Modular Switches
Get Price Quote
ORIS from L&T. That means quality, reliability and dependability are virtually unmatched. In a market cluttered with many switches, ORIS literally stands apart from the rest. For one thing, it actually glows in the dark - meaning that that even in a dark room you will know where the switches are located. Switches :- Over 1.5 lakh switching operations- Long life ISI marked- conforms to IS 3854: 1997 Fire retardant polycarbonate material for safety & durability. Copper conductors- Better conductivity Silver Coated Brass terminals for more strength IP20 – Finger touch proof terminals Spark Shield – No visible spark Night Locator – Easy to locate switches in dark. Range – Switches, Mega Switches, Plain Switches, Indicator switches, Night Locators, Double pole switches & Bell Pushes Fan Regulator :- Step fan regulator – No more humming noise in fan Full rotating knob ensures no breakage of knob. 120 W capacity – Suitable for bigger size fans also Sockets :- Fire retardant polycarbonate material for safety & durability. ISI marked conforms to IS 1293 :2005 Safety shutters - ensures complete safety while use. Silver Coated Brass terminals for more strength Modular Plates and Mounting Boxes :- Honeycomb design grid plate for extra strength Plates available in various configuration to suit requirement. GI wall box –No rusting in boxes No Welding process makes it RoHS compliant
Motorised COS
Get Price Quote
Motorised changeover switch from 125 to 1600 A The SOCOMEC Motorized Changeover Switch is a motor operated 4 Pole changeover switch. It provides safe changeover giving two stable position I & II and help in changeover from one supply source to another remotely. In case of control supply failure, emergency handle arrangement is provided for manual operation of switch in “OFF” position or selecting the supply.
Best Deals from Circuit Breaker
Electric Switch
25 - 50 Per Piece
Power Supply Board
2,000 - 2,200 Per Piece
2 Piece (MOQ)
Earthing Electrodes
Get Price Quote
Ravi Earthing electrode is best quelity @ quelity product , your safti , Ravi make , Ravi Earthing is manufactured company,
Havells Miniature Circuit Breaker
Get Price Quote
Power Supply Board
Get Price Quote
Foot Switch
350 Per
20 Piece (MOQ)
Residual Current Monitor
Get Price Quote
As a well admired provider of Residual Current Monitor, we bring you a huge variety of unrivaled quality. Our team of experts uses only first-class raw materials to ensure that our product matches to the highest quality grades. It is the perfect solution for commercial application in both earthed and also non-earthed systems. The remarkable features like optimum performance and longer service life make it an interesting proposition. Additional InformationUnscheduled downtimes of machines and plants mean a considerable cost factor. By early detection of insulation faults DOLD insulation monitors help to prevent failures of electrical equipment and thus ensure a better operating reliability and plant safety. They are used both in earthed and also non-earthed systems, but differ in their function principle. In earthed systems (TN systems) DOLD residual current monitors detect fault current with the principle of differential-current measurement and are mainly used to avoid cost-intensive downtimes and to prevent the risk of fire which is latent in the case of slowly evolving insulation faults. In non-earthed systems (IT systems), the insulation resistance to earth of the system to be monitored is measured. Such systems are secured by insulation monitors the use of them in IT systems is required by law by the norm “Safety of Machinery” DIN EN 60204-1 or DIN VDE 0100-410. Thanks to deliberately kept simple functionality of DOLD’s insulation monitors customers benefit from a considerable cost advantage combined with the high quality standard accustomed from DOLD. Advantages At a glance: Save space thanks to compact design Cost-effective and easy-to-use by kept simple functionality Flexible by extended application range of our insulation monitors for systems up to 500V AC and 1000 Hz, i.e. also application for 400V three-phase systems Monitor DC systems up to 280V without auxiliary voltage Improve efficiency: avoid unscheduled downtimes and data losses Improve operational reliability and safety: monitor also at standstill, no interruption of operation in the case of single-phase-to-earth fault Better fire safety: detect slowly evolving insulation faults, minimize accidental arcs as frequent fire cause, split and separately monitor systems in fire- and explosion-prone areas Improve workplace safety: no malfunctions of machinery and systems due to earth faults Save time during maintenance and repair: reduce cost by early detection of insulation faults and well-aimed repair. Technology All conductors of the feeder to be protected (apart from the protective conductor) are guided through a current transformer. In a faultless system, the sum of all currents is zero. No voltage is induced in the current transformer. If fault current flows via earth, the current difference will cause a current in the current transformer. This is evaluated by electronics. Applications Differential-current and insulation monitors are used for early detection of insulation faults in applications where unscheduled downtimes of machinery would have serious consequences. They are used in earthed systems for reasons of efficiency and protection against fire and accidents, but they are required by law in non-earthed systems for the same reasons according to DIN VDE 0100-410 and DIN EN 60204-1. Applications include: Wood working industry: fire prevention Chemical industry: prevent the interruption of chemical production processes Automotive: prevent downtime of entire production lines if one partial area fails Food industry: prevent consequential losses, e.g. failure of a cooling plant Medical: prevent the failure of live-saving facilities Data processing: prevent data loss in computer centers, data processing equipment and systems. Moreover, insulation monitors are used to monitor cut off consumers, which are only needed in certain situations, but must then function without problems, flue gas extraction systems in case of a fire, for example.
bypass switches
Get Price Quote
bypass switches, Earth Leakage Circuit Breaker, em fis meters, Mcb
Switchgear Panel
12,000 Per Piece
1 Piece(s) (MOQ)
Electrical Switches
Get Price Quote
single pole mcb
58 Per Piece
Air Circuit Breaker
Get Price Quote
FEATURES: Conforms to IEC 60947 - 2 & 3 Single frame size for full range Icu = Ics = Icw (1sec) = 50 kA offers complete discrimination with the downstream breakers. Suitability for 690V applications Intelligent ET range of trip systems with current & voltage measurements. All 4 pole breakers equipped with adjustable neutral protections High electrical & mechanical maintenance free endurances BENEFITS: Get the performance you need, at a cost-effective investment, with the quality you demand: ACB offers reliable protection in LV distribution networks assuring continuity of service. Single frame size optimizes switchboard dimensions for complete range from 800 to 4000A. ACB will help to optimize installation & maintenance costs. ACB inherits key values - Safe, Reliable, Simple & Affordable. APPLICATIONS: Air Circuit Breakers are ideal for variety of applications & designed for protection & measurement of electrical distribution networks. Buildings Industrial sites Electrical Utilities and distribution Generator protection
Residual Current Circuit Breaker
Get Price Quote
Frequency converters, medical devices and UPS systems are seeing increasing use in industry. Smooth DC residual currents or currents with low residual ripple may occur in the event of faults on these devices. Type A residual current protective devices are unable to detect these smooth DC residual currents. Furthermore, such smooth DC residual currents make Type A devices increasingly insensitive to AC residual currents and pulsating DC residual currents. If a fault occurs, there is therefore no tripping and the desired protective function is no longer assured.Universal current-sensitive residual current protective devices of Type B have an additional transformer, which is supplied with a control signal. It is therefore possible to evaluate the change of the transformer's operating range caused by smooth DC residual currents, thus ensuring the desired protective function. The devices in this series are designed as residual current operated circuit breakers (RCCBs) up to 80 A and as residual current circuit breakers with integral overcurrent protection (RCBOs) for 100 A or 125 A in Characteristics C or D. Betagard Residual Current Circuit Breakers 5SM3• Standards: IS 12640, Part 1:2008/IEC 61008-1:1996• Voltage: 240/415Vac, 50…60Hz• With ISI marking: CM/L No. 7676092• The tripping characteristic is adapted to the increase of leakage currents at higher frequencies in systems with capacitive impedances and results in increased operating safety.
knife switches
Get Price Quote
We are successfully engaged in offering a superior quality range of Knife Switches. Our offered knife switch is manufactured in an efficient manner in accordance with the quality norms. This knife switch is given in numerous specifications & widely demanded in the market due to its durability & quality. Our knife switch is provided as per the requirements of customers. 5 x 10 Knife switch - Given below are the photograph of knife switches upto 10000 Amps, mounted on SMC / Hylem sheets
control switch
200 Per Piece
Electronic thermal overload relay
Get Price Quote
TeSys LR9 - Electronic thermal relays 18 Electronic thermal overload relays, with built-in alarm function from 18.5 to 315 kW. Complete version: can be selected as class 10 or 20, with an alarm function enabling tripping to be anticipated by shedding the load. Settings locked by sealing the transparent flap.
Thermal Overload Relays
Get Price Quote
Thermal overload relays are protection devices required in various motor starter combinations. L&T’s range of contactor is complimented with L&T’s range of thermal overload relays. Our relays are available for various DOL/ Star delta combinations. They have built in sensitive mechanism which protects the motor from overload and single phasing. Features :- Type RTX & MN-suitable for MNX contactors Ratings: RTX Relay 0.23A-41A MN Relay 0.2A-570A Inbuilt single phasing protection Suitable for direct/separate mounting Built-in ‘START’ and ‘OFF / RESET’ push buttons Auto and manual reset modes Ambient temperature compensation: -5 C to +55 C Electrically separate NO contact Conformance to IEC 60947-4-1 and IS/IEC 60947-4-1 Type RTO- suitable for MO contactors Ratings: 0.23A - 110A Phase failure sensitive Visual status indication Sealable transparent cover Auto/manual reset function Ambient temperature compensated Conforms to IEC 60947-4-1 & IS/IEC 60947-4-1
Main Control And Emergency Stop
Get Price Quote
new India Trading Corporation is one of the leading trading house headed by Mr Dhiresh Kamodia and Mr Hitesh Kamodia. We are authorized dealers for manufacturers like Havells, HPL Socomec, Western, Jaipur Maxwell, Genus, Elymer, Polycab and Esco. We supply our wide range to various contractors, panel builders, OEMs, Retail Shops, Architects, Interior Designers and Builders. Our clients are spread in various countries such as India, Bangladesh, Dubai, UAE and Malaysia. Our success story can be reflected in our sales figure of Rs 1 to 5 crore. We are equipped with excellent warehousing facilities which enable us to fulfill the bulk requirements of the clients. Our highly qualified team of procuring agents ensures that they procure the best quality products for our clients from our esteemed vendors.
temperature switches
Get Price Quote
The range of temperature switches includes components for general industrial use as well as specialised switches for demanding applications.
Air Circuit Breaker
Get Price Quote
Rotary Switches
Get Price Quote
Features DC upto 220 Volts AC upto 440 Volts 10 - 16 - 20 - 25 - 32 - 40 - 63 - 125 Amps Control Circuit / Selector Applications Including Ammeter / voltmeter Selection Handles / Locks / Interlocks Indicating Plates Multipoles Multiways Mountings Multipositions
Modular Switches
38 Per Piece
We are the leading supplier of this products.
Thermal Overload Relay
775 Per Piece
Remote Control Switches
1,000 - 4,000 Per Piece
Change Over Switch
Get Price Quote
. It provides saf changeover, source inversion or switching on load between two low voltage power circuits as well as their safety isolation.The pad lockable handle is to be mounted, on the panel door and lockable in ONOFF position. The external front operation ensures that the door is locked in ON position. Bridging Bars mounted on all ratings as standard.
Double Pole Miniature Circuit Breaker
5,665 Per Piece
Modular Switches
175 Per
Air Circuit Breakers
Get Price Quote