Clean Room Light
5,000 Per Piece
Flameproof Cum Clean Room Area Light Fitting Rating-2 X 36W PL-8
Get Price Quote
Best Deals from Clean Room Fittings and Furniture
Biosafety Cabinet
Get Price Quote
1 Piece(s) (MOQ)
Our Bio safety Cabinets are designed to provide both a clean work environment and protection to operators who work with biological hazards. It has vertrical laminar airflow to create a work area free of airborne particles and micro organisms and also to prevent these particles from flowing into the operator. High Efficiency Particulate Air (HEPA) filters are used to provide clean air in the work area as well as to the environment through exhaustive HEPA filter. The air in the cabinet is re-circulated over the work area through the HEPA filter.Biosafety Cabinets are classified into three categories : Class I, Class II, Class III. Class I : For Personnel and environmental protections. The class I Biological Safety Cabinet is an open front negative pressure cabinet. The exhaust air from the cabinet is filtered by a high-efficiency particulate air (HEPA) filter. It provides protection to human beings and the environment. But it doesn't protect the product from contamination because dirty room air constantly enters the cabinet front to flow across the work surface. Class II : For product , personnel and environmental protections. The Class II vertical laminar-flow biological cabinet is an open-front, ventilated cabinet. This cabinet provides a HEPA-filtered re circulated mass airflow within the workspace. The exhaust air from the cabinet is also filtered by HEPA filter. Thus, Class II bio safety cabinet provides protection to product as well as to human beings and environment. While HEPA filters are effective for trapping particulates and infectious agents, it is suitable for the containment of bio hazardous material thereby providing sterile environment for cell culture. Class II cabinet is the most versatile and economical model. There are four types of Class II cabinets Class II Type A1 (formerly designated Type A): It exhausts approximately 30% air back into the laboratory and re circulates the remainder. May have positive pressure contaminated ducts and plenums that are not surrounded by negative pressure plenums. Class II Type A2 (formerly designated Type B3): It exhausts approximately 30% air through a HEPA filter back into the laboratory or to the environment through an external exhaust duct. It has all biologically contaminated ducts and plenums under negative pressure or surrounded by negative pressure ducts and plenums. Class II Type B1 : It exhausts 70% air through a dedicated duct exhausted to the atmosphere after passing through a HEPA filter and re circulates the remainder. It has all contaminated ducts and plenums under negative pressure or surrounded by negative pressure ducts and plenums. Class II Type B2 : (sometimes referred to as "total exhaust"): It exhaust 100% air through an exhaust duct after passing through a HEPA filter and contaminated positive pressure plenums must be surrounded by a vacuum. Class III : The Class III cabinet is a totally enclosed ventilated cabinet of airtight construction. Operations within the Class III cabinet are through attached rubber gloves. When in use, the Class III cabinet maintains negative air pressure. Supply air is drawn into the cabinet through HEPA filter. The cabinet exhaust air is filtered by two HEPA filters installed in series, before it is discharged outside the facility. The exhaust fan for the Class III cabinet is generally separate from the exhaust fans of the facilities ventilation system.
Stainless Steel Garments Storage Cabinet
70,000 - 100,000 Per Piece
Material GradeSS304 BrandNeelkanth Engineering ShapeRectangle Number Of Door Cabinets2 Cabinets MaterialStainless Steel Height5 to 7 Feet