Vibration Meter
VIBRATION METER, acceleration, velocity, displacement Acceleration : 200 m/s2. Velocity : 200 mm/s. Displacement : 2.0 mm. Max hold, peak value, data hold. Memory ( Max., Min. ) LCD display with bar graph. 500 point data logger. Zero adjustment, RS232 computer interface. Optional data transmission software, SW-DL2005. Accelerator and hard carrying case are included.
...moreunder voltage relay
SPECIFICATION System: 3Phase 4wire /1 Phase system. System Voltage: 380 to 41 5 VAC II Under Voltage factory set. Burden on supply : < 3VA. Temperature: -20~C to +5S C Humidity :< 95% Rh condensing, Dimension: 89(L)x 17.S(B)x58{H)mm. Mounting : DIN 35mm Rail I 2x M4 screw. Weight :80gms. FEATURES Trip level 75% of supply voltage. Time delay user set from 5 . 15 minutes. LED indication for "Power up" and "Relay on". Consistent reliability with accuracy. OUTPUT RELAY 1 NC contact / 1 NO contact Rated voltage: 250 VAC Switching capacity: 1250 VA (5 A /250 VAG) Fusing: SA fast acting. APPLICATION Control panel Feeder /motor Generator Transformer MODELS UVR-903 L3 3 4 N | L3 3 4 N | 8 NC | COM 6 7 NO UVR-901 4 N | L1 1 | COM 6 7 NO
...moretransducers
NIPPEN Power line Transducers give load independent and isolated DC outputs proportional to input parameters like current, voltage, frequency, power factor, active power, reactive power and dc isolation. Features A C VOLTAGE. FREQUENCY PF ACTIVE POWER REACTIVE POWER D C ISOLATION Features Linear aux. power supply of 230V AC. Conforms to IEC 60688 and IS 12784. Short circuit protected and open circuit proof. High input/output isolation 3kV/ 4kV. DIN RAIL/ Back panel mounting arrangement. Wide choice of outputs and suppressed ranges. Current or voltage output. Single or dual ISOLATION.
...moreToggle Switches
Features 10 - 15 - 35 Amps 1, 2, 3 & 4 Poles = 2 / 3 Positions Stay put / Spring Return Combination Terminal - Screw / Solder / Push-On
...moreStroboscope
New generation Stroboscope. Digital synthesis circuit, high stability and high adjustment resolution. Range : 60 to 32,000 RPM. Adjustment resolution : 0.1 RPM ( 1,000 RPM ), 1 RPM ( 1,000 RPM ) High intensity light. Setting button : digital rotate button, X 2 button, 2 button, + button, - button, easy to adjust the desired RPM.
...moresingle phase stabilizers
Frequent fluctuations or variations of power not only causes financial but manpower loss too! SENTRI SERVO CONTROLLED VOLTAGE STABILIZERS beast these happenings and provides all extra care needed to your valuable equipments. SPECIFICATION Rating : As Specified Input Voltage Range : As Specified (Eg. 170V-270 V) Input Supply Frequency : 45Hz-55Hz Output Voltage: As specified (Eg. 230V/240V + 1%) Voltage Regulation : + 1% Rate of Correction: Usually 25V/ SEC/Phase but depends on rating Efficiency: Better than 97 % Waveform Distortion : Nil Effect of Load Power Factor : Nil Amibient Tempreture : 0-50°C Max. Type : 1 Phase FEATURES Output voltage sensing for voltage correction & for U/V & O/V trip Overvoltage & undervoltage trip by means of contractor / relay's Voltmeter with selector switch to see input & output voltages Short circuit & overload protection by means of MCB/ FUSE MCCB Adjustment : Output voltages adjustment of + 5V/ Phase will be Adjustment : Output voltages adjustment of + 5V/ Phase will be provided by means of potentio meter on front plate. Controls: Auto/Manual incase of auto mode failure you can set output voltage through manual mode.
...moreSMD TEST CLIPS
The test clips used for measuring the SMD components(resistor, capacitor, inductor, diode..) Cable length : appro x 90 cm.
...moreRotary Switches
Features DC upto 220 Volts AC upto 440 Volts 10 - 16 - 20 - 25 - 32 - 40 - 63 - 125 Amps Control Circuit / Selector Applications Including Ammeter / voltmeter Selection Handles / Locks / Interlocks Indicating Plates Multipoles Multiways Mountings Multipositions
...morepump protection relays
These relays are useful for protection of 3-phase AC induction motors against various hazards. With their unique advantages they eliminate use of a thermal/bimetal relay for motor protection. Being current sensing, they are to be selected according to motor rating and are available for practically all ranges of motors. These relays are ideally suitable for Air-conditioning Compressor motor protection, as also for motors in machines, conveyors, cranes/hoists and lifts, and for pumps. FEATURES Fixed/adjustable under/Over trip settings for parameters. Fixed/adjustable trip delays and Power On delays Built-in or external power supply Resetting Auto or Manual Output contacts : 1 CO or 2 CO Choice of enclosures (DIN-Rail, Plug-in) Models with Micro-Controller based design Serial Communication (RS485) port 2 line alpha-numeric LCD display Use of SMD Technology User-friendly LED indications
...moreProximity Switch
Features Optimum tensile strength Easy installation Precise dimensions
...morePressure Transmitter
2 WIRES PRESSURE TRANSMITTER Range : 2, 5, 10, 20, 50, 100, 400 BAR. Output : 4 to 20 mA DC. 4 mA = 0 pressure 20 mA = full scale pressure 2 wires, both for signal and power supply. Precision ceramic type pressure sensor. External zero and span adjustment. Output with socket, easy replacement. Allow high cable load resistance, transmitter can install far away from the controller/incator. Protection for the reverse wires connecting. TR-PS2W can cooperate the " 4-20 mA Controller/Alarm/Indicator " CT-2012, then become a pressure controller and the indicating system. The user can control and monitor the pressure value from far away.
...morePressure Transducer
PRESSURE TRANSDUCER, 0 to DC 100mV 6 models : 2/5/10/20/50/100/400 bar. Zero pressure - 0 DCV, Full scale - 100 mV. Power supply : DC 9V to 30V. 4 wires : 2 wires for power, two wires for signal.
...morePhoto Electric Sensor
Features Fine finish Robust design Easy to fit
...morephase failure relays
These relays are suitable for monitoring incoming 3-phase supply from Mains (Electricity distribution line). Being independent of load, they can be used for any HP/KW rating of load. FEATURES Fixed/adjustable unbalance settings Fixed/adjustable undervoltage/over-voltage settings Fixed/adjustable trip delays Built-in or external power supply Resetting Auto or Manual Output contacts : 1 CO or 2 CO Choice of enclosures (DIN-Rail, Plug-in) Models with Micro-Controller based design Use of SMD Technology User-friendly LED indications PROTECTIONS / FUNCTIONS Phase Failure [Phase Loss/Single Phasing], Phase sequence reversal, Voltage Unbalance, Under Voltage, Over Voltage ORDERING INSTRUCTIONS Product Family Name Model Name System Supply Voltage & Frequency Aux. Supply / Control Supply Voltage
...morepH Meter
0 to 14.00 pH. ATC (auto temperature compensation). Auto calibration for pH 4, pH 7 or pH 10. Meter with pH electrode, all in one. IP-67, water proof. Easy replacement for the pH electrode. Pen type, easy operation carry out. pH 4, pH 7 standard solution are included. DC 1.5V battery (UM-4, AA) x 4, long life. Pen type easy carryout.
...moreMoving Iron & Moving Coil Meters
Moving Iron Instruments are generally used for measuring AC Voltages and Currents. A feature of the moving element is that it is fitted with synthetic sapphire jewels. The movement is light and quick-acting, but extremely robust. An efficient system of fluid damping is employed. The movement is efficiently shielded against the effect of external magnetic fields. Moving Coil Instruments are used for measuring DC values. They can be used too on AC systems , if the input is fed through bridge rectifiers. A Centre magnet system is incorporated in our moving coil instruments which completely shields the movement from the effect of external magnetic fields. The movement is pivoted between synthetic sapphire jewel bearings for frictionless operation. The above meters can be used for higher ranges by using necessary Current and Potential transformers, and external shunts, Accuracy Class: 1 to 1.5% as per ISS 1248/83, we also manufacture.
...moremotor control switches
Features For Directly Switching On Reversing Star-Delta 2-Speed 2-Speed Reversing Inching of MOTORS of 1, 3, 5, 7.5, 10, 12.5 & 15 H.P . & Switching On of Motor of 18, 22, 30, 37 & 45 KW
...moremonitoring relays
These relays are best suitable for monitoring balanced or unbalanced supplies, either of single phase, 3-phase 3-wire or 3-phase 4 wire loads powered by generators, UPS, stabilizers, inverters, or Mains (by Electricity Boards / Utilities); in AMF panels, PCCs, distribution boards and for power monitoring of individual loads / motors / pumps. FEATURES Fixed/adjustable under/Over trip settings for parameters. Fixed/adjustable trip delays and Power On delays Built-in or external power supply Resetting Auto or Manual Output contacts : 1 CO or 2 CO Choice of enclosures (DIN-Rail, Plug-in) Models with Micro-Controller based design 2 line alpha-numeric LCD display (for F3 VSR1/2) Serial Communication (RS232) port (for F3 VSR1/2 models) Use of SMD Technology User—friendly LED indications PROTECTIONS / FUNCTIONS Under/over Voltage Under/Over Current Under/Over Frequency Reverse Power Earth Fault/Ground Fault Earth leakage ORDERING INSTRUCTIONS Product Family Name Model Name System Supply Voltage & Frequency Aux. Supply / Control Supply Voltage Current input (1A or 5A) CBCT Primary & Secondary Current. Inner Diameter. Outer Diameter. Minilec Relay Model Name.
...moreMicro Switches
Features 10 Amps Single pole,2,3 & 4 Poles Terminal - Screw / Solder / Push-On
...moreManometer
Dual & differential input, 200 mbar x 0.1 mbar. Unit : mbar, PSI, Kg/cm2, inch/Hg, mm/Hg, inch/H2O, meter/H2O, Atmosphere. Data hold, Memory (Max., Min.). RS232/USB computer interface. Application : Industrial, laboratory, schools, heating, ventilation, hospital, medical... Size : 180 x 72 x 32 mm.
...moreLcr Meter
Pocket size, 13 mm LCD, Max. 1999. L- 5 ranges, 2 mH to 20 H. C-6 ranges, 2 nF to 200 F. R- 6 ranges, 200 ohm to 20 M ohm. Economical type. Size : 120 x 72 x 37 mm.
...morekaycee rotary switches
KAYCEE Rotary Switches have been engineered and designed especially to meet the requirements of latest concepts in switching technology demanding miniaturization and sophistication in control engineering. These are guaranteed for optimum performance and meet the most arduous industrial applications. Kaycee Rotary Cam Switches are hand-operated, assembled on packet principle giving choice of multi-position and multi-pole circuits.
...moreInfrared Thermometer
1,000 oC no contact infrared Temp. measurement. 1400 oC type K thermometer. Dual laser for better targeting. Large LCD display with back light. D/S ratio value : 50/1. Min., Max., Differential, Average, Lock mode. Last measurement memory. Hi/Lo Temperature Audio Alarm. Adjustable emissivity value from 0.1 to 1.00. Power supply : DC 1.5V battery (UM 4/AAA) x 2 PCs . Dimension : 203 x 197 x 47 mm
...moreInductive Sensor
Features Light weight Elevated durability Compact design Easy to install
...moreBe first to Rate
Rate ThisOpening Hours