Trivector Solar Power Plant
Maximize energy output, reduce maintenance cost, and benefit from predictable expenses over the life of your PV power plant assets with Trivector Power Solutions comprehensive suite of O&M solutions. A FACILITES REPORTING AND MONIORING A.1 MONITORING OF THE PLANT A.2 PREPERATION OF DAILY REPORTS A.3 CALCULATION OF PERFORMANCE RATION AND AVAILABELITY OF PLANT A.4 COORDINATION WITH GRID TEAM FOR GRID AVAILABELITY A.5 REGISTERIATION OF DAILY ACTIVITEIS A.6 INFORMATION OF INCIDENCE A.7 PREPERATION OF INCIDENCE REPROT A.8 PREPERATION OF EXTIMATION FOR REPAIRING OF LOOSE OF FOR INSURANCE A.9 DAILY,WEEKLY,MONTHLY TECHNICAL REPORTS B. FACILITIES PREVENTIVE MAINTENANCE B.1 PREVENTIVE MAINTENANCE B.2 DAILY VISUAL INSPECTION OF EQUIPMENTS INSTALLED IN PLANT B.3 DAILY VISUAL INSPECTION OF PV STRUCTURE AND PV MODULES B.4 DAILY INSPECTION OF FIRE FIGHTING EQUIPMENTS B.5 STRING CURRENT MEASURMENT AT SMB LEVEL B.6 DAILY VISUAL INSPECTION OF CIVIL INFRASTRUCTURE B.7 PM OF INVERTER , HT ,LT PANELS, Metering Panel, ACCB, FIRE FIGHTING EQUIPS AND OTHER EQUIPS B.8 PREPERATION OF REPORTS AND REPORT FOR CORRECTIVE WORKS B.9 PV PANEL CLEANING (TWICE/MONTH) B.10 SUPPLY OF WATER FOR CLEANING B.11 SUPPLY OF MANPOWER FOR CLEANING B.12 TOOLS AND TACKLES B.13 CONSUMABLE ITEMS REQUIRED IN DAILY AND PREVENTIVE WORKS C CORRECTIVE MAINTENANCE IN PV C.1 MAJOUR FUNCTION FAILURE C.2 FAILURE OF DC BREAKER , AC BREAKER MACHANISM & IGBT IN INVERTER D REPORTING AND MANAGEMENT OF CORRECTIVE WORKS D.1 REPORTING FOR BREAKDOWN OF EQUIPMENTS D.2 PLANNING FOR CORRECTIVE WORKS D.3 REPORTING IF ANY HEAVY MECHIONERY REQUIRED FOR CORRECTIVE WORK D.4 PROVIDING EXTRA RECOURCES FOR CORRECTIVE WORKS D.5 TOOLS REQUIRED FOR CORRECTIVE WORKS D.6 CORRECTION AND MAKING SYSTEM IN GOOD CONDITION E FACILITIES PREDICTIVE MAINTENANCE E.1 PREDICTIVE MAINTEANC OF EQUIPMENTS E.2 EXTRA LABORATORY WORKS PV MODULES ESSEYS E.3 PLANNING FOR PREDICTIVE WORKS E.4 THERMOGRAOGY INSPECTION OF PV PANELS & ALL ELECTRICAL BOARD E.5 I-V CURVE TEST AT STRING LEVEL E.6 SHUTDOWN APPLICATION FOR CARRYING OUT PREDICTIVE WORKS F CONSUMABLES PARTS MANAGEMENT F.1 CONSUMABLE ITEMS ( CONDITIONAL) AND PROCOURMENT G SPARE PART MANAGEMENT G.1 PREPERATION OF SPARE PARTS LIST G.2 MANAGEMENT OF SPARE PARTS G.3 WARE HOUSING OF SPARE PARTS G.4 SPARE PART AVAILABILITY AND PROCUREMENT
...moreNet Metered Rooftop Solar Power Plant
Based on available roof area solar PV panels will be installed on the roof (RCC or Tin Shed) of the building. The output of the panels (DC electricity) connect to the power conditioning unit / inverter which converts DC to AC. The inverter output will be connected to the control panel or distribution board of the building to utilize the power. The inverter synchronizes with grid and also with any backup power source to produce smooth power to power the loads with preference of consuming solar power first. If the solar power is more than the load requirement, the excess power is automatically fed to the grid. For larger capacity systems connection through step up transformer and switch yard may be required to feed the power to grid. Rooftops PV systems on residential buildings typically feature a capacity of about 1 to 20 kilowatts (kW), while those mounted on commercial buildings often reach 500 KW or more Grid Connected Solar Power Plant under “Net Metering” Scheme The concept of Net Metering involves recording the net energy between export of generated energy and import of energy from distribution licensee for a given period of time. If more energy is exported to the grid than imported, then the distribution licensee pays the consumer at tariff decided by State Electricity Board. If more energy is imported from the grid than exported, then the consumer pays the distribution licensee. Key Features of rooftop solar power plant installations Accelerated Depreciation Benefit @ 100% (Which helps offset your tax liability). Easy Integration to your existing utilities. Convert unused roof space into a valuable energy resource. Rooftop Solar Investment is returned in less than 5 years. No interconnection problems, No wheeling charges and transmission losses. Insulation from likely increase in energy cost. Savings in diesel as well as replacing the polluting, expensive and noisy diesel generator. Long Life (25 years). Low operation & Maintenance. Clean, Quiet and Visually Unobtrusive. Long term energy security. Applications Residential Universities and colleges Commercial buildings. Hospitals & Hotels Industrial Sheds Railway Lighting / Signaling Telecom Tower ATM & Bank School / Colleges Petrol Pumps
...moreLV & HV Switchgears
We provide comprehensive range of products, solutions and services for meeting the requirements in the areas of energy, automation, infrastructure and agriculture, as well as for different industries. We offer design, supply, consultancy, installation and testing of following equipment. SWITCHGEAR & CONTROL Vacuum Circuit Breakers Air Circuit Breaker Ring Main Unit (RMU)-VRE, VRN, VCE Control panel PCC, MCC, ACDB, DCDB panels AJB EARTHING Earth Pit Renewal of Earth Pit Earth Pit Testing Clamping and cleaning of copper/G.I earthing strip Laying of copper/G.I earthing wire Power Cable & Cable Accessories HT/LT Cables Solar Cable Cable Accessories HT / LT Cabling by digging trench and on prepared M.S rack or M.S support or on wall Fault Finding of underground cable End Termination of LT cables Indoor/Outdoor Joint Kit TRANSFORMER (Oil Filled & Dry Type) Power Transformer Distribution Transformer Trasformer Oil Testing & Filteration Transformer Overhauling
...moreGround Mounted Solar Power Panel
Trivector Power Solutions provides a range of customized solar PV installation from concept and design to commissioning for residential and commercial application .These installation can be designed based on the need of the customer and installed at site by out experts. The scope will include system design, material specification, Plant Layout, supply of component, system integration /installation and commissioning.
...moreElectrical EPC Transformer System
Engineering Design & Consultancy: We offer our clients a full HV, MV and LV turnkey facility right through from design to handover including: Full system specification Feasibility studies Condition Assessment studies Protection relay coordination studies Short Circuit level calculations Power factor correction studies Project Management Design and Build contracts Complete Handover documentation Supply, Installation & Commissioning of HV and MV equipment: We provide installation and commissioning of following range Main Switchgear( Up to 33 KV) Installation (Transformer, Breaker, CT’s, PT’s, Battery tripping unit, Power Factor correction Panel, Protection Relay’s. Electrical Distribution Panel. Bus Duct & Riser Feeders. Motor Control Centers / Motor Controls. Power & Control Wiring for Processing and Manufacturing equipment Power for Commercial and Industrial Projects. Integrated Control and Protection Panels for Generator Interface Protection. Cable laying, terminations and testing including sheath testing and insulation testing. Earthing
...moreBuilding Electrification Control System
New Installations and Annual maintenance contract (AMC) works Supply & Release of LT/ Special LT power supply work on turnkey basis including liasoning with AVVNL, JVVNL and JDVVNL. Supply installation, testing & commissioning of HT metering KIOSK, RMU, HT Breaker,Transformer, LT Control panel and DG set. Supply, laying & joining of HT/ LT Cables. Supply & erection of overhead 11KV / 22 KV/ 33 KV HT Lines. Transformer oil filtration work. Insulation and earth resistance testing. Supply and installation of traditional/ chemical earthlings. Maintenance of 2 pole/ 4 pole structures including painting of poles and structure. To provide annual inspection reports required for electrical inspection department. Supply & Erection of street light, Flood light and high mast. Supply & installation of cable trays. Supply & Installation of 11 KV/ 22 KV/ 33 KV GOD, DO & LA Set. Supply & Installation of APFC Panels for power factor improvement. Supply & Installation of Capacitor bank. Liasoning for enhancement / Reduction in HT load. Replacement of existing CTs in HT metering KIOSK by new CTs. Supply, Installation, testing, statutory approvals & commissioning of Indoor/ Outdoor HT substations, on turnkey basis including liasoning with Discoms for the Supply & Release of HT Power Supply.
...moreSolar Home Lighting System
Solar Lantern
Solar Street Light
Solar Water Heater
Solar Water Pump
Be first to Rate
Rate ThisOpening Hours