Singla Cables Bari Brahmana, Jammu, Jammu & Kashmir

  • underground cable

    underground cable

    Request for Price

    Get Best Price
  • Telephone Drop Wire

    Telephone Drop Wire

    Request for Price

    Feature : Durable , Moist proof

    Get Best Price
  • telecom duct

    telecom duct

    Request for Price

    This is Permanently Lubricated HDPE Telecom Duct used for laying & protection purpose of Underground Optical Fiber Cable & Jelly Filled Telecom CablesApplication   Material: plastic Color: green Widely used in telephone line covering     Features Flexible Resistance to crush and compression High strength

    ...more
    Get Best Price
  • Signaling Cable

    Signaling Cable

    Request for Price

    We are offering signaling cable, which is made in accordance with international quality accepted standards. High strength, effective performance, flexibility and durability are synonyms to the range of signaling cable we offer in the markets. Moreover, we make these available to the clients in varied quantities to suit the specification of the esteemed clients. specifications : conductor sizes : 1.13mm to 2.80mm diametercable sizes : 2 crore to 100 crore with 1.0sqmm to 50sqmm applications : suitable for use on ac systems (earthed or unearthed) for rated voltage upto 1100 voltsideal to be used on dc systems for rated voltage upto 1500 volts

    ...more
    Get Best Price
  • Signal Cable

    Signal Cable

    Request for Price

    Signal cable and control cable are both types of flexible data cable used in data transmission applications which demand superior signal protection. These applications require some of the smallest, most flexible, and highly screened cables on the market. Signal cables are used in a multitude of industries and can be found in everything from computers and medical equipment to appliances. Features Temperature resistance High tensile strength Superior efficiency

    ...more
    Get Best Price
  • railway signalling cables

    railway signalling cables

    Request for Price

    Signalling Cable suitable for the rail industry – Cleveland Cables Type A, B, C, D and E signalling cables can be used on and around railway tracks. The signalling cables are used for free wiring, control and signal transmission.   Application   Used for signalling circuits in railway networks   Connect the signalling equipment center to the track-side equipment   Features   Excellent resistance to high and low temperature Resistance to oil, damp and humid weather conditions Low reduction factor  

    ...more
    Get Best Price
  • railway signaling cable

    railway signaling cable

    Request for Price

    Get Best Price
  • Pvc Cables

    Pvc Cables

    Request for Price

    In these cables conductors are covered with PVC insulation & the are paired according to colour sequence and also sheathed with PVC. These are used for connection purpose mainly in Exchanges to D.P. Box.   Application For control devices, e.g. Machine tools, flow and assembly lines, conveyor systems, production lines and plant construction, switchgear cabinet construction, communication technology equipment, household appliances, generators, transformers and mechanical engineering, switchgear and control engineering, electrical engineering, installation and packaging technology, textile, woodworking electrical and data processing, in cleaning equipment, automotive industry, automation technology, press and mold making, printing and paper machine construction, surface technology, iron and steel production industry, beverage filling plants, chemical industry, intrinsically safe circuits, control units in explosion- CNC machining centers, lamps and lighting technology   Features   Strong and lightweight Easy to install Durable Cost-effective Safe material Fire resistant Good insulator Versatile  

    ...more
    Get Best Price
  • LV Control Cables

    LV Control Cables

    Request for Price

    1100 Volts grade-BASEC /KEMA/(CPRI/ERDA Tested ) Control Copper cable, Solid Standard Conductor PVC / XLPE Insulated Cores Laid up, PVC / FR/ ST2 / FRLS/LSZH Tape Extruder inner sheath Unarmoured/ Armoured extruded PVC/ FR/ ST2/ FRLS/LSZH Sheathed cables from 2.5 sq. mm to 1000sq. mm and in 2/2/3.5/4 Core as per IS 1554/IS 7098 (Part-1) 1988 and generally confirming to IEC 60502-1/BS 5467/ BS 6724   Features   High safety performance Durability Rugged design Easy installation application Infrastructures Automation Lighting Sound and security Video surveillance Fire alarm  

    ...more
    Get Best Price
  • LT Power Cable

    LT Power Cable

    Request for Price

    An assembly of one or more electrical conductors held together with an overall sheath is known as LT power cables. This assembly is used for electrical power transmission and distribution purpose.These cables are designed and manufactured as per current, voltage, operating maximum temperature and purpose of applications desired by a customer.   Application   LT power cable may be installed as permanent wiring within buildings, run overhead, buried in the ground or exposed. And Flexible power cables are used in mobile tools, portable devices, and machinery.     Features   High on Current Rating High on Overload Capacity High on Short Circuit Rating Light in Weight with small Bending Radius Lower Di-electric Constant & Power Factor Better Impact, Abrasion, Corrosion Resistance Easy to join and terminate Non-hygroscopic insulation unaffected by moisture Non-migration of compound permitting vertical installation Good ageing properties Unaffected by vibration  

    ...more
    Get Best Price
  • Lt Aerial Bunched Cables

    Lt Aerial Bunched Cables

    Request for Price

    Aerial Bunched Cable (ABC) is a very novel concept for overhead Power distribution. ABC provides higher safety and reliability compared to bare conductor overhead distribution system. The other advanctages are lower power losses and system economy by reducing installation, maintenance and operation cost. This system is ideal for rural distribution and specially suitable in difficult terrains like hilly areas, forest and coastal areas etc. ABC is also considered as a better choice for power distribution in densely populated areas where laying of underground cable is either difficult or extremely expensive. This is attributed by narrow lanes and by-lanes of congested urban areas. Needless to mention that ABC is a better choice due to the flexibility of re-routing demand, should there be any changes in urban development plan. Application Easier Installation particularly in congested, forest or Hilly areas. Saving in cost of Poles, Insulators, cross-arms etc. Human Safety in case of accidental contacts. Water proof system, no corrosion.Syatem reliability hence customer satisfaction. Reduced clearance.

    ...more
    Get Best Price
  • Lan Cable

    Lan Cable

    Request for Price

    A local area network (LAN) is a computer network that interconnects computers within a limited area such as a residence, school, laboratory, university campus or office building. By contrast, a wide area network (WAN) not only covers a larger geographic distance, but also generally involves leased telecommunication circuits.   application Data Center Office Local Area Network Industry Building technologies & automation   Features   Coverage area is generally a few kilometers. In LAN you can run the multiple devices to share a transmission medium. You can use the different topology mainly bus and ring in LAN. The communication quality is better IN LAN, the transmission error rate are low as compare to WAN. LAN support a variety of communications transmission medium such as a Ethernet cable (thin cable, thick cable, and twisted pair), fiber and wireless transmission. A LAN usually has low cost, installation, expansion and maintenance and LAN installation is relatively simple, good scalability.  

    ...more
    Get Best Price
  • Jumper Wire

    Jumper Wire

    Request for Price

    We offer to the clients Jumper Wire, which is high on demand in the national and international markets. Jumper Wire is actually a tinned copper conductor with 0.5 mm diameter PVC Insulation Cover. Obtainable in safe packaging and reasonable prices, clients have been Jumper Wire. Attributes : Long functional lifeChemical resistantDurableResistance to heatAbility to withstand high temperatureEasy to install Used As : Signal distributors

    ...more
    Get Best Price
  • Jelly Filled Telephone Cable

    Jelly Filled Telephone Cable

    Request for Price

    Solid Annealed Copper, Polythene Insulated Petroleum Jelly Filled Poly-Al Laminated Moisture barrier,Polythene Sheathed Unarmoured/ Armoured Polythene jacketed as per DOT specification   Application   This type of cable is meant for inter exchange and for local network use. This cable may be unarmored/armored type   Features   Ideally suited for extreme hot & cold weather condition Ideal for water logging areas Highest clarity in communication Absence of cross talk Free from dermatic hazard Easier to handle and less maintenance Free from rodent attack  

    ...more
    Get Best Price
  • Jelly Filled Quad Cable

    Jelly Filled Quad Cable

    Request for Price

    We are offering jelly filled quad cable, which is designed to suit the precise requirements of the esteemed clients. Jelly filled quad cable offered by us is obtainable at highly competitive rates. Jelly filled quad cables are extensively used for axle counter installations ideal to be used in electrified areas. key featuresavailable in 4 and 6 quadsarmoured constructionstandards conductor sizes : 0.9mm & 1.4mm diameterapplicationsdirect burial applicationideal to be used on ac systems((earthed or unearthed) for rated voltage up to and including1100 voltsused in dc systems for rated voltage up to and including 1500 volts on earth construction : conductor : each conductor consists of round wire of annealed high conductivity copper.insulation : each conductor is insulated with solid medium/ high density polyethylene insulation.quadding : four insulated conductors stranded to form a star quad, two conductors diagonally opposite forming one pair and the remaining two diagonally opposite conductors forming the second pairs of the quad.laying up: the quads are assembled to form a symmetrical core with a right hand lay. Polyethylene strungs of required diameter may be used as fillers, if necessary, for proper circular core formation.filling and core wrapping : the cable core is fully filled with water resistant comound which is compatible with the polythene insulation of the conductors. The filled cable core is wrapped with at least one helical or longitudinally polythene tape.poly-al laminate moisture barrier : aluminium tape, coated with polythene on both sides is applied longitudinally over the cable core with a specified overlap. The taoe is seased and bonded to the inner surface of the polythene sheath.sheathing : the screened cable core is sheathed with black polythene compound as per bs:6234screening and protection : the cable core with inners sheathis surrounded by a reasonably close fitted screen of aluminium in the form of wires/strips/welded aluminium tubing. The aluminium screen is wrapped with a single layer of woven tape inpregnated with barium chromate with a specified overlap.intermediate sheath : further protection of screening is provided bby eztryded pvc/pe sheath over screening.amouring : the cable is armoured with two applications of galvanized steel tape each applied helically with specified gap. The second tape covers the gap left by tge first tap.jacketing : the armoured cable is fibally jacketed with black pvc/pe compound meeting the requirement of specification technical details conductor diameterconductor resistance at 20oattenuations at 20o0.90 mm28 (each core) ω hm/km (max)4.40 db/km (max. Avg.) at 150 khz1.456 (loop) ω hm/km (max) 23.2 (loop)ω hm/km (max)2 db/km (max. Avg.) at 300-3400hz0.3 db/km (max. Avg.) at 0.8 khz0.8 db/km (max. Avg.) at 5 khz1.3 db/km (max. Avg.) at 21khz2.5 db/km (max. Avg.) at 150 khz mutual capacitancecapacitance unbalance (800 hz to 1000hz)50±2.5 nf / km (avg.)50±6 nf (individual)pair to pair300pf/km (max.)pair to earth1500 pf/km (max. Avg) insulation resistance 5000 mega ohms / km (min.) 0.90 mmeflext : 150 khz 55db/km ind. (min.) 67.8 db/km (rms) ()min.next : 55 db at 150khz1.4 mmeflext : at 0.8 khz, 5khz, 21khz & 150 khz 60.0 db/km ind. (min.) 70.8 dbkm (rms) (min.) at 150khznext : 55 db at 0.8khz, 5khz, 21 khz & 150 khz

    ...more
    Get Best Price
  • Instrumentation Cable

    Instrumentation Cable

    Request for Price

    Standard / Solid Copper conductor , PE/PVC/HR-PV/XLPE/ Silicon /FR-XLPE Insulated each pair/Triad laid up shielded individually with Mylar / Drain Wire/AL Mylar, all pair / Triads then laid up together overall shielded with Mylar / Drain Wire/AL Mylar, PE/PVC/FRLS/PVC ST2/ LSOH Inner Sheathed Unarmoured / GI Steel round Wire/ Strip/ GI Steel Wire braided ( Armoured), PVC/ FR/FRLS/ PVC T2/ LSOH Outer Sheathed From 2 Pair/ Triad to 61 pair/ Triad in Sizes 0.5 sq. mm to 2.5 sq.mm   Application   Savings on material, labor and maintenance with cables rated for exposed runs — no need for conduit Superior electrical performance and longer runs in dozens of different environments Assured, flexible installation connections with all the necessary ratings   Features   Jacket options for excellent resistance to oil, outdoor sunlight/UV, flame and extreme temperatures Insulation options for excellent wet electrical performance, oil and chemical resistance and extreme temperature flexibility Conductor options to provide increased flexibility, greater flex life and corrosion resistance

    ...more
    Get Best Price
  • HDPE Telecom Ducts

    HDPE Telecom Ducts

    Request for Price

    We are offering hdpe telecom ducts, which are manufactured using high quality. Hdpe telecom ducts are extensively used for laying and protection of jelly filled telecom cables and underground optical fiber cable. Moreover, these hdpe telecom ducts are obtainable at most competitive rates. features : heat resistantdurablelonger service lifeability to withstand high temperaturechemical resistantease of installation in demand by : it industrytelecom industry .

    ...more
    Get Best Price
  • hdpe telecom cable ducts

    hdpe telecom cable ducts

    Request for Price

    Get Best Price
  • Galvanized Steel Wires

    Galvanized Steel Wires

    Request for Price

    Get Best Price
  • Dry Core Telephone Cable

    Dry Core Telephone Cable

    Request for Price

    By keeping a track of latest market development and demand, we are successfully ranked amongst the best organization for providing the finest quality Dry Core Telephone Cable.     Features   Chemical resistance Low friction jacket for easy pulling Temperature resistance   Application   It is general purpose telephone cable generally used for Laying in Exchanges and In-house connections.  

    ...more
    Get Best Price
  • cat cable

    cat cable

    Request for Price

    Cat5 cable is broken into two separate categories: Cat5 and Cat5E cables. Cat5 has become obsolete in recent years, due to its limitations compared to Cat5E and Cat6 cables. Although the Cat5 cable can handle up to 10/100 Mbps at a 100MHz bandwidth (which was once considered quite efficient), the newer versions of Cat cables are significantly faster. Category 5 cable is used in structured cabling for computer networks such as Ethernet over twisted pair. The cable standard provides performance of up to 100 MHz and is suitable for 10BASE-T, 100BASE-TX (Fast Ethernet), and 1000BASE-T (Gigabit Ethernet).   Features   Tested to 100 MHz Applicable to most LAN topologies, suitable for 4 and 16 Mbps UTP Token Ring Systems Meets and exceeds IEEE 802.3 10 BASE-T Ethernet, NEMA “Low-loss extended frequency”, EIA/TIA 568 Commercial building wiring standard. UL NEC CM (non-plenum) or CMP (plenum) rated, CSA PCC FT4 or FT6 rated.  

    ...more
    Get Best Price

Be first to Rate

Rate This

Select the service for which you are writing review for this business

How would you rate the business?

What would you like other to know about this business, based on your experience?

Minimum 20 characters!

About the Company

  • Primary Business Manufacturers
  • Secondary Business Type Exporters / Wholesale Suppliers
  • Year of Establishment 2011

Opening Hours

  • SUN : Closed
  • MON : 9:30 AM - 6:30 PM
  • TUE : 9:30 AM - 6:30 PM
  • WED : 9:30 AM - 6:30 PM
  • THU : 9:30 AM - 6:30 PM
  • FRI : 9:30 AM - 6:30 PM
  • SAT : 9:30 AM - 6:30 PM
Singla Cables is Manufacturers of Jelly Filled Telephone Cable, Jelly Filled Quad Cable, Telephone Drop Wire, Signaling Cable, Jumper Wire, HDPE Telecom Ducts, Drop Wire, Industrial Cables, Industrial Wires, jelly cables from Jammu, Jammu & Kashmir.
Read More »

Contact Information

Singla Cables

  • Mr. Maneesh Singal
  • Lane No-2, Phase 2nd, SIDCO Industrial Complex, Bari Brahmana, Jammu (J&K), Jammu & Kashmir
top