Switchgears
Get Price Quote
a reliable source and stockists of abb, l&t, siemens, allien bradley electrical switchgear products
Circuit Breaker
80 Per Piece
Best Deals from Circuit Breaker
Contactor Switchgear
Get Price Quote
100 Piece (MOQ)
Electrical Switchgears
Get Price Quote
We are identified as one of the renowned Electric Switchgears Suppliers in the country. Our entire range of Switchgears are procured from the most respected brands that include L&T, Siemens, ABB, C&S, Schneider Electric, Havellâs, Indo-Asian, Standard, Legrand, HPL, T-C, etc. The miniguard range of Electrical Power Switchgears offers complete safety and proven reliability for low-voltage electrical distribution in the building and construction industry. With passage of time, we have grown as a market leader with flourishing product range that comprises of switchgear, starters, fuse units, change over switches, etc. which are technically excellent and unswerving. Our Switchgears are used for various applications in agricultural, industrial, and domestic sectors. Below, we have mentioned our complete product range in detail. Product RangeAir-Circuit BreakersMoulded Case Circuit Breakers (MCCB's)Switch Disconnector Fuse Units, SDs, On-Load Change Over Switches & HRC FusesContactorsBimetal Overload RelaysTimers & Control AccessoriesMotor ProjectionCircuit BreakersMotor StartersDigital Protective RelaysElectronic Metering DevicesCapacitorsCompact Bypass SwitchesElectronic Motor Protection RelayPush ButtonsLimit SwitchMCBâs, ELCBâs & DBâsPlug & SocketsCable Management System
Edge Protector
Get Price Quote
Details Avoids costly damage to products in shipment or in storage. Stabilizes strapped or stretch-wrapped loads. Provides additional support when double-stacking pallets in warehouse. Can be customized according to requirement. Eliminates shifting loads. Easily trims to your own size with saw.
Copper Lightning Arrester
Get Price Quote
We are offering copper lighting arrester set viz. Copper pipe, 5 spikes, base plate or socket, gola. Size available as per the order.
Havells Earth-leakage circuit breaker
Get Price Quote
Electrical Switches
Get Price Quote
Earthing Electrodes
Get Price Quote
Ravi Earthing electrode is best quelity @ quelity product , your safti , Ravi make , Ravi Earthing is manufactured company,
Residual Current Monitor
Get Price Quote
As a well admired provider of Residual Current Monitor, we bring you a huge variety of unrivaled quality. Our team of experts uses only first-class raw materials to ensure that our product matches to the highest quality grades. It is the perfect solution for commercial application in both earthed and also non-earthed systems. The remarkable features like optimum performance and longer service life make it an interesting proposition. Additional InformationUnscheduled downtimes of machines and plants mean a considerable cost factor. By early detection of insulation faults DOLD insulation monitors help to prevent failures of electrical equipment and thus ensure a better operating reliability and plant safety. They are used both in earthed and also non-earthed systems, but differ in their function principle. In earthed systems (TN systems) DOLD residual current monitors detect fault current with the principle of differential-current measurement and are mainly used to avoid cost-intensive downtimes and to prevent the risk of fire which is latent in the case of slowly evolving insulation faults. In non-earthed systems (IT systems), the insulation resistance to earth of the system to be monitored is measured. Such systems are secured by insulation monitors the use of them in IT systems is required by law by the norm “Safety of Machinery” DIN EN 60204-1 or DIN VDE 0100-410. Thanks to deliberately kept simple functionality of DOLD’s insulation monitors customers benefit from a considerable cost advantage combined with the high quality standard accustomed from DOLD. Advantages At a glance: Save space thanks to compact design Cost-effective and easy-to-use by kept simple functionality Flexible by extended application range of our insulation monitors for systems up to 500V AC and 1000 Hz, i.e. also application for 400V three-phase systems Monitor DC systems up to 280V without auxiliary voltage Improve efficiency: avoid unscheduled downtimes and data losses Improve operational reliability and safety: monitor also at standstill, no interruption of operation in the case of single-phase-to-earth fault Better fire safety: detect slowly evolving insulation faults, minimize accidental arcs as frequent fire cause, split and separately monitor systems in fire- and explosion-prone areas Improve workplace safety: no malfunctions of machinery and systems due to earth faults Save time during maintenance and repair: reduce cost by early detection of insulation faults and well-aimed repair. Technology All conductors of the feeder to be protected (apart from the protective conductor) are guided through a current transformer. In a faultless system, the sum of all currents is zero. No voltage is induced in the current transformer. If fault current flows via earth, the current difference will cause a current in the current transformer. This is evaluated by electronics. Applications Differential-current and insulation monitors are used for early detection of insulation faults in applications where unscheduled downtimes of machinery would have serious consequences. They are used in earthed systems for reasons of efficiency and protection against fire and accidents, but they are required by law in non-earthed systems for the same reasons according to DIN VDE 0100-410 and DIN EN 60204-1. Applications include: Wood working industry: fire prevention Chemical industry: prevent the interruption of chemical production processes Automotive: prevent downtime of entire production lines if one partial area fails Food industry: prevent consequential losses, e.g. failure of a cooling plant Medical: prevent the failure of live-saving facilities Data processing: prevent data loss in computer centers, data processing equipment and systems. Moreover, insulation monitors are used to monitor cut off consumers, which are only needed in certain situations, but must then function without problems, flue gas extraction systems in case of a fire, for example.
Foot Switch
350 Per
20 Piece (MOQ)
Thermal Overload Relays
Get Price Quote
Thermal overload relays are protection devices required in various motor starter combinations. L&T’s range of contactor is complimented with L&T’s range of thermal overload relays. Our relays are available for various DOL/ Star delta combinations. They have built in sensitive mechanism which protects the motor from overload and single phasing. Features :- Type RTX & MN-suitable for MNX contactors Ratings: RTX Relay 0.23A-41A MN Relay 0.2A-570A Inbuilt single phasing protection Suitable for direct/separate mounting Built-in ‘START’ and ‘OFF / RESET’ push buttons Auto and manual reset modes Ambient temperature compensation: -5 C to +55 C Electrically separate NO contact Conformance to IEC 60947-4-1 and IS/IEC 60947-4-1 Type RTO- suitable for MO contactors Ratings: 0.23A - 110A Phase failure sensitive Visual status indication Sealable transparent cover Auto/manual reset function Ambient temperature compensated Conforms to IEC 60947-4-1 & IS/IEC 60947-4-1
Residual Circuit Breaker
Get Price Quote
Rotary Switches
Get Price Quote
Features DC upto 220 Volts AC upto 440 Volts 10 - 16 - 20 - 25 - 32 - 40 - 63 - 125 Amps Control Circuit / Selector Applications Including Ammeter / voltmeter Selection Handles / Locks / Interlocks Indicating Plates Multipoles Multiways Mountings Multipositions
Electronic thermal overload relay
Get Price Quote
TeSys LR9 - Electronic thermal relays 18 Electronic thermal overload relays, with built-in alarm function from 18.5 to 315 kW. Complete version: can be selected as class 10 or 20, with an alarm function enabling tripping to be anticipated by shedding the load. Settings locked by sealing the transparent flap.
Electrical Switchgears
Get Price Quote
Features: 10kA short circuit breaking capacity for ‘B’ and ‘C’ curve Low power consumption, thus cost effective & energy saving Suitable for DC application Finger Safe” terminals - IP 20 degree of protection Products include: MCBS From 0.5A to 63A SP,SPN, DP, TP, TPN-FP, ISOLATORS40A TO 125A DP.,TP FP BREAKING CAPACITY
Temperature Switch
Get Price Quote
MPCB SWITCH GEAR
Get Price Quote
FEATURES: Complete protection concentrated in a single product Compact and simple to select Only 45 mm wide and are categorized according to their level of performance and functions: type of control, breaking capacity, motor protection and accessories. APPLICATIONS: Motor control and protection, in accordance with standards IEC 947-2 and IEC 947-4-1 Easily inserted in any configuration by screw or clip-fixing onto mounting rails
Copper Lightning Arrester Spike
420 Per Piece
modular switch
Get Price Quote