water cooled capacitors
Shreem water cooled Capacitors are especially designed for inductive heat generating plants operating at frequencies as per the furnace design. These capacitors are designed to comply with the specific requirements of each customer. Most of these capacitors provide for step changes in kvar by virtue of terminated sections within each unit. This allows for the tuning of the circuit for changing inductive loads.
...moreThyristor Module
Thyristor modules feature combinations of SCR and Diode configurations in an electrically-isolated base- plate construction that allows for mounting with other components on a common heat-sink without additional clamping or insulation components being required. Thyristor modules are designed for medium and high current power control applications. Featuring electrically isolated package that simplifies system packaging, installation and cooling..
...moreseries reactor
Reduce fault current and Match impedance of parallel feeders Copper Wound Aluminum Wound series reactors have the main advantages that they – Cannot saturate under fault conditions, Have low losses Have a long life Virtually maintenance free
...moreCapacitor Panel
Automatic power factor correction is typical for large electrical systems with fluctuating load where it is common to connect number of capacitors to main power distribution station or substation. The capacitors are controlled by controller which continuously monitors the relative power demand. The relay connects or disconnects the capacitors to compensate for actual reactive power of the total load and reduce overall demand supply. Thyristors are used to switch the capacitors On and Off in the system.
...moreCapacitor Bank
Pole mounted capacitor banks are fixed at 11 KV or 33 KV distributed network feeder. Mounting structure is made in Welded galvanised M.S angle where H.V.Capacitors, capacitor switch, other accessories are mounted on a single pole or specifications received from the customer.
Power : 11 KV or 33 KV
...moreAutomatic Power Factor Panel
Shreem has designed PF controllers by continuous Research and market survey, the products is designed in such a way that it meets the diverse customer needs. We have provided a smartest solution to switch ON and OFF the required KVAR for different type of loads PF controller is available in three different types of series for controlling different type of switching patterns and to control 4 to 16 steps. SPF-series for Single CT contactor switching SPF-T series for single CT thyristor switching SPF3-M series for 3 CT contactor switching SPF3-MT series for 3 CT thyristor switching
...moreAir core reactor
Copper Aluminium wound Air core reactor used to protect the capacitors from High Inrush currents and suppress the harmonics in the system.
...moreBe first to Rate