Drift Eliminator Dealers in Andheri, Mumbai

(4 products available)
  • Drift Eliminator

    Drift Eliminator

    Get Price Quote

    • Material: PVC, PP, FRP
    • Warranty: 1 Year
    • Sheet Spacing: 24mm 20mm
    • Application: Water Treament

    The Purpose Of Drift Eliminator Is To Reduce The Drift Loss In The Cooling Tower. Drift Eliminators Normally Kept Next To Fills In The Air Flow Path Thereby Reducing The Drift Loss. Drift Loss Is The Loss Of Entrained Water Through The Hot Air To Atmosphere. Drift Eliminators Normally Made Up Of Pvc. More Number Of Passes Through Drift Eliminator Decreases The Drift Loss But Increases The Pressure Drop Thereby increasing fan Power Consumption.   The Drift Eliminator Coming In : C Type. S Type. Spectra Type And The Drift Loss Are Coming 0.002 To 0.005%

    more..
  • Double Wall Drift Eliminators

    Double Wall Drift Eliminators

    Get Price Quote

    • Material: Rigid PVC
    • Type Of Structure: Double wall
    • Maximum Face Velocity: 5.0 m/sec
    • Module Length: Up to 3500 mm
    • Module Depth: 146 mm
    • Pitch: 56.5 mm / 66 mm
    • Recommended spacing between supports: 2000 mm
    • Max Recommended Supporting Span: 1830 mm
    • Directional changes for air flow: 3
    • Average Weight: 8.15 kg/m2 / 6.6 kgs/m2
    • Maximum Continuous Temperature (deg Celsius): < 0.002% / 0.05% of circulating water
    • Maximum Continuous Temperature (deg Celsius): 55°C
    more..
  • Best Deals from Drift Eliminator

  • Pvc Drift Eliminator

    Pvc Drift Eliminator

    Get Price Quote

    Drift eliminators are used to capture water droplets in the air stream that otherwise would be lost to the atmosphere. Entrapping these droplets is important for not only conserving water as a resource but also to prevent cooling tower water from contaminating the area peripheral to the cooling tower. The cooling tower industry uses drift rate to compare drift eliminator performance, a relationship that correlates droplet capture efficiency to the water circulation rate in a tower. COOLDECK’s drift eliminators are specifically designed to achieve maximum drift removal efficiency in both crossflow and counterflow tower applications with various product options available to minimize pressure drop, drift loss, cost, or a combination of all three.

    more..
  • Double Wall Drift Eliminators

    Double Wall Drift Eliminators

    Get Price Quote

    We are offering a wide range of Double Wall Drift Eliminators. Drife146, double wall construction is a state-of-the-art drift eliminator that offers best efficiency and performance, is made of specially formulated UV stabilized rigid PVC having superior physical properties. These Double Wall Drift Eliminators are designed removing entrained partides from exhaust air stream efficiently, with minimum pressure drop, thereby reducing the fan energy requirement when the air passes through the drift eliminator. The drifel146 double wall drift eliminator provides dimensional stability and durability, with rugged design & structural integrity for long service usage. These Double Wall Drift Eliminators are superior in practically removing tower drift in an energy efficient way. These can be pressure washed, if necessary, without any damage and can be easily assembled at site allowing span up to 1830 mm. Further, no gluing, no special tools or skilled labor is required. These drift droplets carried in the air stream, when forced to make the three changes in direction in each blade, create centrifugal forces on the drift droplets, forcing them to be captured by impaction and direct interception. Sinusoidal passage forms are widely acknowledged as the most effective design. The flow of carryover water droplets is interrupted as a result of each direction change in these zones. These water droplets are captured on the sidewalls of drife146, they form a film of water that come down the wall via gravity to the drainage channels. This reduces the opportunity for reintrainment. Moreover, no voids or discontinuities exist in the eliminator section. Drife146 double wall drift eliminators have found wide acceptance in the industry and can give a drift loss of less than 0.001% of the circulating water rate, for all droplets larger than 65 microns. We have in-house testing machine to test these products as per ASTM, BIS, DIN, etc. The purpose of testing is to evaluate products to measure the results against the requirements, document the differences and also in order to help in resolving the differences.

    more..
Filter by Locality
top