Biosafety Cabinet
Get Price Quote
Bio Safety Cabinet is designed to provide personnel, environmental and product protection. Air flow is drawn around the operator into the front grille of the cabinet, which provides personnel protection. In addition, the downward laminar flow of HEPA-filtered air provides product protection by minimizing the chance of cross-contamination along the work surface of the cabinet. Because cabinet air passes through the exhaust HEPA filter, it is contaminant-free (environmental protection). All Class II cabinets are designed for work involving microorganisms assigned to biosafety levels 1, 2 and 3. Class II cabinets provide the microbe-free work environment necessary for cell culture propagation, and also may be used for the formulation of nonvolatile antineoplastic or hemotherapeutic drugs. General Specifications Two Stage filtration EU6 - Intermediate Filter (95% down to 6 micron) EU14 - HEPA Filter - Supply / Exhaust (99.999% down to 0.3 micron) Statically & Dynamically balanced Motor-blower with suspension arrangement to reduce noise level Double walled flushed Glass Side Panels SS 304 work table with perforations at front & back which can be removed occasionally for cleaning purpose 1-piece fully openable sliding toughened glass front door with counterweight arrangement Sealed Fluorescent Lights with Milky White Diffuser Differential Pressure Gauges : 2 Nos. ON/OFF Switches for motor & Lights Clean Down Timer with Operation HOLD indicator Alarm triggers in case front door is raised more than 8” (i.e. safe clear opening during operation) DOP Test Port 5/15 Amp Switch Socket for external equipment SS 304 stands with leveling lugs SS 304 1 ft long elbow duct for exhaust Options and Accessories A wide range of configurations to suit any containment application : Night Mode Operation Filter blocked alarms (audible and visible) Velocity display with alarms (audible and visible) Explosion proof electrics for Flame-proof applications Once through System Front doors with Glove arrangement Transfer hatch for material movement PLC based Control System Safe change Bag in/Bag out arrangement for filters
Biosafety Cabinet
Get Price Quote
1 Piece(s) (MOQ)
Our Bio safety Cabinets are designed to provide both a clean work environment and protection to operators who work with biological hazards. It has vertrical laminar airflow to create a work area free of airborne particles and micro organisms and also to prevent these particles from flowing into the operator. High Efficiency Particulate Air (HEPA) filters are used to provide clean air in the work area as well as to the environment through exhaustive HEPA filter. The air in the cabinet is re-circulated over the work area through the HEPA filter.Biosafety Cabinets are classified into three categories : Class I, Class II, Class III. Class I : For Personnel and environmental protections. The class I Biological Safety Cabinet is an open front negative pressure cabinet. The exhaust air from the cabinet is filtered by a high-efficiency particulate air (HEPA) filter. It provides protection to human beings and the environment. But it doesn't protect the product from contamination because dirty room air constantly enters the cabinet front to flow across the work surface. Class II : For product , personnel and environmental protections. The Class II vertical laminar-flow biological cabinet is an open-front, ventilated cabinet. This cabinet provides a HEPA-filtered re circulated mass airflow within the workspace. The exhaust air from the cabinet is also filtered by HEPA filter. Thus, Class II bio safety cabinet provides protection to product as well as to human beings and environment. While HEPA filters are effective for trapping particulates and infectious agents, it is suitable for the containment of bio hazardous material thereby providing sterile environment for cell culture. Class II cabinet is the most versatile and economical model. There are four types of Class II cabinets Class II Type A1 (formerly designated Type A): It exhausts approximately 30% air back into the laboratory and re circulates the remainder. May have positive pressure contaminated ducts and plenums that are not surrounded by negative pressure plenums. Class II Type A2 (formerly designated Type B3): It exhausts approximately 30% air through a HEPA filter back into the laboratory or to the environment through an external exhaust duct. It has all biologically contaminated ducts and plenums under negative pressure or surrounded by negative pressure ducts and plenums. Class II Type B1 : It exhausts 70% air through a dedicated duct exhausted to the atmosphere after passing through a HEPA filter and re circulates the remainder. It has all contaminated ducts and plenums under negative pressure or surrounded by negative pressure ducts and plenums. Class II Type B2 : (sometimes referred to as "total exhaust"): It exhaust 100% air through an exhaust duct after passing through a HEPA filter and contaminated positive pressure plenums must be surrounded by a vacuum. Class III : The Class III cabinet is a totally enclosed ventilated cabinet of airtight construction. Operations within the Class III cabinet are through attached rubber gloves. When in use, the Class III cabinet maintains negative air pressure. Supply air is drawn into the cabinet through HEPA filter. The cabinet exhaust air is filtered by two HEPA filters installed in series, before it is discharged outside the facility. The exhaust fan for the Class III cabinet is generally separate from the exhaust fans of the facilities ventilation system.
Best Deals from Biosafety Cabinets
Biosafety Cabinet Controller
5,500 Per Piece
Features: Advanced Micro controller based. 128*64 mm Graphic Display Auto Control Of Blower Built in Uv Timer, U.v Hour Meter. Support Auto & Manual Mode. Hepa Filter Life Alarm Dual Led Indication for On/Off Status of Uv, Blower, Light, Socket Built in Real Time Clock User Programmable Timers For U.v & Blower Support U.v Interlocking Password / Password Change Facility to enter menu Easy to installation & user friendly wiring. Soft touch Membrane keypad. Optional Features: Sach Sliding Window Up-Down Control Available Pressure Real Time Event Logging and output to PC Connectivity. Panel Inputs & Outputs: Inputs: 7 No, switches. Outputs : 14 No. and 2 No led indicator per switch.
Class Ii Biosafety Cabinet
Get Price Quote
Biolab biological safety cabinet class ii series is engineered specifically for laboratory operations that require user and product protection. Operates with a negative air pressure for personnel protection and hepa filtered laminar airflow for product protection. Suitable for microbiological and research applications that do not involve radioactive substances and toxic contaminants. Basic specification : type: class ii, type a2 chamber material: cold-rolled steel coated with anti-bacteria powder coating hepa filter: 2 hepa filter efficiency: 99.999% efficiency at 0.3 µm minimum face velocity: 75 linear feet per minute (lfpm)
Biosafety Cabinets
Get Price Quote
Biosafety Cabinet
Get Price Quote
Biosafety Cabinets
Get Price Quote
Lab Care HorizontalVertical Laminar Flow workstations are designed to protect the product within the work area from airborne particulates in the ambient air. The regulated efflux of custom made laminar airflow supplies the work zone with air cleanliness to offer the best product production by a clean bench in the industry. The HorizontalVertical Laminar Flow workstations pushes the air through a HEPA filter and directs the filtered air horizontally over the work surface at a constant speed, toward the operator
Biosafety Cabinet
Get Price Quote
Intex Cabinet
Get Price Quote
Seema Infocom has gained expertise as an Intex Cabinet Exporter and Supplier in Mumbai, Maharashtra. These Intex Cabinets are made out of the best quality materials that impart strength and durability. These Intex Cabinets are compactly designed and offer complete protection. Our Intex Cabinets can be obtained at the market leading prices.
Biosafety Cabinet
Get Price Quote
Biosafety Cabinet
550,000 Per Piece
BIOSAFETY CABINET CLASS
Get Price Quote
Biosafety Cabinet
Get Price Quote
Biosafety Cabinet, Pass Box, Laminar Air Flow, Sampling and Dispensing Booth
Biosafety Cabinets
Get Price Quote
undefined undefined (MOQ)
Biosafety Cabinets, Air Shower Tunnel, Laminar Flow Bench
Biosafety Cabinet
Get Price Quote
Biosafety Cabinet, Dynamic Pass Box
Biosafety Cabinets
Get Price Quote
Biosafety Cabinets, LOS-120T Triple Tier Orbital Shaker