Whisper Auto Dialer
CMS - Central Monitoring Station PSTN Auto Dialer features:PSTN based speech dialerMicro-controller based16 key keypad16x2 LCD display1 voice messagesTriggers can be set up as N/O or N/C contacts.Computer Connectivity to do all programming via the computer.10(20 digits) telephone numbers for Intrusion message10(20 digits) telephone numbers for Fire message20 second recording time for each messageDialing to all numbers can be aborted with master code during callSilent dialing for intrusion and fire messages when duress code is entered.Message playbackTelephone number check.Telephone number editing facility.Non-volatile memoryLog Maintenance of 200 events which can be printed via inkjet or thermal printer.Complete memory can be erased at one click in the setup mode.12V - 24V DC variable input voltage3 status LEDs –Power ON, System Active and Playback/Record.On Board 'TEST' button via which user can send a test message and call to any number.Back Light Timing can be configured.(Short-2 Sec,Medium-5 Sec,Long-10 Sec)User can view real Time Log feeds on the Computer and print it via the desktop printer.User can save all the numbers on the computer and later import for new programming of the system. GSM Auto Dialer features:GSM based speech and SMS dialerMicro-controller based16 key keypad16x2 LCD display2 voice messagesTriggers can be set up as N/O or N/C contacts.Computer Connectivity to do all programming via the computer.Separate intrusion messageSeparate fire message10(20 digits) telephone numbers for Intrusion message10(20 digits) telephone numbers for Fire message20 second recording time for each messageAlarm SMS with Alarm type, Time and Date informationSeparate SMS for tamperPower On SMS when system is poweredAll SMS and Calls are optional, and can be configured in Setup.User editable name and address for alarm SMSDialing to all numbers can be aborted with master code during callCall status and network messages displayed.Silent dialing for intrusion and fire messages when duress code is entered.Message playbackTelephone number check.Telephone number editing facility.Non-volatile memoryLog Maintenance of 200 events which can be printed via inkjet or thermal printer.Complete memory can be erased at one click in the setup mode.12V - 24V DC variable input voltage3 status LEDs –Power ON, System Active and Playback/Record.In-built tamper switchGSM signal strength displayOn Board 'TEST' button via which user can send a test message and call to any number.Back Light Timing can be configured.(Short-2 Sec,Medium-5 Sec,Long-10 Sec)User can view real Time Log feeds on the Computer and print it via the desktop printer.User can save all the numbers on the computer and later import for new programming of the system.
...moreTalk Back System
ELECTRICAL SPECIFICATIONOperating Voltage: 12 Volts DcStand By Batteries: 12voltsENVIRONMENT OPERATING LIMITSTemperature: 0 Deg C-50 Deg CHumidity: 90% To 95% RH CondensingCONSTRUCTIONMaterial: 1.6/1.8 mm CRCA Sheet Duly Powder CoatedCable Entry: From Top (Adjustable Knockouts)STATUS DISPLAYZone Status Display: Every Floor Has Separate LedTALK BACK SYSTEMDual Colour Led: Master Phone, 4 Slaves PhonesPOWER SUPPLYMains: 220volt,50 Hz To Internal Main TransformerInput: 15 VoltsOutput: 15 Volts RegulatedCharging Method: 13.8 VoltsDIMENSIONSLength*Breadth*Depth: 17.5"*12.5"*12"Weight: 6 KgSYSTEM STATUS DISPLAYGreen Led: System OnRed LedYellow LedLcd DisplayCERTIFICATIONS
...moreIntegrated Burglar Alarm
KEY FEATURES 18 ZONES SYSTEM (8 ZONES WIRED + 10 ZONES WIRELESS) SYSTEM CONTROL (TRIGGER/ RESET/ SILENT/ ARM/ DISARM) OVER CELLULAR PHONE. SYSTEM CONTROL VIA WIRELESS KEY-FOB AUTOMATIC & MANUAL DAY/ NIGHT CHANGE OVER REMOTE MONITORING VIA LAN CARD OR REMOTE KEYPAD CONFIGUREABLE USER SETTINGS (SOUNDER TIME/ ENTRY-EXIT DELAY/ ZONE SETTINGS) 250 LOG EVENTS ALL WIRED ZONES & SOUNDERS HAVE TAMPER DETECTION FACILITY SPECIFICATIONS GENERALCPU: MicrocontrollerOperating Voltage: 12VStandby Batteries: OnePower Supply: 45 WattMains: 90 - 270V ACInput: 15VOutput: 15 RegulatedCharging Method: Intelligent Trickle ChargingEnd of Lien Resistor: 3.3 K (One Per Zone)USER CONTROLKey Pad: Onboard 6 Key Pad for User Configurable SettingREMOTE MONITORINGSupport Type: Remote Keypad or Lan CardCONSTRUCTIONMaterial: CRC SheetCable Entry: 10 Top KnockoutsENVIRONMENT OPERATING LIMITSTemperature: 0°C - 50°CHumidity: 90% to 95% RH CondensingDISPLAYZone Display: LED & LCDLCD Display: Functional Zone, Signal Strength (GSM1000) System PowerLED'S: Armed, Disarmed, Open, Short, System On, Mains On, Battery On, Zone (1- 8), Battery Cut, Battery Charging, Battery Low, Siren Cut, Motorized Siren Cut, Day, NightDIMENSIONSLength*Breadth*Depth: 325mm*275mm*85mmWeight: 2kgCERTIFICATONSCertifying Body: ERTL (East)INPUTSNo. of Zones: 8 Wired & 10 WirelessDVR Integration: OneInput Type: Normally Open CircuitOUTPUTSSounder Output: TwoInternal Sounders: OneAuto Dialer: InternalAuto Dialer Supported: PSTN/ GSM
...moreintegrated alarm system
KEY FEATURES INTEGRATED ALARM SYSTEM CONSISTING OF 14 ZONE FIRE ALARM SYSTEM WITH 14 ZONE AMPLIFIER. 200 LOG EVENTS STORAGE FOR FIRE EVENTS. VOICE EVACUATION FIRE DRILL FACILITY ONE MAN WALK TEST ADJUSTABLE SOUNDER SETTINGS SPECIFICATIONS SYSTEM COMPONENTSIn-built 14 zone fire alarm(12 volt) In built Public Address (amplifier) for 14 zones. [120 Watt] Menu Settings: Sounder Setting(2-59 mins) Fire Drill Evacuate Log (200 Events) LCD INDICATIONS ON PANELMains onBattery OnBattery LowBattery ChargingZone ConditionsDate and TimeLED INDICATIONS ON PANELSystem On Mains On Battery On Battery Low Battery Charging Zone Indications Fire Normal Open Short Isolate(Zone + Public Address) SPECIAL FEATURESIn case of Fire the Sounder in the particular zone will start ringing for the set sounder time , then the sounder will start ringing in the floor above the affected floor for the set sounder time and then the sounder will start ringing in the floor below the affected floor.The Amplifier will normally be in the OFF state, in case of fire the amplifier will automatically be switched on and the sounders will go in alarm state and will be ready for any announcement.
...moreHand Held Metal Detector
KEY FEATURES FULLY AUTOMATIC SELF ADJUSTING CIRCUITS INBUILT BATTERY CHARGER "VARIABLE AUDIO" GIVES AN IDEA OF QUANTITY OF METAL DETECTION. AUDIO / VISUAL INDICATION FOR METAL DETECTION. HIGH RESISTANT ABS MOULDED BODY. HIGH SENSITIVITY FOR FERROUS, NON-FERROUS METAL & ITS ALLOYS, EVEN CONCEALED IN FERRITE. WILL NOT AFFECT "CARDIAC PACEMAKER & MAGNETIC TAPES / FILM. CMS - Central Monitoring Station FOR WEAPON SEARCHING & ASSET PROTECTIONSecurity Engineers Pvt. Ltd. is the leading manufacturer of Metal Detectors for Security & pilferage prevention application including airports, prisons, customs, banks, police department, courtrooms, public buildings, industry etc. SE-2011 is our new ultra sensitivity detector with a target size down to 0.1gm .SE-2013 Hand Held Metal Detector is light weight, rugged detector for locating hidden metal object on a person."Gives an idea for quantity of metal detection". SPECIFICATIONS DIMENSIONS390 x 50 mm.WEIGHT280 grams approx. (without Battery)OPERATING TEMPERATURE-10°Cto+55°CSENSITIVITY0.1 gm: 30mmRazor Knife (plastic handle) : Dist. 60mmGold Ring 4gm: Dist. 80mmCoin 9.5 gm : Dist. 80mmSEARCH COILCircular 135mm dia.POWER SUPPLYSingle 9V Rech. battery or Dry cell.Continuous operation with 10% alarm time.90 Hrs. On Dry Cell, 20 Hrs on Rech. Battery.RELATIVE HUMIDITY0 to 95% non condensingINPUTSVariable Audio for quantity of metal detection.Visual-> "POWER ON" , METAL DETECTION","LOW BATTERY" & "CHARGE".USEDINDefense services / Police establishments, Factory watch & ward & Security services
...moreDoor Frame Metal Detector
KEY FEATURES MULTI ZONE DETECTION ( EIGHT ZONE) DO OR FRAME METAL DETECTOR IS MICROPROCESSOR BASED & PC COMPATIBLE (OPTIONAL) KEYPAD PROVIDED FOR ALL PROGRAM SETTINGS. AUTO SET (NO INITIAL SETTING IS REQUIRED) DETECTOR IS CONTINUOUSLY ACTIVE SELF TEST PROGRAM , SYSTEM FAULT INDICATOR PROVIDED DISPLAY OF TIME ,COUNTER, PROGRAM SETTING, SENSITIVITY DURING SETTING. MULTI-MODE COUNTER I.E. IN, OUT, TOTAL IN & OUT INFRA RED OCCUPANCY SENSORS. DIGITALLY CONTROLLED SENSITIVITY, & VOLUME. INDEPENDENT SENSITIVITY SETTING OF EACH ZONE. SAFE FOR CARDIAC PACEMAKERS(OPERATING FREQUENCY 10KHZ - 20 KHZ) & FILM SAFE BATTERY BACKUP FOR MEMORY PROTECTION (OPTIONAL). CMS - Central Monitoring Station Security Engineers Pvt. Ltd. SE - VIII are Eight zone separate metal detectors in one frame. This coil structure enhance the metal detection process compared to conventional single zone metal detector. Metal location is reliably displayed at each zone . If metal present in more than one zone all zones with metal are displayed on the geographical Zone Representation provided on the front panel and the zone with the peak metal is displayed on the 8 digit LED display. Sensitivity of each zone can be set separately to get uniform sensitivity at each zone Microprocessor technology ensure fast & reliable data processing & operation. Metal detection, sensitivity setting, Threshold setting, Zone discrimination. SE -VIII detects both ferrous & nonferrous metal. SPECIFICATIONS FLOOR SPACE REQUIRED515 x 895 sq.m (approx)OVERALL FRAME ASSEMBLY515 x 895 x 2130 mm.POWER230 VAC ± 15% 50 Hz, 50 VAPASSAGE CLEARANCE515 x 760 x 1865 mm.WEIGHT60 Kg (approx) Sensitivity Model SE-VIII LOWObjects like GrenadesHIGHSmall Metal Objects of 35 mm side cube of any metalOPTIMUMSmall firearms like 22 caliber gun c)USEDINDefense services / Police establishments, Factory watch & ward & Security services
...moreBe first to Rate
Rate ThisOpening Hours