Scanner DAQ Module
85XX+ Scanner/DAQ Module The 85XX+ is an upgrade on the most successful model 85XX; additional capabilities have been added by way of multi-serial ports, Ethernet port, scanning speed and alphanumeric display. Modular and Expandable 85XX+ is modular in architecture and Expandable, 5 I/O slots can accommodate a mix of Analog Input, Open collector output or Relay output to suit different applications in Power, water and Infrastructure industries. All field inputs are wired by Pre-Fab cables direct into panel terminals. Configuration 85XX+ is configured using the software which is very user friendly; the unit can also be edited by front keyboard and display. The unit has numeric and alpha-numeric displays for value and tag display, Alarm/Trip and control status are displayed by discrete LEDs on front fascia. Communication 85XX+ comes with one RS485 port as a standard, a second RS485 port or a Ethernet Port are options to enhance the communication capabilities of the unit and use it as an RTU, Alarm controller or protection device for motors, transformers, etc Control or Alarm The 8 Relay outputs can be freely mapped to any channel set points and configured as Alarm or Trip functionality with Fail-Safe or Normal Logic. The 24 OC outputs can be used as On/Off control output for individual channel or as a status output for Alarm condition. Features Compact and Rugged Extruded Aluminum Chassis with IP-54 front EMI/EMC Type test qualified CE marked 5 I/Os Slots capacity Max Configuration: 24 AI + 8 Relay + 24 OC Field Scalable 8 channel Universal Analog Input Module 8 Relay output Module 24 open collector outputs Module Fast sampling and generation of Alarm/Trip User free mapping of Relay to Channels Comprehensive alarm/trip logic Alpha-Numeric display for Engineering units 2X RS485 Serial communication ports 1X Ethernet port Modbus RTU over serial and Modnet over ethernet Protocols Windows based mSCAN+ configuration tool
...moreModbus I O Module MAS
8-Channel Modbus I/O Module - MAS-AI-U-8-M Masibus is a low-cost 8-Channel Modbus based remote IO unit in DIN rail mounting, which provides an easy way for integrating analog signals to supervisory SCADA/PLC/DAS systems. There are several inputs which this model accepts as an input like mA, V, RTD, Thermocouple, etc. Modbus IO module measures all field signals with accuracy of 0.1% of FS. Modbus IO module has high speed scanning rate of 125msec/Channel. This module is powered by 24VDC auxiliary supply and power consumption is limited to 3Watt maximum. This module provides isolation between channel to channel and between all input signals and power thus protecting the connected instrument by eliminating ground loop effects. This reduces substantially the undesirable interferences and instabilities in measurements from sensor. Modbus IO can be easily configured, calibrated and diagnosed via the digital interface by using the Windows based Masibus ‘mAIM’ free software. It automatically detects active devices in the Modbus network and permits configuration of all parameters. Modbus IO configuration is done via the RS485 interface by using Modbus-RTU commands. Features: Accepts mA, V, RTD, T/C Programmable 8-Channels, 16-bit resolution 1.5KV Isolation between supply/input/output Dual serial Modbus communication port 24VDC Auxiliary power supply Programming and calibration using software DIN rail mounting Cost effective as Distributed IO
...moreMINT CP Module
The MINT CP is a Communication Processor which connects MINT-IOs and Serial Modbus-RTU Devices to a Modnet Ethernet Network. MINTPLUS configuration Software is available to configure the MINT CP fully with IP address, subnet mask, Modnet parameters and Serial Modbus master parameters. The master device which is polling the IO-modules must be configured with IP address and Modnet Parameters of CP Module. Features: Number of MINT-IOs per Serial port: 15 maximum Ethernet: 10/100Base-T - auto-detecting Connector: RJ45 - auto-crossover Serial RS485 Communication Number of Serial Master ports: 2 (Only one active at a time, Selection through Modnet Register) Protocol supported: Modbus RTU master
...moreMasibus MINT DO Field Interface modules
Masibus MINT DO-16 is a member of MINT IO series which is the most cost effective Field Interface modules for Smart Systems whether it is DAS, SCADA, PLC or DCS. The MINT DO-16 has 16 Open collector outputs. It has two RS485 ports with Multi-drop communication facility. It is powered by 24VDC supply. Using MINT IOs supervisory system can read remote process values and events as well as can communicate for process control. These IOs consists of powerful processors suited for high-speed communication and enhanced hardware features. The MINT series is best suited for plants or processes which require reliable and efficient control with high speed connectivity for system monitoring and information exchange up to the corporate network. Features: 2X Modbus Serial ports Compact DIN Rail enclosure High-Speed Communication Up to 127 Modules on RS485 Network LEDs for Fault, communication and Power 1500V RMS Isolation Configuration & Troubleshooting Software Applications: Cost effective Field Interface to PLC/DCS Remote IOs for Monitoring and Control SCADA Security systems Building automation Gas Detection systems Infrastructure Monitoring Asset Management
...moreMasibus MINT AO
Masibus MINT AO-08 is a member of MINT IO series which is the most cost effective Field Interface modules for Smart Systems whether it is DAS, SCADA, PLC or DCS. The MINT AO-08 has 8 analog output ports with 0/4-20mA or 0-10VDC signal options. It has two RS485 ports with Multi-drop communication facility. It is powered by 24VDC supply. Using MINT IOs supervisory system can read remote process values and events as well as can communicate for process control. These IOs consists of powerful processors suited for high-speed communication and enhanced hardware features. The MINT series is best suited for plants or processes which require reliable and efficient control with high speed connectivity for system monitoring and information exchange up to the corporate network. Features: 2X Modbus Serial ports Compact DIN Rail enclosure High-Speed Communication Up to 127 Modules on RS485 Network LEDs for Fault, communication and Power 1500V RMS Isolation Configuration & Troubleshooting Software Applications: Cost effective Field Interface to PLC/DCS Remote IOs for Monitoring and Control SCADA Security systems Building automation Gas Detection systems Infrastructure Monitoring Asset Management
...moreMasibus MINT AI Field Interface modules
MINT AI-08 Masibus MINT AI-08 is a member of MINT IO series which is the most cost effective Field Interface modules for Smart Systems whether it is DAS, SCADA, PLC or DCS. The MINT AI-08 accepts 8 analog inputs from range of signals like Thermocouples, RTDs, Current, Voltage and Resistor. It has two RS485 ports with Multi-drop communication facility. It is powered by 24VDC supply. Using MINT IOs supervisory system can read remote process values and events as well as can communicate for process control. These IOs consists of powerful processors suited for high-speed communication and enhanced hardware features. The MINT series is best suited for plants or processes which require reliable and efficient control with high speed connectivity for system monitoring and information exchange up to the corporate network. Features: 2X Modbus Serial ports Compact DIN Rail enclosure High-Speed Communication Up to 127 Modules on RS485 Network LEDs for Fault, communication and Power 1500V RMS Isolation Configuration & Troubleshooting Software Applications: Cost effective Field Interface to PLC/DCS Remote IOs for Monitoring and Control SCADA Security systems Building automation Gas Detection systems Infrastructure Monitoring Asset Management
...moreMasibus MINT Field Interface module
Masibus MINT DI-16 is a member of MINT IO series which is the most cost effective Field Interface modules for Smart Systems whether it is DAS, SCADA, PLC or DCS The MINT DI-16 has 16 Digital Inputs with counter to accept 1 KHz input. It has two RS485 ports with Multi-drop communication facility. It is powered by 24VDC supply. Using MINT IOs supervisory system can read remote process values and events as well as can communicate for process control. These IOs consists of powerful processors suited for high-speed communication and enhanced hardware features. The MINT series is best suited for plants or processes which require reliable and efficient control with high speed connectivity for system monitoring and information exchange up to the corporate network.. Features: 2X Modbus Serial ports Compact DIN Rail enclosure High-Speed Communication Up to 127 Modules on RS485 Network LEDs for Fault, communication and Power 1500V RMS Isolation Configuration & Troubleshooting Software Applications: Cost effective Field Interface to PLC/DCS Remote IOs for Monitoring and Control SCADA Security systems Building automation Gas Detection systems Infrastructure Monitoring Asset Management
...moreChannel Scanner DAQ Module
8208 8-Channel Scanner/DAQ Module Compact, Advanced and Fast The 8208 is succeeding the most popular range of 85XX scanners. It offers the host of features in compact 1/4 DIN size for multi-channel process monitoring with advanced functions and simple programming. 8208 has excellent software configurability for 8 channels accepting universal input and 4 relays to serve diverse applications. User has facility to program individual alarm, trip set-points and logic individually or group wise. Channels can be configured up to 4 groups with two relay outputs per group. Two discrete LEDs are provided per channel and one LED per relay for indication. It has built-in RS485 serial communication port. It also has optional retransmission output with high accuracy for communication with PLC/DAS/SCADA. Features Universal Input Universal Power Supply Fast channel scanning Configuration levels with password Configuration and calibration from front keys Isolated RS845 port with Modbus-RTU Full mapping flexibility of four relays and groups Comprehensive Alarm/Trip logic programming User-friendly design Applications Motor protection: Winding & Bearing temperature Air compressor, pump, DG temperature monitoring Drying Ovens Fermentation Processes Flow Monitoring Retorts and Cooking Processes Sintering Furnaces for processing metals and ceramics Heat Treatment: to achieve desired result f hardening or softening material Power Monitoring
...moreChannel Logger DAQ Module
8040 128-Channel Logger/DAQ Module The 8040 is a versatile solution for many data acquisition requirements with 512Kbyte memory for up to 128 channels. From basic data logging to monitoring requirements, communications and software tools make the 8040 more than just a recording device. Enhanced Modularity 8040 is available in two versions, a half 19" rack module and full 19" rack module. It is expandable up to 48 and 96 channels respectively through the use of 8-Channel plug-in modules accepting universal inputs. Parameters of these modules can be monitored, configured and calibrated using local operator terminal or mACplus software remotely. Logging and Communication Data logger enables user to log and monitor process data with time-stamp. Input channel number can be selected for logging and printing for specified time interval from operator terminal keys or using Masibus mACplus software. Print on demand facility is also available. Data logger can also be interfaced with SCADA/PLC using RS485 port. Measurement and Alarm 8040 provides accurate and high-speed measurement with scanning speed of upto 112 channels/Sec. 8-channels DO module provides alarm signal to annunciate abnormal process condition. 4 alarm levels per channel can be configured. Features 16 to 112 channels 512KB non-volatile flash memory Universal input for each channel-mix High noise rejection and isolation Scanning speed: 16 to 112 Channels per second Two RS485 ports One Centronics printer port Operator terminal with 2x16 LCD Programming via Operator terminal or PC
...moreBe first to Rate
Rate ThisOpening Hours