Gas Release Conventional Fire Alarm Panel
Get Price Quote
Functions : After fire in both the zones following operation takes place in sequence, the timer starts. The delay can be set from 0 to 250 sec with the help of dip switch. The Panels Timer LED On and potential Free Timer Relay operates. After the delay is over, relay of solenoid valve operates, 24 V DC output for Solenoid valve and potential Free Gas Release relay also operates.Abort : After cross zoning the time delay starts and for some reason we do not want to release gas, then short the terminals of ABORT and timer stops. Abort LED on the Panel will glow. Once we release Abort switch then again Timer starts and after set delay, relay of solenoid valve operates.Manual Release : The Manual release can be achieved by shorting manual release terminals and with set time delay, relay of solenoid valve operates.Features of Products : Operates on 230V supply with battery backup with built in charging. Low battery visual warning with audible tone. LED indication for Timer On, Abort and Gas Release. Relay output for actuators. Zone disable facility. Solenoid Output with time delay. Made from M.S. CRCA rugged with powder coated finish.
GSM Hybrid Alarm Panel
Get Price Quote
The GSM Hybrid Alarm Panel provided by us efficiently communicates with an extensive range of wired and wireless devices including life protection devices to alarm users before any potential accidents. We only source the products that comply with international quality standards. To get reasonably-priced GSM Hybrid Alarm Panels in timely manner, global buyers can contact us. We are the GSM Hybrid Alarm Panels’ Exporter and Supplier from Mumbai, India. Features : Hybrid alarm panel – 16 wireless & 4 wired zone Built in GSM/GPRS modem for cellular alert You can use your phone as a remote controller Auto dialer – 5 groups – 20 phone numbers maximum SMS – 3 groups – 11 mobile numbers maximum Built-in MIC for audio monitoring & speaker for announcement Dual alarm output 1st for low alarm auto mode & 2nd for high alarm manual activation Voice alert message with location name during panic One stop solution – can be used as an Intrusion, Fire & Medical alarm system Optional integration of 21series DVR & alarm panel enables alarm center function so that you can see before you act Maximum 48 wireless + 4 wired detectors per panel Support rechargeable battery for power backup LED status indicator Built in siren Up to 30minutes delay time for arming Tamper alarm and low battery prompt
Best Deals from Alarm Panels
Multi protocol Fire Alarm Control Panel
Get Price Quote
We are offering multi protocol fire alarm control panel. the zx1e is an intelligent fire alarm control panel. It has been designed and constructed around proven and reliable microprocessor technology. This simple approach has produced a modular, scaleable fire alarm platform suitable for protecting all types of premises. The zx1e control panel supports a total of five industry leading protocols, allowing fire detection devices to be independently selected based on performance or aesthetic appeal. The zx series control panels seamlessly integrates with apollo (xplorer, xp95 & discovery), hochiki esp, nittan, morley-ias and system sensor detection device protocols. Designed for maximum flexibility the zx1e control panel is supported by a complete suite of peripherals and software tools. Information on the location of fires, faults and system status can easily be displayed or printed in multiple locations. Integration to voice evacuation systems, paging systems and third party control systems is supported through a range of peripheral interface units. features: multi protocol modular concept simple, robust design intuitive to use easy to maintain easy to expand easy to network easy to install easy to configure
conventional fire alarm panel
10,000 Per Piece
1 Piece(s) (MOQ)
Features of Control Panel : In-built software to sense, receive and recognize the signals sent by the sensors During any abnormal condition or malfunction, an alarm is activated that has to be acknowledged physically and reset Available in 2 to 8 zone (areas) options SMPS power supply Software provided for monitoring and report generation and events logging LED's for individual ZONES to indicate status of respective zones Relay outputs provided for individual Zones Relay output activates in Short / Alarm condition of respective zone Relay output for hooter gets activated, when Short / Alarm condition occurs in any sensors Mute switch provided for silencing the hooter Limit switch for sensing door status (i.e. Open / Close) provided A Buzzer which beeps with hooter in Short / Alarm and Open Panel Door conditions is provided. Here, the buzzer cannot be silenced through Mute key Communication : RS485 serial port at eight baud-rate speed setting (Default 9600 bps) for interfacing with Master (PLC, PC) Optional Potential free outputs for all zones Modbus RTU interface to communicate with BMS System Display : 4x20 LCD for displaying status of all Zones LED Display status for all zones ConvertorRS 485 to RS 232 convertor available at extra costModelsAvailable in 2 Zone to 8 Zone options
Fire Alarm Panel
Get Price Quote
2 Loop Fire Control System
Get Price Quote
Fret not! We are here to help you out with the payment procedures. Be it online or offline payment method, we are here to assist you all the way through the payment process. We have a capacious warehouse facility that assists us completely in making stock and furnishing varied requirements of the clients. Also, our facility is equipped with modern storage amenities.Standard Features : UL 864 9th Edition listed Multi-Loop 2 Analog Addressable Loops Field upgradable to 4 126 primary points per loop Powerful, network wide cause and effects (500 total). Fully user programmable by point or zone. 800 points per panel when using devices with subpoints Up to 10,000 ft. wiring length on SLC loop 64 Panels on a network Programmable through a PC connection to the panel, or through keypad Programmable relays – 5 Supervised Powered Outputs – 3 Programmable Notification Appliance Circuits - 4 Power per NAC - 1.6 Amps Max Programmable outputs on SLC loop Programmable Function button on front display Fire Drill button on front display Day and night sensitivity settings (user programmable) Power Supply - 5.25 Amp, regulated & integrated LCD Display - 8x40 Zonal Mode - Annunciation by zone w/o individual relationships Panel Ring Modes - Common, Zonal, Stage 2 NAC Outputs programmable as Continuous, March, Temporal Program Cause and Effects AND, OR, or Any Two (Cross Zone) Battery size - Up to 17 Ah in standard enclosure; up to 52 Ah with external cabinet Access levels - 3 Access key switch - Yes Recognized for use in High Rise One man walk test – Fire Test Mode Available with semi flush trim ring Available in Red or Gray Product Overview : The VF1460 and VF1480 analog addressable FACP supports 2 or 4 SLC loops for a total of 500 primary points or 800 points using subpoints. SLC loop communications uses standard twisted pair cabling, shielded cable is not necessary. The panel may be configured with various communication cards; Communications options support central station monitoring, Virtual Panel, and networking. The Panel can be configured as a stand alone panel with just a few devices for a small building, it can also operate as the building system and can be part of a network with a total of 64 nodes serving a multiple building campus or a very large facility. Auto Learn capability provides a convenient method to troubleshoot new installations before final programming is loaded. Added Features : Elite with eNET (VF1465/VF1485) Network uses standard RS485 cabling Up to 2,000 ft. between adjacent panels 115 Kbps constant network speed Secure, fault tolerant communication Up to 64 nodes Elite with DACT (VF1464/VF1484) Dual line digital communicator and modem Contact ID and SIA reporting UL 864 9th edition listed Zone or point reporting Backup and duplicate reporting
Fire Alarm Control Panel
Get Price Quote
We are the leading Manufacturer and Supplier of efficient Fire Alarm Control Panel. The Fire Alarm Control Panel is the Central Monitoring Station where all signals are received and transmitted. It is important that the person responsible for taking action, should know exactly where and what the problem is, as soon as he receives a signal from the panel, given below are the details of how to interpret the various lights and switches on the panel fascia.
12 To 128 Zones Fire Alarm Control Panel
Get Price Quote
Fire Alarm Control Panel
Get Price Quote
We have parted our infrastructure into several units and one of them is warehouse wherein we keep a huge stock for furnishing urgent and quick requirements of the clients. We have hired only professional packaging personnel who have experience and expertise in this domain. They make use of the finest quality packing material to ensure zero damage during transit.
Fire Alarm Control Panel
Get Price Quote
The Fire•Lite MS-25(E) is a Fire Alarm Control Panel (FACP) and Digital Alarm Communicator/Transmitter (DACT) combined into one circuit board. With an extensive list of powerful features, the MS-25 fits into applications previously served only by conventional panels. This compact, intelligent addressable control panel supports up to 25 Honeywell Fire Systems addressable devices of any type of detectors and modules. With code wheel addressable detectors/modules and JumpStart® feature the MS-25 can be Life Safety operational without a single programming tool. Powerful features such as drift compensation and maintenance alert are delivered in this powerful FACP from Fire-Lite. The MS-25's integral DACT transmits system status (alarms, troubles, AC loss, etc.) to a Central Station via the public switched telephone network. The power supply and all electronics are contained on a single circuit board and housed in a metal cabinet. Custom programming can be performed through FACP built-in browser (no programming software required) with a PC. NOTE: Unless otherwise specified, the term MS-25 is used in this data sheet to refer to the MS-25 and the MS-25E. For details on the Canadian version, see DN-60641.  features • Two independently programmable output circuits. Circuits can be configured for the following outputs: – Style Y (Class B). – Door Holder Service (cannot be used for notification appliances). – Aux Power Source (cannot be used for notification appliances). • Silence Inhibit and Auto-silence timer options. • Continuous or Temporal code. • Selectable strobe synchronization per NAC. • Up to 2.0 A total output power, 1.0 A for auxiliary power and door holder. Each circuit can source up to the total system current 2.0 A.  specification • ETL listed to ANSI/UL 864 9th Edition Standard • Listed to UL Standard 864, Ninth edition. • JumpStart® auto-learn feature reduces installation time and makes programming easy. • Built-in digital communicator. • Two programmable Style Y (Class B) notification appliance circuits (NACs). • Selectable strobe synchronization for System Sensor®, Gentex®, Wheelock® or AMSECO devices. • Two programmable Form-C relays and one Form-C trouble relay. • Automatic detector sensitivity testing (NFPA 72 compliant). • Point status eliminates calibrated smoke test requirements for NFPA 72. • Drift compensation. • Alarm verification per zone of detectors. • Walk-test. • Honeywell Fire Systems detectors and modules are codewheel addressed for faster installation time. • Maintenance alert region. • Uses standard wire (unshielded or twisted pair). • Central Station reporting up to five zones. • On Board Annunciator.
Addressable Fire Detection Alarm Panel
Get Price Quote
 Addressable Fire Detection Alarm Panel Specification Ravel Indian Manufacturer, International standard. Switch Mode Power Supply. Modular Construction, Serviceable. Surface Mount Technology. Battery polarity & deep discharge protection. As per IS -15908: 2011 Standard. 16 X 2 Dot Matrix LCD Display. Standby battery backup with built in charging. Fire / Fault status in unambiguous colored LED indication. Switch Mode Power Supply. Tactile Keypad for easy panel operation. System on indication. Main, Standby status indication. Low Battery visual warning with audible tone. Relay output for actuators for Fire and Fault. Lamp Test facility Zone wise one man walk Test Facility. Zone wise Isolation facility with loop voltage cut off. Compatible to all type of Conventional Detectors. Optional Zone Wise Sounder / Zone Wise Contact.
Fire Alarm Control Panel
3,500 Per Piece
Fire Alarm Panel
Get Price Quote
Features Rugged CRCA sheet with powder coated finish. Modular Construction. Operates on 230 VAC, 24 VDC. Standby Battery backup with build-in charging. Fire Fault status in unambiguous colored LED. System On, Main, Standby ON status indication. Low Battery visual warning with audible buzzer tone. Earth fault indication with audible buzzer tone. Relay Outputs for actuators. Lamp test facility. One man walk test facility. Zone Isolation facility with loop voltage cut off. Compatible to all types of conventional detectors.
Fire Alarm Control Panel
Get Price Quote
Fire Alarm Panel
Get Price Quote
Cease Fire XT are Supply & Wholesale expertise in domain, offering wide assortment of Fire Alarm Control Panels. These products are suitable for various industries and known for rendering trouble free operations. The offered products are suitable for various applications to meet client's requirements.
Fire Alarm Panel
Get Price Quote
A Fire Alarm Control Panel (FACP), Fire Alarm Control Unit (FACU), or simply Fire alarm panel is the controlling component of a Fire alarm system.
Intruder Alarm Panel
Get Price Quote
Fire Alarm Control Panel
35,500 Per Piece
1 Piece (MOQ)
Fire Alarm Control Panel
25,000 Per Piece
1 Piece (MOQ)
Fire Alarm Control Panel
Get Price Quote
Addressable Fire Alarm Control Panel
Get Price Quote
Features Each loop can connect up to 250 addressable devices. Maximum networking are 32 loops and total addressable points are 8000. Large LCD screen (40 x 15 lines) allows more events to be displayed on the same screen. Loop device can be set up to be temporarily isolated. Individual loop module test feature to save time on panel test. On-board Self-test feature for simulating alarm output. Easy system programming through PC to panel. Events log can store up to 2030 events. Specification optional thermal printer that can printout complete panel status.
Fire Alarm Control Panels
Get Price Quote
The range of Conventional Fire Alarm Control Panels is ideal for Banks, Small Offices, Residential buildings and Warehouses. The indication of fire is zone wise. Audio notification is provided by hooters, PA system and voice annunciation procedures. Special RS-485 based repeaters and mimic panels are available for alphanumeric annunciation of zone names.
Fire Alarm Control Panel
Get Price Quote
cctv amc services, fire alarm installation services, Fire Alarm Cable
Ravel Single Loop Monitor Fire Alarm Addressable Panel
15,000 - 40,000 Per Units
Ravel Single Loop Monitor Fire Alarm Addressable Panel
Fire Alarm Panel
Get Price Quote
Access Control System, CCTV Camera, DVR System, Electronic Security System
navigation light alarm panel
Get Price Quote
navigation light alarm panel, dc power rectifier supply, main switch board
VES eLITE Fire Alarm Main Control Panel, VF 1480
Get Price Quote
VES eLITE Fire Alarm Main Control Panel, VF 1480
Alarm Panel
Get Price Quote
Alarm Panel
Fire Alarm Panel
Get Price Quote
CCTV Camera, fire alarm detector
2 Zone Conventional Fire Alarm Panel, Make- Agni
Get Price Quote
2 Zone Conventional Fire Alarm Panel, Make- Agni