of concrete which are inevitably less costly and more economically maintainable than the conventional steel poles. They are of two types depending upon the end use of poles-low tensile and high tensile line. The latter is primarily used for transmission/distribution of electricity. These poles come in 8mtr, 9mtr & 11mtr length and 200 kg to 400 kg working load capacity . Raw material used : High tensile wire Cement Galvanized iron wire Stone aggregate Manufacturing process : Prestress cement concrete poles are essentially made of concrete. High tensile wire is inserted into the pre-designed moulds and stretched to reach a certain tension . Galvanized wire is fixed inside the mould for earthing following which a right proportion of concrete mix is poured. Then , the concrete is compacted through vibration to produce high strength concrete poles.
Country of Origin : India
Type : Prestressed Concrete Pipe
...morePcc Poles
PCC poles used for maintaining the different electricity distribution needs . These PCC poles are essentially made of concrete which are inevitably less costly and more economically maintainable than the conventional steel poles. They are of two types depending upon the end use of poles-low tensile and high tensile line. The latter is primarily used for transmissiondistribution of electricity. These poles come in 8mtr, 9mtr & 11mtr length and 200 kg to 400 kg working load capacity .
...moreOutdoor VCB Panel
Simple, compact & sturdy Reilable vacuum technology for switching Maintenance free and high reliability Complies to IP55 Degree of Protection Long electrical mechanical life Conforms to IEC 62271-100 IS 13118 Compatible for remote and SCADA operations
...moreoutdoor vcb
Simple, compact & sturdy Reilable vacuum technology for switching Maintenance free and high reliability Complies to IP55 Degree of Protection Long electrical mechanical life Conforms to IEC 62271-100 / IS 13118 Compatible for remote and SCADA operations Application Public Distribution Networks Rapid auto-reclosing applications Switching duties for Capacitor, Transformers, etc. Industrial distribution Suitable for mining application
...moreIndustrial Transformer
Industrial transformer Three Phase Oil Filled Distribution Transformers are supplied both in CRGO versions from 10 KVA to 2500 KVA rating transformers with robust design and sturdy construction. Thermometer pocket with dial type thermometer.
...moreindoor vcb
Compact, sturdy with an adaptable design Maintenance free & high reliabilityTotal compartmentalized design. Provision of discharge flap with wire meshProvision of safety interlocks Long electrical and mechanical life Conforms to IEC 62271-100 & 200/ IEC 606094 / IS 13118 Compatible for remote and SCADA operations Application Distribution Networks Industrial distribution Rapid auto-reclosing applications Switching duties for Capacitor, Motors, Auxiliary Generator Units for Power Plants
...moreepc transformer
We are offering epc transformer. Our epc division offers comprehensive engineering, procurement and construction services in areas of power transmission and distribution. We execute projects on turnkey basis for extra high voltage transmission lines, ais gis substations up to 400kv and distribution sub-stations up to 33kv coupled with modern day smart grid solutions and scada systems. Our strong presence in product business has enabled us in understanding the complete requirements of customers thus becoming a total solution provider to them.
...moreElectrical Laminations
Electrical laminations in geometrical shapes with 90° & 45° cutting angle, width up to 640 mm and length up to 3500 mm As manufacturing of transformer lamination involves a high degree of precision engineering, we always make every effort hard for significant quality checks of burr level, stack height, dimension and required weight.
...moreElectrical Circuit Breaker
MEIPL is a one stop destination where you can avail a huge assortment of CSP Circuit Breakers. The company is actively engaged into the business of manufacturing and supplying CSP Circuit Breakers. Our Certifications reflect the genuineness of our CSP Circuit Breakers and other services offered by us. These breakers have found extensive application in maintaining the electrical circuit during overloads. Our breakers have the track record of protecting and safeguarding several circuits from getting damaged. These CSP Circuit Breakers with bypass facility detect and interrupt faults.
...moreCRGO Transformer Lamination Core
Crgo transformer lamination core to Customer specification for single phase and three phase distribution transformer applications By using Metglas® amorphous metal. Epoxy coating is applied to the some parts of the cores in order to get mechanical rigidity. And finally we can get the 80% lower No load losses as compare to CRGO Lamination.
...moreBe first to Rate
Rate ThisOpening Hours