water filter systems
Get Price Quote
Water Filter Systems are standard pretreatment systems in the water treatment process, effectively removing a large percentage of suspended solids from your process water by straining it through various media.
Split Unit filter system
Get Price Quote
The Split Unit is designed to save space and is ideal for air conditioned offices and retail outlets where space could be a constraint. This machine’s unique design results in more efficient performance as one part of the unit is installed outside in open air, giving it access to ample fresh air to make water, and the indoor unit dispenses drinking water, thus saving space and reducing noise. The Split unit uses a three stage filtration process and an ozonation process to produce pure drinking water. Features: High efficiency Easy installation Less Occupancy Storage capacity of up to 22 liters (10 liters of purified water+10 liters of collected water+2 liters in split unit)
Best Deals from Filter System
FILTER CLEANING SYSTEM
Get Price Quote
Cleaning of panel filters installed in Air Handling Units & Return air grill have always been a time consuming, cumbersome, messy and manpower intensive process. Further uncontrolled manual cleaning is unreliable and cannot be validated. Further uncontrolled manual cleaning also reduces filter life. Whirlwind filter cleaning stations are designed to clean filters in a closed chamber with controlled compressed air / water. The system is offered in following models. Model FCS-M-I: Filters are cleaned with air & water, cleaning recipe PLC controlled. Suitable forced hot air dryer is provided to dry cleaned & washed filter in controlled enclosure. Model FCS-M-II: Filters are cleaned only with compressed air, cleaning recipe manual with integrated dust control dust collector. Model FCS-M-III: Filters are cleaned only with water forced by multiple Nozzles, cleaning recipe manual and dried in suitable forced hot dryer to dry cleaned and washed filter. Automated system filter movement to and out of cleaning tunnel on conveyor Multiple cleaning head adjusts automatically as per the filter size. PLC controlled cleaning cycle as per recipe of air wash, water wash and dewatering controlled by PLC Optional feature of detergent washing available Adequately sized reverse jet dust collector with final HEPA ensures dust free operation Optional feature of pressure drop across dirty & clean filter offered Hot air Drying chamber with temperature control provided to dry cleaned filters Two filters cleaned at a time Maximum filter size 610x610x305 Filters cleaned by plant compressed Air Cleaning intensity controlled by regulating air pressure , jet and cleaning time. Cleaning recipe controlled by timer Cleaning operation in closed chamber Adequately sized reverse jet dust collector with final HEPA ensures dust free operation Minimum foot print of 1500 x 1800 Optional feature of pressure drop across dirty & clean filter offered BICON LTD - 1 SYSTEM MISSION PHARMA – 2 SYSTEM NEOPHARMA ( DUBAI) 1 SYSTEM PANACEIA BIOTECH LTD- 4 SYSTEMS RANBAXY – 6 SYSTEMS. SANDOZ LTD. – 1 System TORRENT - 2 SYSTEMS TRIDENT - 1 SYSTEM TROIKAA – 1 SYSTEM RANBAXY-CRP- 3SYSTEMS ALKEM LABS – 10 SYSTEMS BENGAL CHEMICALS –M&W/CRP – 2SYSTEMS COLGATE – 3 SYSTEMS USV LTD. – 1 SYSTEM
INDUSTRIAL FILTER SYSTEM
Get Price Quote
FRIENDS AQUA offers wide series of multimedia filters for removal of suspended solids and heavy metals. Filters are available FRP (Fibre Reinforced Polymer), Mild Steel and Stainless Steel. Pressure Sand Filter Pressure Sand Filter is an ideal solution for the systems with high sediment, silt, sand, and turbidity. Our unique design ensures the maximum utilization of the surface area, lesser pressure drop across the pressure bed and effective elimination of the impurities. The strength, stability and micro-porous character of filtration media make sand filter suitable for virtually every application in the water treatment industry. Activated Carbon Filter Activated carbon is the most common method of treatment for de-chlorination and removal of taste and odour from water, through adsorption. Adsorption is directly related to the surface area of the media. Iron removal Filter Iron removal filter is processed catalytic filtration unit where the raw water passes through the layer of compressed air, processed catalyst & quartz filter media respectively. The dissolved ferrous iron salts are converted into insoluble ferric salt and precipitated over the filter bed and then the iron free filtered water comes out. Bromide Removal Filter FRIENDS AQUA offers Bromide removal Filters for various capacity ranging from 10 M3/hr upto 250 M3/hr. Water containing Bromide when ozonated, produces Bromate which is carcinogenic. The level of bromate is allowed upto 20 ppb in Drinking Water. However, FRIENDS AQUA offers systems to reduce Bromide from water to avoid Bromate transformation post Ozonation. The removal is possible up to 5 ppb level. Manganese removal Filter Manganese produces a brownish colour in laundered clothing, leaves black particles on fixtures and as with iron, affects the taste of beverages, including coffee and tea. FRIENDS AQUA specializes in manganese removal systems to help water treatment plants deal with these problems. Specifications: 1. Place of Origin: Mumbai, Maharashtra (INDIA)2. Brand Name: FRIENDS AQUA3. Condition: New4. After-sales Service Provided: YES5. Product name: Industrial Water Filter6. Type: Water Filter Parts7. Certificate: ISO90018. Use: Water Pre-filtration9. Material: 100% Pure Polypropylene; PVDF; PES; N610.OD: 2.5"11.Length: 10'/20"12.ID: 28 MM13.Micron Rate: 0.22, 0.45,1,5,10,25,50,75,100,150 micron
FILTER ULTRASONIC CLEANING WITH ROTATIONS
450,000 Per Piece
1 Piece(s) (MOQ)
Filter length up to 1200 mm or more, 8 to 10 nos at a time with slow rotation of 7 to 10 rpm, high power ultrasonic, rugged & tested system,.
MULTIPLE FILTER HOUSING SYSTEMS
Get Price Quote
The cartridge is of Polypropylene and available form 0.5 to 250 microns. The range of Industrial Non-metallic HousingSystem offers an economical answer to low flow requirements. Non-metallic housings are available in a number of materials of construction to suit a range of chemical applications.
Single and Multiple Filter Housing Systems
Get Price Quote
It was developed by BLINEX FILTER-COAT PVT LTD in 1978 for the first time in India remarkable Single And Multiple Candle Plastic Filter Housing . The cartridge is of Polypropylene and available form 0.5 to 250 microns. The range of Industrial Non-metallic Housing/System offers an economical answer to low flow requirements. Non-metallic housings are available in a number of materials of construction to suit a range of chemical applications. These strong industrial designed housings are ideally suited for use for flows of potable water. The unit is polycarbonate bowl with ABS cap. Properties: Filter the finest suspended particles. The cartridges have uniform pore size, smooth surface, lightweight, odorless, tasteless, non-toxic, resistant to shocks and impacts. The unit withstands the pressure upto 150 PSI. The flow rate form 4 to 15 LPM in different microns cartridge. Typical Application: Air regulators filters Aquarium Aerators Breather vents Marker tip Controlled metering devices Foaming devices Water conditioning filters Pneumatic mufflers Filtration support media Battery flame arrestors ETO vents Chromatography frits Production of defined foams Introduction of oxygen into water Drying Cooling Stripping of solvents Silencing the insulation Diaphragms for electrochemical processes. Application On Various End Uses: Filtration of domestic and industrial water, air, gas, oil, syrups, electroplating and photography solution
CATALYST FILTER SYSTEM
Get Price Quote
CATALYST FILTERS FOR HYDROGENATORS AND AUTOCLAVES Catalyst filtration is an important aspect of a Hydrogenation system. Omega- Kemix supplies a cost effective system, which incorporates. Complete filtration Operational safety Full backwash Minimal holdup of the reaction mass The filter is Fitted with sintered candles Has a special Heel filter Provided with a sight flow indicator Provided with special valves for effective dislodgement of catalyst cake Omega-Kemix make filter has the following advantages Safe procedure for catalyst filtration from the Autoclave There is no spillage of expensive catalyst Closed circuit operation avoids fire hazards in case of pyophoric catalysts High efficiency candles result in very low losses, which are often below measurable limits The filtration system pays for itself through high rate of catalyst recovery CATALYST FILTERS FOR HYDROGENATORS AND AUTOCLAVES: Catalyst filtration is an important aspect of a Hydrogenation system. Omega ‐ Kemix supplies a cost effective system, which incorporates complete filtration, operational safety, full backwash, as well as minimal holdup of the reaction mass. OPERATING PRINCIPLE AND PROCEDURE: At the completion of hydrogenation reaction, balance Hydrogen gas in reactor headspace is vented, and the Reactor is purged with Nitrogen, to eliminate all traces of remaining Hydrogen. Subsequently, the Reactor is pressurized to about 1 bar with Nitrogen, through Valve V1 Valves V2, V3 and V4 are opened. All othe valves (V5 to V8) are in closed position. Nitrogen is continuously fed through Valve V1, so that Reactor pressure is maintained around 1 bar. Typically, if the catalyst is noble metal on a carrier, e.g., Pd/C, the entire mass is filtered. In this case, it is advisable to stir the reaction mass at around 50 RPM, and the dip pipe or blow leg should extend to the lowest possible point in the Reactor. For heavy metal catalysts like Raney Nickel, the bulk of the catalyst settles within a very short time, typically 30 minutes after cessation of stirring. In this case, a common practice is to filter the supernatant liquid (through a dip pipe terminating just below the lower tan line of the Reactor). Nitrogen pressure in the Reactor headspace forces the liquid‐catalyst slurry into the Main Filter through Valve V₃. This filter is fitted with sintered SS 316 L candles, suspended from a tubesheet. These candles also have a 0.2 micron thick vapor deposited Stainless Steel membrane, of the desired micron size, typically 1 to 3 μ. Initially, the Filter body fills up with Liquid‐catalyst slurry. When it is full, filtration commences. Catalyst cake accumulates outside the candles. Clear filtrate enters the candles, and flows out through Valve V4. Filtrate flow can be observed through Sight Flow Indicator (FI). Once the Reactor contents are entirely displaced by Nitrogen, gas will flow into the Filter through V3. The Filter Candles are fitted with an inner Siphon Tube. Gas entering the Filter displaces the slurry, so that clear liquid is siphoned out through Valve V4, due to action of siphon tubes in the candles. Due to this action, slurr level in the Filter falls to the lower end of the candles. In effect, the filter cone and lower parts are full of unfiltered slurry (also known as "Heel"), and candles are coated with wet cake. At this point, only gas flows through the Sight Flow Indicator. A Zero Holdup Filter is fitted at the lower end of the Main Filter, below the conical portion. This is a Jacketed Sintered pipe (or Lower Candle), around 125 mm inside diameter, suitable for inside to outside filtration. The sintered pipe has a similar 0.2 micron thick vapor deposited Stainless Steel membrane on the inside, to facilitate surface filtration. Please refer Drawing 2 for details of the Zero Holdup Filter. When gas flow (i.e., no liquid flow) is observed through the Sight Flow indicator as described above, Valve V4is closed, and V₉ is opened. Nitrogen gas entering the Filter cone forces filtrate through the Lower Candle, so that slurry in the Filter Cone and lower parts is filtered through the Zero Holdup Filter. Heel filtrate is observed flowing through the Sight Flow Indicator FI. Once the entire heel slurry is filtered, no further liquid flow is observed through the Sight Flow Indicator. All the slurry has been filtered. At this stage, outer surfaces of the upper candles, and inner surface of the lower candle are covered with wet cake. Valves V9, V3 and V2 and V1 are now closed, and the Reacto vented to atmospheric pressure, by opening Valve V10. Solvent/feed for the next batch, or Nitrogen at 1 to 5 bar is introduced at Valve V5, located at the top of the Filter. Keeping Valve V10 open, Valve V8 and then Valve V6 is opened, so that catalyst adhering to candle surfaces gets back‐flushed into the Reactor. For best results, Valve V6 should be a Solenoid operated ball valve, so that there is a pressure pulse while opening this valve. This ensures effective dislodgement of catalyst cake from the Candles. This procedure ensures a safe procedure for catalyst filtration from the Autoclave. There is no spillage of expensive catalyst. The closed circuit operation avoids fire hazards, as many catalysts are pyrophoric, and can spontaneously ignite when exposed to air. High efficiency candles result in very low losses, which are often below measurable limits. The filtration system pays for itself. After several batch cycles, it may be necessary to remove catalyst from the system, and send it for disposal or regeneration. In this case, Valve V7 is opened instead of V8, during back flushing operation, and spent catalyst collected in the Recycle Drum.
Micron Filtration System
Get Price Quote
Features: Highly effective Longer working life Easy to install The micron filtration systems are effective in removing contaminants as well as suspended solids a host of liquids. With our product, this process become easy and helps in providing safe drinking water. The potable water is completely free from bad odor, filth and micro-organisms. You can avail it in disposable and washable versions (please contact us for their availability). Micron filtering system is better than reverse osmosis as it removes impurities while sustaining the important minerals. However, RO removes both minerals and impurities. The selection of micron filtration systems can be done on the basis of "purifying capacity". It is also helpful and efficient in removing settle-able solids apart from optimizing the complete particle coagulation. Some of its features are: Lower Operating Cost Water Purity is High Bacterial and Viruses are Removed Fine Particles are also Removed Common Application Areas The top (head) of this micron filtration system has one raw water inlet and one backwash drain. Once the water enters the system, it dispensed with a 'water distribution system'. At its bottom, there is backwash inlet and an outlet for treated water. It is generally used in: Coolant Filtration Food and Beverage Processing Plants Mineral Water Plants Pharmaceuticals Manufacturing Units
Swimming Pools Filters Systems
Get Price Quote
We are engaged in supplying a quality range of pool filtration systems. Offered range of filtration systems offered by us consists of swimming pool filtration system. These systems are manufactured at our vendors sophisticated infrastructure, under the supervision of experienced professionals.
compact filter system
Get Price Quote
compact filter system, community filtration plants, Water Recycling System
filter housing systems
Get Price Quote
filter housing systems, Aerator, stainless steel filter disc, teflon lining
Sparkler Filter System
Get Price Quote
Sparkler Filter System, Packing Conveyor, Bakery Planetary Mixer
water filter system
Get Price Quote
water filter system, Water Purification Systems
filter system
Get Price Quote
filter system
water filter system
Get Price Quote
water filter system, Filtration Equipment, filtration plants
Membrane Filter System
Get Price Quote
Membrane Filter System, Reverse Osmosis Equipment
water filter system
Get Price Quote
water filter system
Membrane Filter System
Get Price Quote
Membrane Filter System, Spectrophotometer - Double Beam
water filter system
Get Price Quote
water filter system