Auto Recloser Dealers in Mumbai

(4 products available)
  • Auto Recloser

    Auto Recloser

    Get Price Quote

    • Weight: 100kg, 109kg, 140kg
    • Rated Maximum Voltage: 15.5kv, 27kv, 38kv

    Autoreclosers can be installed in branch feeder lines in a power distribution system or in a Ring Feeder arrangement for a simple Distribution Automation system. It has been observed that about 70% of faults in a power distribution system are Transient Faults typically less than 100 milli-seconds. With an Autorecloser capable of providing up to 4 reclosing operations each operation user configurable the Autorecloser can monitor the state of the fault on every close. If the fault has been transient then supply is restored. In the case of a permanent fault the Recloser will lockout and isolate the fault. This increases reliability of supply. For the Ring Feeder arrangement they can be set to isolate the faulty section and restore supply to the maximum number of users.

    more..
  • Automatic Recloser

    Automatic Recloser

    Get Price Quote

    • Feature: Rated voltages: 15kV, 27kV and 38kV Rated short-circuit current up to 16kA Etc.

    The N-Series three phase pole mounted auto recloser or circuit breaker was developed to achieve optimum performance and reliability, making use of the latest technology in vacuum interrupters housed in an SF6 gas filled tank. With integrated CT’s and VT’s, the design is optimised for automation, remote control, data logging and monitoring applications. A clearly visible, directly connected pointer provides visual indication of the recloser’s position.

    more..
  • Best Deals from Auto Recloser

  • Automatic Recloser

    Automatic Recloser

    Get Price Quote

    Autoreclosers can be installed in branch feeder lines in a power distribution system or in a Ring Feeder arrangement for a simple Distribution Automation system. It has been observed that about 70% of faults in a power distribution system are Transient Faults typically less than 100 milli-seconds. With an Autorecloser capable of providing up to 4 reclosing operations each operation user configurable the Autorecloser can monitor the state of the fault on every close. If the fault has been transient then supply is restored. In the case of a permanent fault the Recloser will lockout and isolate the fault. This increases reliability of supply. For the Ring Feeder arrangement they can be set to isolate the faulty section and restore supply to the maximum number of users.

    more..
  • 1236kv Pole Mounted Automatic Circuit Recloser

    Get Price Quote

    1236kv Pole Mounted Automatic Circuit Recloser

    more..
Filter by Locality
top