Fire Survival Cables
Get Price Quote
Designed for Critical Installation of National Importance: • Airports• Metro Rail Projects / Rail Terminals•Nuclear / Thermal Power Plants•Installation Prone to Fire•Interstate Bus Terminals•Introduction Need of ensuring safe operation of critical circuits is essential in today’s installations. Normal cables used in such installations render useless in fire incidences. At Havells, your safety is our concern. Havells has now developed special type “Fire Survival Cables” through research. These cables - also known as CIRCUIT INTEGRITY CABLES & are designed to sustain the high temperatures for a defined minimum period of time under direct fire. These cables are useful to maintain their integrity during the defined period of fire. The construction of these cables is different if compared with ordinary cables. The conductor is manufactured with a specially designed heat barrier and fire resistant insulation which resists the fire to reach conductor surface. The cable continues to remain into operation at high temperatures like 650°C, 750°C and 950°C as per various conditions of operation and applications.Wires offering same properties are also available. These cables are manufactured and tested in accordance with BS 7846, IS 7098(P-1), IEC 69331 and BS 6387 for required temperatures and duration - depending upon the application of cable and site conditions. Constituents HAVELLS FS CABLES are manufactured with the following materials.1. ANNEALED PLAIN COPPER CONDUCTOR2. HEAT BARRIER OVER THE CONDUCTOR3. CROSS LINKED POLYETHYLENE4. GALVANISED STEEL ARMOUR5. ZERO HALOGEN & LOW SMOKE COMPOUND The ZHLS compound ascertains the least smoke and hence increased light transmission during burning of cables. The circuit integrity of HAVELLS FS cables at high temperatures remains unaltered for the required time period as per the specification defined. Test RequirementsHAVELLS CIRCUIT INTEGRITY CABLES are tested in accordance with IEC 60331, IEC 60332-1, IEC 60754-1, ASTMD 2863 & 2843, BS 7846 and BS 6387 for the following properties.1. FIRE RESISTANCE TEST 2. SMOKE DENSITY RATING3. HALOGEN GAS EMISSION TEST4. OXYGEN INDEX TEST5. FLAMMABILITY TEST AS PER SWEDISH CHIMNEY Special PropertiesHAVELLS FS cables are designed with the following special properties which make the cable excellent in the fire conditions.1. Circuit Integrity under fire at high temperature2. Enhanced Current Carrying Capacity due to high permissible conductor temperature 3. Higher Short Circuit Capacity4. Lighter in weight hence easy to handle and installation5. Reluctant to Overheating6. High Oxygen Index – refrains the cable from spreading the fire 7. Low smoke density reduces the environmental opaqueness during fire8. High degree of light transmission in the event of fire9. No chance of emission of Halogen Gases – safe for humans10. Negligible emission of Toxic and Corrosive gases - diminishing the chance to damage the human body/sensitive equipment Circuit Integrity (Fire Resistance) Test : as per IEC 60331 The test is carried out on the cable operational on load and burning at a temperature of 750 Deg C for 3 hours. The cable is put on the clamps above the fire burner of high flames. The power supply is connected to one end of cable at rated voltage and the load is connected to other end. Fire applied for 3 hours and during this period, the circuit integrity must be uninterrupted. After the 3 hours, the fire and power is switched off. The cable should report as usual when energised again after a gap of 12 hours.
heat resistant cables
Get Price Quote
Best Deals from Fire Survival Cable
Fire Resistant Cable
Get Price Quote
The areas for Fire resistant cable applications include places where large number of people congregate for short or limited period of time such as shopping malls, cinema theaters, educational institutions, airport terminals, mass transit systems (metro rail networks), high rise office buildings etc. FR cables also find use in power generation facilities, petrochemical complexes, nuclear power facilities, mines etc. for phased shut down of the plant and to keep critical functions like communication, rescue and evacuation systems functional during a fire.
Fire Survival Cables
Get Price Quote
These are available in Aluminum Copper Conductor and are manufactured as per IS: 63871994 and other international standards.