Jay Je-190 (ERTL) Conventional Fire Alarm Panel
Get Price Quote
Features of Products : The panel ranges from 2 to 64 zones. The panel complies with IS 2189 specification. The panel has separate fire and fault indications. The panel also has separate fire and common fault relay. The panel comprises of a 2Amp powe supply unit. Battery backup is provided along with the AC supply. The panel is equipped with a 24VdC piezoelectric buzzer for fault and fire. Technical Specification :INTERNAL POWER SUPPLY UNIT Constant potential battery charger 27.5V DC Adjustable. Output Current limited to 2 A. Low battery voltage monitored at 18 V DC Adjustable. Battery charger monitoring for failure. Mains supply monitoring for failure. Mains supply input voltage range 230V AC + or – 10 %, 50 Hz. Total panel quiescent current 50mA nominal. Approx. Standby time 4.5 Ah Batt. 36 hrs. Battery recharge time from discharge 1 Hr. approx. INTERNAL RELAY CONTACT RATING Fire Relay 5 Amp. S.P. 240 V DC. Common fault relay 5 Amp. S.P. 240 V DC. Aux. Fire relay 5 Amp. S.P. 240 V AC. Panel Indications : System ON Green LED - System normal. Common Fault Amber LED – Internal buzzer will sound intermittently. Common Fire Red LED - Detector activated. Zone fault Amber LED – Indicates zone wiring and detector faults. Zone fire Red LED – indicates zone where fire has been detected. AC fail Amber LED – Indicates loss of mains. DC fail Amber LED – Indicates battery fault. Batt. Low Amber LED – Indicates battery supply below 18V DC External Controls : Sound : To sound external as well as internal sounders. Silence : To silence external as well as internal sounders. Reset : Lamp test & resets the panels. Isolate : The zone to add/clean detectors. Test : International standard walk test.
2 Loop Fire Control System
Get Price Quote
Fret not! We are here to help you out with the payment procedures. Be it online or offline payment method, we are here to assist you all the way through the payment process. We have a capacious warehouse facility that assists us completely in making stock and furnishing varied requirements of the clients. Also, our facility is equipped with modern storage amenities.Standard Features : UL 864 9th Edition listed Multi-Loop 2 Analog Addressable Loops Field upgradable to 4 126 primary points per loop Powerful, network wide cause and effects (500 total). Fully user programmable by point or zone. 800 points per panel when using devices with subpoints Up to 10,000 ft. wiring length on SLC loop 64 Panels on a network Programmable through a PC connection to the panel, or through keypad Programmable relays – 5 Supervised Powered Outputs – 3 Programmable Notification Appliance Circuits - 4 Power per NAC - 1.6 Amps Max Programmable outputs on SLC loop Programmable Function button on front display Fire Drill button on front display Day and night sensitivity settings (user programmable) Power Supply - 5.25 Amp, regulated & integrated LCD Display - 8x40 Zonal Mode - Annunciation by zone w/o individual relationships Panel Ring Modes - Common, Zonal, Stage 2 NAC Outputs programmable as Continuous, March, Temporal Program Cause and Effects AND, OR, or Any Two (Cross Zone) Battery size - Up to 17 Ah in standard enclosure; up to 52 Ah with external cabinet Access levels - 3 Access key switch - Yes Recognized for use in High Rise One man walk test – Fire Test Mode Available with semi flush trim ring Available in Red or Gray Product Overview : The VF1460 and VF1480 analog addressable FACP supports 2 or 4 SLC loops for a total of 500 primary points or 800 points using subpoints. SLC loop communications uses standard twisted pair cabling, shielded cable is not necessary. The panel may be configured with various communication cards; Communications options support central station monitoring, Virtual Panel, and networking. The Panel can be configured as a stand alone panel with just a few devices for a small building, it can also operate as the building system and can be part of a network with a total of 64 nodes serving a multiple building campus or a very large facility. Auto Learn capability provides a convenient method to troubleshoot new installations before final programming is loaded. Added Features : Elite with eNET (VF1465/VF1485) Network uses standard RS485 cabling Up to 2,000 ft. between adjacent panels 115 Kbps constant network speed Secure, fault tolerant communication Up to 64 nodes Elite with DACT (VF1464/VF1484) Dual line digital communicator and modem Contact ID and SIA reporting UL 864 9th edition listed Zone or point reporting Backup and duplicate reporting
Best Deals from Fire Alarm Control Panel
12 To 128 Zones Fire Alarm Control Panel
Get Price Quote
fire control panel
Get Price Quote
With characteristics like unmatched standard and superior grade, our range of product is the finest one obtainable in Mumbai(India). With excellent storage space and shipping facilities, we effortlessly entertain bulk requirements of our respected patrons. We maintain complete records and transactions of the products delivered.
conventional fire alarm panel
10,000 Per Piece
1 Piece(s) (MOQ)
Features of Control Panel : In-built software to sense, receive and recognize the signals sent by the sensors During any abnormal condition or malfunction, an alarm is activated that has to be acknowledged physically and reset Available in 2 to 8 zone (areas) options SMPS power supply Software provided for monitoring and report generation and events logging LED's for individual ZONES to indicate status of respective zones Relay outputs provided for individual Zones Relay output activates in Short / Alarm condition of respective zone Relay output for hooter gets activated, when Short / Alarm condition occurs in any sensors Mute switch provided for silencing the hooter Limit switch for sensing door status (i.e. Open / Close) provided A Buzzer which beeps with hooter in Short / Alarm and Open Panel Door conditions is provided. Here, the buzzer cannot be silenced through Mute key Communication : RS485 serial port at eight baud-rate speed setting (Default 9600 bps) for interfacing with Master (PLC, PC) Optional Potential free outputs for all zones Modbus RTU interface to communicate with BMS System Display : 4x20 LCD for displaying status of all Zones LED Display status for all zones ConvertorRS 485 to RS 232 convertor available at extra costModelsAvailable in 2 Zone to 8 Zone options
Fire Alarm Control Panel
Get Price Quote
We are the leading Manufacturer and Supplier of efficient Fire Alarm Control Panel. The Fire Alarm Control Panel is the Central Monitoring Station where all signals are received and transmitted. It is important that the person responsible for taking action, should know exactly where and what the problem is, as soon as he receives a signal from the panel, given below are the details of how to interpret the various lights and switches on the panel fascia.
Fire Alarm Panel
Get Price Quote
Multi protocol Fire Alarm Control Panel
Get Price Quote
We are offering multi protocol fire alarm control panel. the zx1e is an intelligent fire alarm control panel. It has been designed and constructed around proven and reliable microprocessor technology. This simple approach has produced a modular, scaleable fire alarm platform suitable for protecting all types of premises. The zx1e control panel supports a total of five industry leading protocols, allowing fire detection devices to be independently selected based on performance or aesthetic appeal. The zx series control panels seamlessly integrates with apollo (xplorer, xp95 & discovery), hochiki esp, nittan, morley-ias and system sensor detection device protocols. Designed for maximum flexibility the zx1e control panel is supported by a complete suite of peripherals and software tools. Information on the location of fires, faults and system status can easily be displayed or printed in multiple locations. Integration to voice evacuation systems, paging systems and third party control systems is supported through a range of peripheral interface units. features: multi protocol modular concept simple, robust design intuitive to use easy to maintain easy to expand easy to network easy to install easy to configure
GSM Hybrid Alarm Panel
Get Price Quote
The GSM Hybrid Alarm Panel provided by us efficiently communicates with an extensive range of wired and wireless devices including life protection devices to alarm users before any potential accidents. We only source the products that comply with international quality standards. To get reasonably-priced GSM Hybrid Alarm Panels in timely manner, global buyers can contact us. We are the GSM Hybrid Alarm Panels’ Exporter and Supplier from Mumbai, India. Features : Hybrid alarm panel – 16 wireless & 4 wired zone Built in GSM/GPRS modem for cellular alert You can use your phone as a remote controller Auto dialer – 5 groups – 20 phone numbers maximum SMS – 3 groups – 11 mobile numbers maximum Built-in MIC for audio monitoring & speaker for announcement Dual alarm output 1st for low alarm auto mode & 2nd for high alarm manual activation Voice alert message with location name during panic One stop solution – can be used as an Intrusion, Fire & Medical alarm system Optional integration of 21series DVR & alarm panel enables alarm center function so that you can see before you act Maximum 48 wireless + 4 wired detectors per panel Support rechargeable battery for power backup LED status indicator Built in siren Up to 30minutes delay time for arming Tamper alarm and low battery prompt
Fire alarm panel 2 zone agni
30,000 - 50,000 Per Long Ton
This is good product small office and restaurant
fire fighting control panel
Get Price Quote
Features: Completely automatic in operation except Switching off Diesel Engine driven pump Automatic operation of Main & jockey pumps Diesel Engine panel contains Auto Diesel Engine Starter & Battery charger Audio / Visual Fire alarm when Hydrant goes ON Application: To Automatically control the fire pumps in case of fire situation. It is also incorporated with the Alarm system to maintain all the fire pipe line at set pressure to start DG engines automatically in case electricity failure Specification: Incoming Control & Total Protection with MCCB / MPCB / MCB / SFU / HRC Fuses BAS/BMS related contacts incorporated in the Panel Switchgear from L&T / Schneider Electric / Siemens Control Panels for DOL / Star Delta Motors upto 1000 HP
Fire Alarm Panel
Get Price Quote
Features Rugged CRCA sheet with powder coated finish. Modular Construction. Operates on 230 VAC, 24 VDC. Standby Battery backup with build-in charging. Fire Fault status in unambiguous colored LED. System On, Main, Standby ON status indication. Low Battery visual warning with audible buzzer tone. Earth fault indication with audible buzzer tone. Relay Outputs for actuators. Lamp test facility. One man walk test facility. Zone Isolation facility with loop voltage cut off. Compatible to all types of conventional detectors.
Addressable Fire Alarm Control Panel
Get Price Quote
Features Each loop can connect up to 250 addressable devices. Maximum networking are 32 loops and total addressable points are 8000. Large LCD screen (40 x 15 lines) allows more events to be displayed on the same screen. Loop device can be set up to be temporarily isolated. Individual loop module test feature to save time on panel test. On-board Self-test feature for simulating alarm output. Easy system programming through PC to panel. Events log can store up to 2030 events. Specification optional thermal printer that can printout complete panel status.
conventional fire control panels
Get Price Quote
These conventional fire control panels form part of a comprehensive range of conventional and intelligent fire detection equipment. Compatible products include heat and smoke detectors, sounders and manual call points. The M1, 2 and 4 conventional fire control panels provide one, two and four zones (respectively) of fire detection. All panels have been designed to offer high standards of performance, reliability and quantity and comply fully with BS5839, Part 4, 1988. Each panel provides two alarm warning circuits, a power supply and a battery charger. Three state detector condition monitoring enables both open and short circuit conditions to be monitored and indicated at the panel whilst responding to a fire signal at different level. The system can maintain the operation of manual call points after the removal of detectors. The M1 includes an open collector type common fire output whilst the M2 and M4 feature common fire and fault voltage free, changeover contacts. An enabling security key switch prevents unauthorised operation of the panel controls. FEATURES • Robust, moulded housing and steel back box. • Three state detection with isolate and test facilities on 2 and 4 zone models. • Designed to meet BS5839, Part 4, 1988. • Two fully monitored sounder circuits. • Head removal monitoring with active end of line units included. • Fire and fault relays on 2 and 4 zone models. • Space for 72 hour stand-by batteries. • One cabinet size for all models. SPECIFICATION mechanical Dimensions (HxWxD): 290 x 350 x 89 mm Weight: 4 Kg (9 lbs) Operating temperature: 0°C to +49°C Humidity: 10% to 93% non-condensing electricalOperating voltage: 230 Vac 50Hz Zone voltage: 17 to 28 Vdc Zone quiescent current: 2.4mA Zone End of Line Device: Active End of Line (supplied) Number of Sounder Circuits: 2 - monitored for open and short circuits. Sounder circuit voltage: 17 to 28 Vdc Max. panel sounder circuit current: Single zone: 300mA Two & four zone: 1A Common Fire Output (remote): M1 - open collector M2 - changeover contact M4 - changeover contact Auxillary input: Class change input Standby batteries: Standby hours: 24 Single zone: 1.2Ah Two zone: 1.9Ah Four zone: 2.8Ah Standby hours: 72 Single zone: 2.8Ah Two zone: 7.0Ah Four zone: 7.0Ah
Fire Alarm Panel
Get Price Quote
Cease Fire XT are Supply & Wholesale expertise in domain, offering wide assortment of Fire Alarm Control Panels. These products are suitable for various industries and known for rendering trouble free operations. The offered products are suitable for various applications to meet client's requirements.
Fire Alarm Control Panel
3,500 Per Piece
Fire Alarm Control Panel
Get Price Quote
fire control panel
2,850 Per Piece
2 Piece (MOQ)
Intelligent Fire Alarm Panel
Get Price Quote
Fire Alarm Control Panel
35,500 Per Piece
1 Piece (MOQ)