Durometers
Get Price Quote
Durometer Technical Information The principle used to measure hardness is based on measuring the resistance force of the penetration of a pin into the test material under a known spring load. The amount of penetration (max. 2.54 mm / 0.1 in.) is converted to hardness reading on a scale with 100 units. Whenever possible, a Durometer measurement should be taken at least 12 mm (approx. 0.500") in from the edge of a sample, as the hardness characteristic of any sample tends to change at the edges. Whenever possible, the thickness of a sample should exceed 6 mm (approx. 0.250"). If the sample is thinner then this, then the sample can be backed with a sample of the same material to increase the thickness. Test Coupons or test blocks (rubber or plastic) should not be used for calibration verification. As all samples are subject to characteristic changes over time along with temperature and lighting conditions, the rated Shore value when supplied as new can and will vary with age. Proper calibration verification requires independent confirmation of the internal spring forces along with the verification of the pin displacement vs. the indicated value on the scale. As per the ASTM D2240 Standard, readings below 10 and above 90 are not to be considered reliable and should be discarded. Therefore, it is important to select the approapriate Scale that will provide results between 10-90 units. Frequently Asked Questions "My durometer rests below zero, is it out of calibration?" This is a common question asked by durometer users. The answer to the question, in most cases, is no. This is because the gauges are made in accordance with ASTM D2240 Standard, which states that some durometers have a preload of 56g at a zero reading. Therefore, a durometer giving a less-than-zero reading at rest is not out of calibration.
Hand Held Durometers
Get Price Quote
The Newage® HP Series hand held durometers are ideal for hand held hardness testing of rubber, elastomers and plastic samples. In addition to determining hardness, we also offer models for determining density and elasticity. These precision instruments conform to ASTM D2240. HP durometers are available for A, B, C, D, DO, O and OO scales. HP durometers have a frictionless movement ensuring precision hardness measurement and a circular frustrum cone indenter. A peak indicator is standard on all HP durometers with all measurement indicated on a scale from 0 to 100. Features & Benefits Meets ASTM D2240 Models for Hardness, Density and Elasticity Scales: A, B, C, D, DO, O and OO 1- and 2-point Resolutions Die Cast Aluminum Housing Bavarian Precision Spring Movement Includes Test Block and Carrying Case NIST Certificate of Calibration
Best Deals from Durometers
SUPER DUROMETER
Get Price Quote
Durometer Hardness Tester with extra bottom designed for error free reading and provides limit point for maximum pressing on the specimen. Most suitable hardness tester for Tyres & Tubes and similar type of varous rubber parts.
digital shore durometer
Get Price Quote
digital shore durometer, constant load shore a durometers