Producer Gas Burner
Low calorific value gaseous fuels mainly Producer Gas Coal Gas BF Gas can be burnt efficiently,All burners are modulating type with high turn down ratio (1 : 5) and suitable for continuous modulation,Can be supplied for combustion air temperatures upto 400 degree C,Separate fan increases firing flexibility like high furnace back pressure or air pre-heating or no reduction in burner output capacity.
...moreOil Pumping & Heating Units
We offer HPU’s for various size burners. Design, engineering and manufacturing is done by us, depending on burner capacity. Purpose of heating and pumping units is as follows: (1) Filtering of Oil. (2) Raising the oil pressure to required pressure for proper atomization of oil. (3) Heating of oil to the required temperature with the help of electric and steam heaters. (4) Keeping the oil at required pressure and temperature in circulation to enable the burner to be fired. Heating and Pumping Units, mainly consists the following: (1) Circulating header at inlet. (2) Duplex oil filter. (3) High pressure oil pump with motor assembly (1 No. working & 1 No. standby). (4) Electric Oil Pre-heater. (5) Steam Oil Pre-heater. (6) Safety Relief Valve (SRV) and inlet pressure regulating valve (IPRV). (7) “Y” type outlet filter
...moreOil cum Gas Burners
Salient Features : Duobloc with unmatched flexibility All standard liquid and gaseous indicated can be burnt efficiently All burners are modulating type with high turn down ratio (1 : 5) and suitable for continuous modulation High efficiency, low maintainance and long service life Can be supplied for combustion air temperatures upto 400 degree C Fully Automatic with excellent safety features Separate fan increases firing flexibility like high furnace back pressure or air pre-heating or no reduction in burner output capacity.
Capacity : 0.51 MKcal/hr to 21 MKcal/hr
Range : (0.60 MW/hr to 24 MW/hr)
Combustion Air : Upto 400 degree C
...moreHot Air Generators
Combustion Concepts supplies “Hot Gas Generators (HAG)” for various heat loads and temperatures. Main types of HAG’s are as follows: Indirect Type: Suitable for low temperature and where no contact with flue gases is permissible with the final product. Direct type: Suitable for high as well as low temperature applications. HAG’s can be supplied for heat loads upto 20 million Kcal per hour and temperatures upto 1200 degree centigrade. Complete design, engineering, manufacturing and after sales service is provided by us. Comments are closed.
...moreGas Trains
Gas Trains for Standard gases (Natural gases / LPG): Proper fuel pressure plays an important role in efficient running of burners. We at Combustion Concepts select the right component for proper safe working of the system with our wide experience. Gas trains are completely assembled with various components and factory tested for proper working. They mainly consist of the following: (1) Main Isolating valve at inlet. (2) Gas filter for filtering. (3) Slam Shut off valve, to protect components provided after the gas regulator from high pressure in case of gas regulator failure. (4) Gas regulator: To provide a constant predetermined pressure at burner inlet. (5) Gas safety relief valve: To release surges in gas pressure at the time of starting the system. (6) Gas pressure switch: To cut off the burner in case of low pressure. (7) Safety and Main Solenoid Valves: Two numbers valves are provided in series as a safety against gas leakage in the system during shutdown period. These valves can be direct operating solenoid valves or butterfly valves with pneumatic actuators depending on the quantity of gas to be handled. (8) Pilot Gas Train: This consists of isolating valve, pilot regulator and solenoid valve for generating pilot flame which will ignite the main flame. (9) Pressure gauges at the inlet, after the regulator and at burner inlet are provided with isolating valves. Low pressure gauges are provided with block and bleed valves. These valves keep low pressure guages isolated most of the time. In addition to the above, valve proving system (VPS) can be provided for safety against gas valve leakage.
...moreBe first to Rate
Rate ThisOpening Hours