Pendulum Impact Tester (Model - IT 30 )
Get Price Quote
1 Piece (MOQ)
The pendulum Impact Tester, Model IT-30 is designed for conducting Izod, Charpy test. The test methods confirm to BS:131:PART 4-1972 (Amended 15 Aug. 1993) BSEN:10045-2:1993. The pendulum is mounted on antifriction bearings. It has two starting positions, the upper one for Charpy the lower one for Izod testing. On release, the pendulum swings down to break the specimen & the energy absorbed in doing so is measured as the difference between the height of drop before rupture of the test specimen and is read from the maximum pointer position on the dial scale. (It is read on digital readout in case of electronic machines). There are two strikers and one combined support anvil available for fitting in to the pendulum and on the base of machine for the Izod, Charpy test respectively. Changing from one striker to another is achieved simply by fixing the new striker into it’s position. CHARPY TEST The Charpy test piece rests on alloy steel support anvils, fitted on the base of the machine rigidly held in position by Allen screws. End stopper is provided for quickly and accurately locating the test piece centrally between the supports. IZOD TEST The Izod Test piece is clamped vertically in Izod support fitted on the base of the machine. The support is provided with a machined vertical groove to suit the test piece size. The front clamp piece and the Allen screw enable clamping of the test piece in correct height with the help of Izod setting gauge supplied. Optional accessories Self centering tong for quick and accurate setting of Charpy test specimen ‘V’ notch milling cutter. Caliper gauge checking V notch for Izod & Charpy. ‘U’ notch milling cutter. Templates for checking 10x10mm. Cross section of Izod/Charpy test specimen. Depth notch gauge including V & U notch gauges for checking depth below V/U notch, angle and radius. Standard Accessories Izod Striker Charpy Striker Anvil Spanner Set Manual
Pendulum Impact Testing Machine
90,000 Per Piece
5 Piece(s) (MOQ)
We are a trusted organization of this domain in offering a wide gamut of Pendulum Impact Testing Machine to our valued customers. This machine has the large rectangular dial with outer scale for Charpy test and inner scale for Izod. Also, in this, the pendulum is supported separately in two positions by a common latching tune like the upper position for Charpy test and the lower for the Izod test.
Best Deals from Pendulum Impact Testing Machine
Pendulum Impact Testing Machine
90,000 - 400,000 Per
1 Set(s) (MOQ)
We are manufacturing as well as supplying Impact Testing Machine in India. Our Impact Testing Machine is designed for conducting Izod & Charpy test. The test method conforms to BS: 131: part 4 1972 (Amended 15 Aug – 1993) & BSEN: 10045 – 2: 1993.Constriction and functions of Impact Testing MachineThe Pendulum is mounted on antifriction bearings. It has two starting positions, the upper one for Charpy and the lower one for Izod testing. On release, the pendulum swing down to break the specimen and the energy absorbed in doing so is measured as the difference between the height of drop before rupture & height of raise after rupture of the test specimen and is read form the maximum pointer on the dial scale.Controls of PendulumThe Pendulum supported in the starting position is by a self resetting latch. The release mechanism is operated by lever. The pendulum release latch is operated only when this lever is operated. Strikers & SupportsThere are two strikers & one combined support available for fitting into the pendulum & on to the base of the machine for Izod, Charpy test. Changing from one striker to another is achieved simply by fixing the new striker into its position.Optional Accessories Caliper gauge for checking V notch for Izod & Charpy as per BS: 131: Part 1, 2, 3 Depth notch gauge including V & U notch, angle & radius Self centering tong V – Notch milling cutter U – Notch milling cutter Charpy TestThe charpy test piece rests on alloy steel supports anvils. Fitted on the base of the machine rigidly held in position by allen screws. End stopper is provided for quickly & accurately loading the test piece centrally between the supports.Izod TestThe Izod test piece is clamped vertically in Izod support anvils, fitted on the base of the machine. The support is provided with a machined vertical groove to suite the test piece size. The front clamp piece & allen screw enable clamping of the test piece in correct height with the help of Izod setting gauge supplied. NOTE : DUE TO CONSTANT R&D SPECIFICATION AND FEATURES ARE SUBJECT TO CHANGE WITHOUT NOTICE.
Pendulum Impact Testing Machine
Get Price Quote
We are manufacturing as well as supplying Impact Testing Machine in India. Our Impact Testing Machine is designed for conducting Izod & Charpy test. The test method conforms to BS: 131: part 4 1972 (Amended 15 Aug – 1993) & BSEN: 10045 – 2: 1993.Details : Constriction and functions of Impact Testing Machine - The Pendulum is mounted on antifriction bearings. It has two starting positions, the upper one for Charpy and the lower one for Izod testing. On release, the pendulum swing down to break the specimen and the energy absorbed in doing so is measured as the difference between the height of drop before rupture & height of raise after rupture of the test specimen and is read form the maximum pointer on the dial scale. Controls of Pendulum - The Pendulum supported in the starting position is by a self resetting latch. The release mechanism is operated by lever. The pendulum release latch is operated only when this lever is operated. Strikers & Supports - There are two strikers & one combined support available for fitting into the pendulum & on to the base of the machine for Izod, Charpy test. Changing from one striker to another is achieved simply by fixing the new striker into its position. Charpy Test - The charpy test piece rests on alloy steel supports anvils. Fitted on the base of the machine rigidly held in position by allen screws. End stopper is provided for quickly & accurately loading the test piece centrally between the supports. Izod Test - The Izod test piece is clamped vertically in Izod support anvils, fitted on the base of the machine. The support is provided with a machined vertical groove to suite the test piece size. The front clamp piece & allen screw enable clamping of the test piece in correct height with the help of Izod setting gauge supplied. Optional Accessories : Caliper gauge for checking V notch for Izod & Charpy as per BS: 131: Part 1, 2, 3 Depth notch gauge including V & U notch, angle & radius Self centering tong V – Notch milling cutter U – Notch milling cutter
Pendulum Impact Testing Machine
Get Price Quote
The company is a major Manufacturer, Exporter & Supplier of Pendulum Impact Testing Machines. Manufactured as per the BSEN standard, the Pendulum Impact Testing Machines are available in the electronic models and can be customized as well. The Pendulum Impact Testing Machine is known for their remarkable efficiency as well as consistent accuracy. Optional Accessories Caliper gauge for checking V notch for Izod & CharpyTemplates for checking 10 x 10mm. cross section of Izod/ Charpy test specimenDepth notch gauge including V & U notch gauges for checking depth below V/U notch, angle and radiusY Izod support for 0.450" diameter Izod round specimenSelf centering tong for quick and accurate setting of Charpy test specimenV notch milling cutterIT notch milling cutter
Pendulum Impact Testing Machine
150,000 Per Piece
Pendulum Impact Testing Machine
Get Price Quote
The Pendulum is mounted on antifriction bearings. It has two starting positions, the upper one for Charpy & the lower one for Izod testing. On release, the pendulum swings down to brake the specimen and the energy absorbed in doing so is measured as the difference between the height of drop before rupture of the test specimen and is read from the maximum pointer position on the dial scale.