HRC Combination Switch Fuse (HRC Fuses)
Get Price Quote
HRC combination switch fuse units and change over switches confirming to IS:13947.3/ IEC :947-3. Indo Asian combination SwitchFuse units quick make and break from 32A-800A TPN / TPNS in Open Execution/in sheet steel enclosure with HRC fuses, Bolted type/Din type /Cylindrical fuses 80ka ISI approved are also in demand by the panel builders and industries.
Power Supply Board
2,000 - 2,200 Per Piece
2 Piece (MOQ)
Best Deals from Circuit Breaker
Switchgears
Get Price Quote
a reliable source and stockists of abb, l&t, siemens, allien bradley electrical switchgear products
Hager MCB
Get Price Quote
MCCB stands for Molded Case Circuit Breaker. It is another type of electrical protection device which is used when load current exceeds the limit of a miniature circuit breaker. The MCCB provides protection against overload, short circuit faults and is also used for switching the circuits. It can be used for higher current rating and fault level even in domestic applications. The wide current ratings and high breaking capacity in MCCB find their use in industrial applications. MCCB can be used for protection of capacitor bank, generator protection and main electric feeder distribution. It offers adequate protection whenever an application requires discrimination, adjustable overload setting or earth fault protection.
Power Supply Board
Get Price Quote
Electrical Switches
Get Price Quote
Switchgear Panel
12,000 Per Piece
1 Piece(s) (MOQ)
Circuit Breaker
80 Per Piece
Foot Switch
350 Per
20 Piece (MOQ)
Copper Lightning Arrester
Get Price Quote
We are offering copper lighting arrester set viz. Copper pipe, 5 spikes, base plate or socket, gola. Size available as per the order.
Residual Current Monitor
Get Price Quote
As a well admired provider of Residual Current Monitor, we bring you a huge variety of unrivaled quality. Our team of experts uses only first-class raw materials to ensure that our product matches to the highest quality grades. It is the perfect solution for commercial application in both earthed and also non-earthed systems. The remarkable features like optimum performance and longer service life make it an interesting proposition. Additional InformationUnscheduled downtimes of machines and plants mean a considerable cost factor. By early detection of insulation faults DOLD insulation monitors help to prevent failures of electrical equipment and thus ensure a better operating reliability and plant safety. They are used both in earthed and also non-earthed systems, but differ in their function principle. In earthed systems (TN systems) DOLD residual current monitors detect fault current with the principle of differential-current measurement and are mainly used to avoid cost-intensive downtimes and to prevent the risk of fire which is latent in the case of slowly evolving insulation faults. In non-earthed systems (IT systems), the insulation resistance to earth of the system to be monitored is measured. Such systems are secured by insulation monitors the use of them in IT systems is required by law by the norm “Safety of Machinery” DIN EN 60204-1 or DIN VDE 0100-410. Thanks to deliberately kept simple functionality of DOLD’s insulation monitors customers benefit from a considerable cost advantage combined with the high quality standard accustomed from DOLD. Advantages At a glance: Save space thanks to compact design Cost-effective and easy-to-use by kept simple functionality Flexible by extended application range of our insulation monitors for systems up to 500V AC and 1000 Hz, i.e. also application for 400V three-phase systems Monitor DC systems up to 280V without auxiliary voltage Improve efficiency: avoid unscheduled downtimes and data losses Improve operational reliability and safety: monitor also at standstill, no interruption of operation in the case of single-phase-to-earth fault Better fire safety: detect slowly evolving insulation faults, minimize accidental arcs as frequent fire cause, split and separately monitor systems in fire- and explosion-prone areas Improve workplace safety: no malfunctions of machinery and systems due to earth faults Save time during maintenance and repair: reduce cost by early detection of insulation faults and well-aimed repair. Technology All conductors of the feeder to be protected (apart from the protective conductor) are guided through a current transformer. In a faultless system, the sum of all currents is zero. No voltage is induced in the current transformer. If fault current flows via earth, the current difference will cause a current in the current transformer. This is evaluated by electronics. Applications Differential-current and insulation monitors are used for early detection of insulation faults in applications where unscheduled downtimes of machinery would have serious consequences. They are used in earthed systems for reasons of efficiency and protection against fire and accidents, but they are required by law in non-earthed systems for the same reasons according to DIN VDE 0100-410 and DIN EN 60204-1. Applications include: Wood working industry: fire prevention Chemical industry: prevent the interruption of chemical production processes Automotive: prevent downtime of entire production lines if one partial area fails Food industry: prevent consequential losses, e.g. failure of a cooling plant Medical: prevent the failure of live-saving facilities Data processing: prevent data loss in computer centers, data processing equipment and systems. Moreover, insulation monitors are used to monitor cut off consumers, which are only needed in certain situations, but must then function without problems, flue gas extraction systems in case of a fire, for example.
Contactor Switchgear
Get Price Quote
100 Piece (MOQ)
Earthing Electrodes
Get Price Quote
Ravi Earthing electrode is best quelity @ quelity product , your safti , Ravi make , Ravi Earthing is manufactured company,
DU MCCBS
Get Price Quote
Range : 16A to 400A,1P/2P/3P/4P Breaking Capacity : 10kA/18kA/25kA/30kA/36kA/50kA Confirms to IEC60947-2,EN60947-2,IS/IEC60947-2 Current Limiting Type MCCB Higher Mechanical & Electrical Life Internal Accessories :- Auxiliary Contact Trip Alarm Contact Auxiliary+Trip Alarm Contact Shunt Release Under Voltage Release
Motor Protection Circuit Breakers
Get Price Quote
L&T’s Supernova series motor protection circuit breaker (MPCB) integrates functions of a MCCB and thermal overload relay into a highly compact single unit. Equipped with a wide range current adjustment dial (with maximum/minimum ratio of 1.4 to 1.6), the MPCB easily adjusts to match the rated current of the motor, for optimum protection. MPCB provides protection against short circuit & overload. Also the compact size of the MPCB, including overload relay functions, enables a smaller installation area with less wiring space, for a reduction in panel size. Features :- Compactness High Breaking Capacity Short circuit protective coordination Reduction in wiring work Ecological design standards Standard accessories for all frames of MPCB Wide range of accessories which suits your requirements IP20 terminal cover prevents accidental contact to electrically charged part Accessories :- Auxiliary contact blocks Alarm contact blocks Auxiliary and alarm contact blocks Short-circuit alarm contact block Shunt trip devices Undervoltage trip devices External operating handles
Electrical Switches
115 Per Piece
1000 Piece (MOQ)
Electrical Switches
Get Price Quote
Switch Fuse Disconnector
Get Price Quote
Disconnectors are ideally suited as main and EMERGENCY-STOP switches. Thanks to their fused design, they additionally provide short-circuit and overload protection. In connection with SITOR semiconductor fuses, they even master high requirements. In contrast to the 3NJ4 in-line fuse switch disconnectors, the devices of the 3NJ6 range are equipped with an integrated switching element with single- or double-break. They are particularly suitable for applications in which many cable outlets for power distribution have to be accommodated in minimum space. The intelligent plug-in connection system facilitates the devices’ easy and comfortable mounting.New compact Sentron 3NP1 series comes with enhanced protection for personnel and plants and a sophisticated connection system. The reach-round and touch protection incorporated as standard in the new Sentron 3NP1 series prevents users from touching current conducting parts when the devices are mounted in a busbar system, even if they need to be accessed on the rear. Switch Disconnector Fuse Unit [SFU]In-Line Switch Disconnectors SENTRON with Fuses 3NJ6 up to 630 ASFU: Sentron 3NJ6• Four Sizes from 160 A to 630 A• LV HRC fuse links in accordance with IEC 60269-1/EN 60269-1 or BS fuse links in accordance with BS 88.• 3 and 4 Pole Version available• Version with Motorized operating mechanism and electronic fuse monitoring• 185 mm Phase Centre Distance of plug in contacts
temperature switches
Get Price Quote
Gas/Vapour Filled Thermal Sysytem• Wider range of measurement from (-) 15 c to (+) 400°c• Direct and Remote Mounting• Robust and Precise Device T-Series Temperature Switches are designed for use in arduous industrial environment. Th gas/vapour illed thermal system in combintaion with diaphragm sealed piston actuator offers stable measurement of temperature. Actuation mechanism ensures precise switching of desired setpoints. Wide options of microswitches are available to handle different electrical ratings.T-series Temperature Switches are available with rigid stem for direct mounting. Adjustable slding compression gland allows easy installation and adjustment of immersion length. Standard applications include Heat Exchangers, Evaporators, Heat Throwings, Pumps, Compressors, Furnace, Blowers, Air Dryers and so on.
Thermal Overload Relay
Get Price Quote
TeSys LR2 k - Thermal relays 0 Thermal overload relay with manual or automatic reset from 0,11 to 16 A and 0,06 to 5,5 kW . Manual and automatic reset. Terminal block for separate mounting. Can be combined with TeS...s in a 45 mm wide space. Connectors: spring terminal, screw clamp.