Horizontal Rectangular Autoclave Dealers in Mohali

(2 products available)
  • Rectangular Horizontal Autoclave (GTA-004)

    Rectangular Horizontal Autoclave (GTA-004)

    Get Price Quote

    • Brand Name: Genist
    • Application: Laboratory
    • Material: Mild Steel
    • Product Name: Horizontal Autoclave
    • Approval Certificate: GMP, CE, ISO, IEC Certificate

    Horizontal autoclave is triple walled. Inner Chamber is made of SS 316.  All other chambers, boiler, lid and radial arms made of SS 304. Robust and weld all argon welded construction.  The door is have self-locking safety system Pressure is controlled from 1.2 to 1.5 Kg./cm2.  Provided with multiport valve for easy operation. Supplied with complete IQ, OQ& PQ documentation. Leak proof construction with 316 & 304 stainless steel Sterilizers will have single/double door Hydraulically tested to withstand 2.5 times the working pressure Fitted with water gauge glass for water level All units are hydraulically tested up to 2.5 times of required Triple walled with Steam Jacket and Separate Boiler To work on 440 volts 3 Phase A.C. Supply Meet the NABL standards Low maintenance & Easy operation Pressure Door Lock High grade ring & Door Complete IQ / OQ / PQ DQ Documentation

    more..
  • Horizontal Rectangular Autoclave

    Horizontal Rectangular Autoclave

    1,200,000 Per Piece

    1 Piece (MOQ)

    • Capacity: Up To 3000 Liters
    • Model No.: GTA-004 A
    • Brand: Genist Technocracy
    • Shape: Rectangular
    • Temperature: 121 to 134 – Deg
    • Insulation Wall: Triple wall
    • Available Sizes: 600 X 600 MM to 1200 MM (Customized Sizes are available)
    • Approval Certificate: GMP, CE, ISO, IEC Certificate

    Material : Stainless steel and suitable for materials like Fermentation media, Buffers, reagents, glassware, plastic wares, and autoclavable Bioreactor.   Door Door is fabricated from 304 Maximum operator safety. Process-lock to prevent the opening of the door during the process. Process-lock to prevent the opening of the door after successful completion of the cycle.   Insulation The sterilization chamber is insulated with a minimum of 50 mm thick R. B Glass Wool, which is held in place by an outer cover of SS 304. A 0.3- micron vacuum break. Air filter provided on the sterile side for pressure equalization after vacuum creation.   Piping Package All proess piping in contact with the chamber is fabricated from SS 304 with argon welding. All connections and fittings used are sanitary tri-clamp with silicone seals. All non-contact piping is fabricated from SS 304 with argon welding. All drain lines and exhausts are connected to a drain manifold. The pipelines should have a 2 % slope for full draining to prevent contamination. All pneumatic lines shall be polyurethane with aluminum die-cast connectors.   Valve Package The process valves in contact with the chamber should be SS 304 contact parts with Teflon seat and tri-clamp connections. All automatic valves are to be pneumatically actuated angle valves. The valves are to be actuated by instrument air controlled via solenoid valves.   Steam Accessories The jacket and chamber are provided with an over-pressure safety valve. The chamber is provided with a steam trap. The inside of the chamber and doors are to be finished to a surface finish better than the 0.8 Ra value. All other noncontact parts are to be polished to a surface finish better than 180 grit.   Process Management System The sterilizer is designed to perform a wide range of tests and production programs to meet the latest regulatory requirements.   Temperature and Pressure Sensors Two sensors are provided, one inside the chamber and one at the drain outlet. For accurate process control and recording, all sensors are connected to the PLC and Recorder. The system must have a least count of 0.10 C. A pressure transmitter to be connected to the chamber. The system should have a pressure least count of 0.002 bars. All utility lines are provided with a pressure switch for generating an alarm in case of utility failure.   Electrical Switchgear The control cabinet is provided with a main isolator for the three-phase supply and a separate switch for the control supply. The fascia of the control panel is provided with indication LEDs and switches for operation.   Process Recording All the switchgear: – Schneider do matrix data printer for recording, date, time, process parameters, process status, etc., shall be provided alarms with the machine.   Control Panel The system is provided with a user-friendly HMI as a front-end user interface. Following minimum attributes shall be provided. RS 232 port for data communication. In-built Real-Time Clock with date and time function.   Safety The process management system shall be provided with a series of safety and alarm features are as follows: Cycle over. Too long time to create a vacuum. Pressure Achieve. Utility Failure Alarm. No sharp corners should be present. No wielding edges. Low water level. Jacket pressure over. Chamber pressure over.

    more..
  • Best Deals from Horizontal Rectangular Autoclave

Filter by Locality