Navigated Street Light Energy Saver Panels
Our Street Light energy saver supersedes all available technology in the Market. Apart from Energy saving, it maintain near unity power factor, Longitude /Latitude based ON /OFF control, load side MCB's for distribution, maintenance mode, RTC clock with battery back up, Remote online data monitoring, alerts, e-mail, trend, short circuit protection, over load protection are the inbuit features.
Type : Energy Saver Panels
Weight : 4-5kg
Color : Available in Many Colors
Voltage : 220V
Output Type : AC Single Phase, AC Three Phase
Frequency : 50hz, 60hz
Feature : Auto Cut, Easy Operate
Warrenty : 2years
Automation Grade : Automatic
...moreSmart Street Light Energy Saver
1 Piece(s) (MOQ)
Smart street light energy saver with navigator (gsm based remote online monitoringcontrolling) our street light energy saver supersedes all existing technology available in market. The traditional streetlight systems use mechanical ballasts that are either fully on or off. When our energy saver connected in series with any of the street light feeder, our energy saver acts like filter . this will convert losses and wastage of energy in energy saving band. Remarkable saving establishes due to energy saving innovative concept like longitude latitude based on off facility, remote online monitoring with gsm based, without software, alert by smse mail, password protected, all electrical graphical pattern, excess demand controller, theft control, different graphical pattern selection, bar chart daily, monthly report etc. Reduced maintenance cost is additional benefit with a savings apart. Life long , near unity power factor and maintenance free is the beauty of our product. Product range ã¢ï¿½ï¿½ 30 ,51,75,105,120,150 kva, 3 phase, 440vac client - ms cidco navi mumbai-aurangabad, ms central railway- mumbai, ms geda , geb airport authority of india - gujarat, ms visakhapatnam steel plant - vizag
Brand Name : BNN POWER
Application : Energy Saving on Outdoor lights
IP Rating : IP 54/65
...moreSmart GSM based Remote online Data Monitoring
1 Piece(s) (MOQ)
Cloud based online data monitoring ( smart gsm based remote data monitoring) bnn power , mumbai is the leading manufacturers of various energy saving techniques. with online data storage facility for industrial , commercial, hospitals and substation applications. We provide a wide range of services including energy audit ,technical support, industry leading power quality training , harmonics analysis and solution provider and a robust , singe multi point wireless electricity navigator without software. A single or multiple locations can be connected by remote online systems. Also various parameters can be accessible through this kind of online monitoring. A gsm based sim card used to collect the data and through cloud it is accessible to internet as like e mail by dedicated user id & password. No serversoftware required. The cost includes yearly charges, no hidden charges. Different reports,e mail alerts,sms alerts,live data,lt or ht data generation etc. Are the benefits. various applications includes ã¢ï¿½ï¿½ ã¢ï¿½â¢ all electrical parameters data monitoring ã¢ï¿½â¢ report generation in excel or pdf format ã¢ï¿½â¢ alert can be set as required ã¢ï¿½â¢ remote monitoring ã¢ï¿½â¢ demand kva alert limits the demand kva in electricity bills ã¢ï¿½â¢ power factor alert avoid penalty in electricity bills ã¢ï¿½â¢ theft control by alerts ã¢ï¿½â¢ smart data monitoring ã¢ï¿½â¢ transformer supply variation data storage ã¢ï¿½â¢ pcc panel electrical parameters data monitoring ã¢ï¿½â¢ can be used as demand controller ã¢ï¿½â¢ can be used to control daily energy consumed ã¢ï¿½â¢ monthly weekly energy(kwh) can be compaired easily ã¢ï¿½â¢ easy installation in series with existing meter in lt. â�⢠easy installation with ct pt with existing set up in ht. â�⢠shift wise data can be collected data to day basis ã¢ï¿½â¢ useful in case harmonics measurement ã¢ï¿½â¢ multiple (6nos.)meters can be connected by wire to one online meter this will be like energy management system without software. â�⢠data accessible to any computerlaptopmobile ã¢ï¿½â¢ benchmarking is easy
Brand Name : BNN POWER
Warranty : 1 year
...moreScott Transformer
2,000 Per Piece
Type : Electronic Transformers
Certification : ISO 9001:2008 Certified
Usage : Control Panels, Industrial Use, Power Grade
Color : Grey
Specialities : Easy To Install
Frequency : 50hz
Operating Mode : Automatic
Tensile Strength : 0-25Mpa
Warrenty : 1year
Production Power : 100-250kw
...morePower Quality Conditioner for LED lamps
1 Piece (MOQ)
Power quality conditioner for led lamps a led power quality conditioner (lpqc) is a solution to all power quality problems for led lamps installations . Since led lamps are expensive and efficient than that of conventional lamps it is necessary to maintain power quality to enhance the life of led lamps . The lpqc protects all led lamp circuit from voltage spikes, transient,oscilatory waves, noise, impulses, distorted sine waves, under voltage, over voltage, over current, supply variation etc. the lpqc increases performance of electronic devicesequipments, in addition protect electrical system free from harmonics currents and current unbalancing. It also improoves power factor being value addition. Digital display meter will indicate harmonics voltage & current harmonics. In short it maintains quality power by eliminating power disturbances due to industrial commercial utilities like variable frequency drives, ups, office machines, computers etc. This is a perfect product for office and commercial applications. Now the trend is changing and all conventional lamps are converted to led lamps, hence there is a significant incentive need to back up the led lamp load with quality power. Led lamps being energy efficient are more sensitive considering voltage variation, current spikes and harmonics leads to frequent failure.
...moreDistribution Panel Lighting Load Energy Saver Panels
Our company is ranked among responsive and responsible Suppliers of Lighting Load Energy saver with Distribution Panel & APFC, engaged in catering to buyers across varied markets. Working from our base in Mumbai(India), our company is a well-established provider in the industry. The offered Distribution Panel Lighting Load Energy Saver is available with a quality warranty of 12 months.
Type : Energy Saver Panels
Weight : 4-5kg
Color : Available in Many Colors
Voltage : 220V
Output Type : AC Single Phase, AC Three Phase
Frequency : 50hz
Feature : Auto Cut, Easy Operate
Warrenty : 2years
...moreLED Power Quality Conditioner
300 Per Piece
Size : 10x16inch, 12x18inch, 7x12inch, 8x14Inch
Material : Aluminum
Application : Industrial Use
Frame : Aluminum
Feature : Best Grade Material, Durable
Warranty : 1year
Filter Grade : Medium Filter
...moreharmonics filters
95,000 - 96,000 Per Piece
Type : Harmonic Filters
Application : Panels, Electricals Use
Color : Green, Grey, Light Green, Sky Blue, White
Condition : New, Used
Automatic Grade : Automatic, Fully Automatic, Semi Automatic
Warranty : 1yr, 2yrs
Phase Type : Double Phase, Single Phase, Triple Phase
...moreHarmonics Filter for UPS LOAD
1 Piece(s) (MOQ)
Harmonics filter for ups load ups either new or old produces harmonics beyond control. If it is amplified by other circuit or capacitor it is difficult to control. 3 rd harmonics filteration is more critical than that of 5 th, 7 th and higher harmonics. Ups internal harmonics filter is designed to take care of higher order harmonics. Our ups harmonics filter is specially designed to suit this application. Even % thd more than 50 % it is more accurately filtered. Robust and maintenance free design is the beauty of it. Ratings - 10 - 200 kva
Brand Name : BNN POWER
Application : UPS Harmonics Filteration
Phase : Single & Three Phase
...moreHarmonics Filter for AC Drive Load
1 Pack(s) (MOQ)
Harmonics filter for ups load ac drives either new or old produces harmonics beyond control. If it is amplified by other circuit or capacitor it is difficult to control. More critical parameters are 5 th, 7 th and higher harmonics. Ac drive series reactor is designed to take care of some harmonics . Rest of the harmonics are more critical to filter. Our harmonics filter is specially designed to suit this application. Even % thd more than 50 % it is more accurately filtered. Robust and maintenance free design is the beauty of it. Ratings - 30 - 300 kw
Brand Name : BNN POWER
Voltage : 415,440 VAC
Warranty : One Year
...morePassive Harmonics Filter
95,300 Per Piece
Type : Harmonic Filters
Application : Electricals Use
Color : Grey
Voltage : AC
Frequency : 50hz
Automatic Grade : Automatic
Warranty : 1yr
...moreEnergy Saver with APFC & Load Distribution Panel
1 Piece(s) (MOQ)
Light energy saver (les) with without apfc & load distribution our light load energy saver established average 10-40 % saving for energy saving concept. Other than lighting, load works on single phase supply can be accommodated in same circuit. Guaranteed saving with money back policy ensure client result oriented energy saving product. Les services offered comprise latest technology based solutions that provides customers with high savings of energy without requirement of changing existing fittings. These energy savers are placed with incoming supply and distribution board with complete load passed through them. This allows for optimum filtration of the load that aids in minimizing of load current as well as provide for high energy savings. Some of its features include service life of lighting device maintained as provided by manufacturer by ensuring no earlier burnout; provide resistance in abrupt change in current that helps avoiding surge to load; assure of lesser breakdowns and longer life of switchgears; built-in ignition control facility for providing added benefit to lamps providing for maintenance free usage; suitable for use in areas like industrial sector, commercial places, buildings, municipal corporations, shopping malls, hospitals. Compact size will accommodate apfc & load distribution feature with energy saver will control demand kva & power factor product range – 50 - 1000 kva, 3 phase, 440vac, 4 wire 30 – 200 kvar apfc 100- 2000a mccbacb with distribution client - ms tata steel ltd.,aarti drugs ltd- tarapur ms mahindra & mahindra ltd.- pune ms gsfc,ms ntc ltd,ms apollo tyres- gujarat ms nestle ltd.,ms arvind mills ltd.- bangalore
Brand Name : BNN POWER
IP Rating : IP 42/54
...moreDemand Side Mixed Load Energy Saver Panels
3,500 Per Piece
Type : Energy Saver Panels
Weight : 4-5kg
Color : Available In Many Colors
Voltage : 220V
Output Type : AC Single Phase, AC Three Phase
Frequency : 50hz
Feature : Easy Operate, Stable Performance
Warrenty : 2years
Automation Grade : Automatic
...moreDemand side Energy saver Motor/Mixed Load
1 Piece(s) (MOQ)
Demand side energy saving system for motor mixed load with energy and maintenance costs continually on the rise, there is a significant incentive need to reduce costs and improve performance for different electrical sources. Our energy savers delivers a required power at all times maintains consumption at the optimum level and ensure that the load is not subjected to overloads that reduce lifespan & affect the output load. Our power saver adjusts the balanced power to the subject load to meet actual demand in real time environment. As a result, power consumption is decreased by 8 to 15% while power uniformity is maintained. In the interest of reducing the losses and to reduce wastage of energy in the distribution system, our energy saver (es) plays a vital role by converting these losses and wastage of energy in to energy saving band. our es connected in series with the load and acts as like filter. So that complete load passes through es. Normally losses are generated at load side and carried towards source side. All losses are converted in terms of current. If load current is filtered and loss current is only circulated in local network some amount of saving can be established. It’s a part of energy efficiency improvement programme. Always input ( transformer side) impedance is high and load side impedance must be low to maintain the ratio. But we are not measuring the load side impedance and it is varying as per load requirement. Our magnetic amplifier designed to maintain low impedance at the load side .by this method load on motors compressors etc. Remains same so that, torque or rpm not been affected. Current produced by circuit is filtered by our es and passed towards the source. normally different loads has got its own characteristics. Also depending on % loading the characteristics are again different. We design our es which will suit to different types of loads e.g the inductive loads like motors, pumps, compressors, ahu, boilers, lighting lo
...moreCENTRALIZED LIGHTING LOAD ENERGY SAVER
Our Centralized Lighting Load energy saver designed to save 10-40 % Energy saving for Gas discharge lamps like Tube Lights, Sodium Vapour Lamps, Mercury Vapour Lamps, Metal Halide Lamps etc. without wiring changes or alterations. The saving is achieved by introduction of our Energy saver in series with Main Light Distribution Board (MLDB). Complete load will be passed through Centralized Lighting load energy saver. Our Energy saver will act like a Filter works on Flux compensation theory leads to remarkable saving.
...moreBnn power Energy Saver
67,000 - 68,000 Per Piece
Type : power Energy Saver
Feature : Auto Cut , Easy Operate , Shocked Proof, Stable Performance
Voltage : 110V, 220V, 280V,380V, 440V
Warrenty : 1 Year, 2 Year
Condition : New,Old
Color : White, Grey, Black
...moreAutomatic Power Factor Control Panel
1,250 Per Piece
Type : Automatic Control Panels
Color : Grey
Voltage : 220V
Automatic Grade : Automatic
Body Material : Mild Steel
Power : 3-6kw
Power Source : Electric
Phase : Double Phase, Single Phase
Warrenty : 2 Years
...moreAPFC Panels
1 Piece(s) (MOQ)
Apfc panel normal, de tuned & tuned in an industrial plant containing power factor correction capacitors, harmonic currents and voltages can be magnified considerably due to the interaction of the capacitors with the service transformer. This is referred to as harmonic resonance or parallel resonance. For a typical plant containing power factor correction capacitors, the resonant frequency (frequency at which amplification occurs) normally falls in the vicinity of the 5th to the 13th harmonic. Because nonlinear loads typically inject currents at the 5th, 7th, 11th and 13th harmonics, a resonant or near-resonant condition will often result if drives and capacitors are installed on the same system, producing the symptoms and problems with blown fuses, damaged capacitors or failures in other portions of the electrical distribution system. it is a common misconception that the problem of applying capacitors in harmonic environments is limited to problems caused for the capacitor itself that the capacitor’s lower impedance at higher frequencies causes a current overload into the capacitor and, therefore, must be removed. However, the capacitorharmonics problem must be viewed from a power system standpoint. Capacitors and transformers can create dangerous resonance conditions when capacitor banks are installed at the service entrance. Under these conditions, harmonics produced by nonlinear devices can be amplified many times. Problematic amplification of harmonics becomes more likely as more kvar is added to a system which contains a significant amount of nonlinear load. Our normal ,de-tuned & tuned panels are well positioned in market all over india in government ,public & private sectors. We manufacture the same with utmost care so that, simultaneously harmonics and power factor go hand in hand. Now in india only tamilnadu state govt. Issue harmonics penalty , other states also apply the harmonics penalty in short time.
Brand Name : BNN POWER
Voltage : 415/440/480/525 VAC
...moreAPFC Panel
80,000 - 81,000 Per Piece
1 Piece(s) (MOQ)
Type : APFC PANEL
Application : Control Panel
Color : Brown, Grey, White
Voltage : 110V, 220V, 380V, 440V
Application : Boiler Control
Power Source : Battery, Electric
Phase : Double Phase, Single Phase, Three Phase
Warranty : 1 Year, 2 Years
Autoamatic Grade : Automatic, Fully Automatic, Manual, Semi Automatic
...moreHarmonics Audit
By considering to days trend of more and more electronics equipment more heat is generated due to waveform distortion. If it is not traced in time fire can catch the entire premises. Smaller loads like upsserverinvertercomputersac drivesled lamps produce harmonics and can be amplified by capacitors. Thus cable burning and transformer heating leads to possibility of fire or accident or excess energy consumption. Therefore it is necessary to carry out harmonics audits. Also if required suitable harmonics filter can be suggested, which can lead to harmonics free environment. Areas to cover - - commercial buildings - it buildings - godowns - banking branches - malls - residential common meters and respective loads includes lift - supply distribution transformers recent increase in fire catching incidents are examples of harmonics areas covered in mumbai - pawan hans limited - ministry of defence canteen stores building,- churchgate - shatabdi hospital - rajawadi hospital - maa hospital etc.
...moreEnergy Auditing Services
Headquartered in Mumbai (Maharashtra, India), our company in instrumental in rendering excellent energy auditing services to the clients at moderate charges. Owing to our vast experience in this domain, we can ensure our clients that the costs of energy can be reduced substantially. By our effective and cost-efficient services, the clients can save energy and achieve maximum reduction in the overall costs of energy. In addition to this, our wide ranges of auditing services are available at reasonable charges.
...moreENERGY AUDIT /POWER QUALITY AUDIT SERVICES
Energy audit power quality audit service by virtue of our past experience and work done in energy saving, energy audit and related field now we are empanelled with bureau of energy efficiency (bee), nodal agency under power ministry govt. Of india as a energy service company (esco). Now we are among 129 companies shortlisted by bee in the year 2015 to enhance their primary goal: the judicious and effective use of energy to maximise profits, minimize costs and enhance competitive position in all the sectors. energy audit is mandatory important considering fire safety and efficient energy usage. Thermal imaging camera in energy audit plays a vital role in protecting your premises from fire due to more electronics equipment’s and related harmonics producing heating in cables , switchgears and transformer. we have a team of experts having experience of more than 5 years in various field of energy audit, energy saving and energy efficiency improvement. Being oem for energy savers, harmonics filter and automatic power factor controllers we can deliver result oriented power energy audit. The same can also be reflected in electricity bills. Esco based audits can also covered by us. Areas covered – • commercial buildings - • industrial sectors • hospitals • malls • government buildings • club house • stadiums • school colleges • government offices • public private sector offices harmonics audit and guaranteed harmonics control is our specialization
...moreENERGY AUDIT /POWER QUALITY AUDIT SERVICES
One Set(s) (MOQ)
Energy audit power quality audit services by virtue of our past experience and work done in energy saving, energy audit and related field now we are empanelled with bureau of energy efficiency (bee), nodal agency under power ministry govt. Of india as a energy service company (esco). Now we are among 129 companies shortlisted by bee in the year 2015 to enhance their primary goal: the judicious and effective use of energy to maximise profits, minimize costs and enhance competitive position in all the sectors. energy audit is mandatory important considering fire safety and efficient energy usage. Thermal imaging camera in energy audit plays a vital role in protecting your premises from fire due to more electronics equipment�s and related harmonics producing heating in cables , switchgears and transformer. we have a team of experts having experience of more than 5 years in various field of energy audit, energy saving and energy efficiency improvement. Being oem for energy savers, harmonics filter and automatic power factor controllers we can deliver result oriented power energy audit. The same can also be reflected in electricity bills. Esco based audits can also covered by us. Areas covered � � commercial buildings - � industrial sectors � hospitals � malls � government buildings � club house � stadiums � school colleges � government offices � public private sector offices harmonics audit and guaranteed harmonics control is our specialization
...moreOpening Hours