Brass Double Compression Flameproof Gland
50 - 100 Per Piece
50 Piece (MOQ)
Application Flame Proof Double Compression Glands Are Generally Used In Flammable Gas / Vapors Area (For Gas Group I, IIA & IIB) As Well As In Normal Climatic Conditions Also Which Are Weather Proof, Water Proof And Dust Proof (IP-66) Which Can Be Used In Hazardous Climatic Condition. Also When Protected By PVC Shrouds It Can Be Used In Corrosive Atmosphere. These Glands Are Available In Different Sizes And Are Suitable For All Cables Upto 1000 Sq. Mm. And Control Cables Upto 61 Cores. AccessoriesPVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, Etc. Are Available With Specified Dimensions In Accordance To The Gland Separately.Fitting Sequence Insert Part No. 9, 8 & 7 respectively on the Outer Sheath of the cable before exposing the Armour. After removing Outer Sheath of the cable, Insert Part No. 6 over the Exposed Armour. Size Armour length, Lift Armour & Insert Part No. 5 under the Armour, Taper Part Facing Inward Side, Squeeze Part No. 5 by pushing Part No. 6 towards it. Insert Part No. 4 & 3 on Inner Sheath, than tight Part No. 3 with Part No. 7 & Tight Part No. 9 with Part No. 7. Finally apply the full fitted Gland in the Enclosure with the entry thread provided, if the Enclosure does not have threaded entry than tight the Gland with
DC Flame Proof IIC
Get Price Quote
Application: Flame Proof Double Compression Glands are generally used in hydrogen gas/vapours area (for gas group IIC) as well as in normal climatic conditions also which are weather proof, water proof and dust proof (IP-66) which can be used in Hazardous climatic condition. Also when protected by PVC shrouds it can be used in corrosive atmosphere. These glands are available in different sizes and are suitable for all cables upto 1000 sq. mm. and control cables upto 61 cores. Accessories: PVC Shroud, Earth Tag, Stopping Plug, Reducer, Adaptor, etc. are available with specified dimensions in accordance to the Gland separately. Fitting Sequence: (a) Insert Part No. 10, 9, 8 & 7 respectively on the Outer Sheath of the cable before exposing the Armour. (b) After removing Outer Sheath of the cable, Insert Part No. 6 over the Exposed Armour. (c) Size Armour length, Lift Armour & Insert Part No. 5 under the Armour, Taper Part Facing Inward Side, Squeeze Part No. 5 by pushing Part No. 6 towards it. (d) Insert Part No. 4 & 3 on Inner Sheath, than tight Part No. 3 with Part No. 7 & Tight Part No. 10 with Part No. 7. (e) Finally apply the full fitted Gland in the Enclosure with the entry thread provided, if the Enclosure does not have thread than tight the Gland with the Part No. 1 provided.
Best Deals from Flameproof Cable Gland