Single Phase Double Wound Transformer
Get Price Quote
ME manufacture L.T Transformers in different types and capabilities to suit individual requirements. These are manufactured both in natural air cooled construction and natural oil cooled construction. In addition to the above other types of transformers are i) Voltage Auto Transformers ii) Current Transformers.These are described in our various leaflets. Special Enquiries will always be entertained with promptness,by our Engineering and sales staff. The transformers described in this catalogue are made in natural air cooled and oil cooled construction, suitable for indoor use in a maximum ambient temperature of 45oC. The electrical performance of these transformers generally confirms to the requirements of I.S. specification No. I.S. 2026 for power Transformers. Natural Air Transformers are supplied in sheet steel ventilated case with screwed top cover. Input and output terminals are provided on the top of the transformer, inside the casing. The transformers are suitable for floor mounting and are also supplied with M.S. rollers for easy portability. Natural oil cooled transformers are supplied in M.S. Tanks. As a standard practice the tank is provided with oil filling hole with cap, oil level indicator drain plug and earthing terminal. Input and Output terminals are brought out generally on the top side of the tank. Extra off-load taps can be provided on request. The capacity of the transformer at the tap will be proportionately low corresponding to the tap voltage. The declared capacity will hold good only for the highest voltages on both input and output, unless the taps are specified as full capacity taps.
Double Wound Transformer
Get Price Quote
We are offering transformer. Double wound, step-down transformer made from high quality annameled dpc copper wire of circular & square cross selection & having crgo lamination as core. Transformer core is cylindrically designed to overcome losses and achieve maximum efficiency high packing fraction enables compact transformer design & reduces heating in high load condition ballast choke is single wound inductor made of crno lamination &anameled copper wire set to perfection to controll current & voltage drop at perticular current load. Setting only possible at factory.
Best Deals from Double Wound Transformer
Double Wound Isolated Variable Transformer
Get Price Quote
Engineers, Scientists, Technicians working in laboratories on sensitive equipment have a need for Isolated mains supply, with a variable output Voltage. This facilitates them in testing various devices demanding different voltages & currents. It is also an Electrical Engineering practice to test devices by applying steadily increasing voltage from 0 V to the device rated voltage. To achieve the above objective, it is normal practice to use a Variable Autotransformer (colloquially known as Variac), followed by a 1: 1 Isolation transformer or vice versa. This combination becomes very bulky & heavy with two separate transformers or even with a combined box. It also occupies much of test bench space. This is more so with increasing current rating or VA. It also loses mobility. Radio Electric Pvt. Ltd. has solved this problem by designing Radiotone Double Wound Isolated Variable Autotransformer (colloquially known as Variac). This elegant & compact arrangement uses only ONE transformer on a single toroidal core. The Radiotone Double Wound Isolated Variable Autotransformer provides 2.5 KV Isolation between primary & secondary, primary & body with a Variable Output Voltage from 0V to the required voltage. Various models of Radiotone Double Wound Isolated Variable Autotransformer (colloquially known as Variac) are as Illustrated in the table. This concept can also be used very effectively in DC power supplies with Variable output (eg. Input 230V / 110 V, Output 0 to 25 V, 5A or 0 to 15V, 8A., etc). We also manufacture table-top models of Radiotone Double Wound Isolated Variable Autotransformer with various types of input/output sockets (Shuko / Dual type / Round type, etc) as required.
Double Wound Isolated Variable Transformer
Get Price Quote
Engineers, Scientists, Technicians working in laboratories on sensitive equipments have a need for Isolated mains supply, with a variable output Voltage. This facilitates them in testing various devices demanding different voltages & currents. It is also an Electrical Engg. practice to test devices by applying steadily increasing voltage from 0 V to the device rated voltage. To achieve the above objective, it is normal practice to use a Variauto followed by a 1: 1 Isolation transformer or vice versa as shown in figure 1. This combination becomes very bulky (heavy) with two separate transformers, wiring or a combined bulky box. occupying much of test test bench space. This is more so as the current rating or VA increasing. It looses its mobility. Radio Electric has solved this problem by designing a "Double Wound Isolated Variable Transformer". This elegant & compact arrangement uses only ONE Transformer on a Single torroidal Core. This provides 2.5 kv Isolation between prim & sec, prim & body with a Variable Output Voltage from 0V to the required voltage. Various models are as Illustrated in table 1.This concept can also be used very effectively in DC power supplies with Variable output (eg. Input 230V / 110 V, Output 0 to 25 V, 5A or 0 to 15V, 8 Amp. etc.). We also manufacture in table-top models with various types of input/output sockets (Shuko / Dual type / Round type, etc.) as required. MODELS Radiotone DW Isolated Variable Transformer I/P 125 V, 60 Hz supply voltage & output Variable from 0 to 150 V
Double Wound Transformer
Get Price Quote
Double Wound Transformer, Oil Immersed Transformer
Double Wound Transformer
Get Price Quote
Double Wound Transformer, horn gap fuse, electric equipments, Dropout Fuse
Double Wound & Auto Wound Transformer
Get Price Quote
Double Wound & Auto Wound Transformer, Copper Carbon Brushes