Fire Hydrant System Spares Dealers in Sion, Mumbai

(17 products available)
  • stand pipes

    stand pipes

    Get Price Quote

    • Features: Reliable, Longevity, Industry proven designs, Fine quality
    more..
  • Fire Hose Valves

    Fire Hose Valves

    Get Price Quote

    • Type: Female*Male,Double female°
    • Test Pressure: 600 psi, 600 psi

    The Hose valve is provided with standard taper pipe threads conform to ANSI B2.1 installation of the hose valve is achieved with readily available field tools, prior to installation, use pipe joint compound or PTFE tape apply on male threads, tighten the hose valve is aligned accordingly to requirement.

    more..
  • Best Deals from Fire Hydrant System Spares

  • Hydrant System

    Hydrant System

    Get Price Quote

    Being one of the oldest but yet the most effective and common fire fighting solution, a well designed and a well laid out hydrant system forms the backbone of the entire fire fighting system. It comprises of heavy duty above & underground piping with accessories. External and fire escape hydrant valves are provided at every strategic location. A fire hydrant is a pipe that allows water to flow from a water main with the control of a valve in order to put out a fire. Fire hydrant protection system is designed to fight fire of huge proportions, in all classes of risks. It is designed to be in operation even if a part of the affected structure collapses. Dry barrel and wet barrel are the two kinds of fire hydrants. The wet barrel fire hydrant holds a constant water supply, while the dry barrel fire hydrant needs to have a valve release to let water in. It is designed to provide rapid access to water in the event that a fire breaks out. Fire brigade connections are installed as standalone systems which act like building-specific fire hydrants, providing fire protection which will be readily available to fire fighters. Guidelines and approval for hydrant system are available from various national and international organizations like: nbc, nfpa, tac, is, fm and local fire authorities. Components of the system: o fire fighting pumps & accessories o piping o panels o landing valves o hoses o couplings o hose reel o branch pipes & nozzles o fire brigade connections o wiring & instrumentations o maintenance valves 

    more..
  • Fire Hose Coupling

    Fire Hose Coupling

    Get Price Quote

    Technical Specfications :- Size: 63mm Material: Gun Metal/Stainless Steel/ Aluminum Alloy Conforming Specification: IS: 903, CM/L No: 8929306 Performance Test: Hydrostatic Test (Body Test): Tested at 21 kgf/cm2 Other Range: 38 mm, 52 mm & 70 mm Hologram: Sticker stuck on Coupling.

    more..
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    • Type: Indoor Fire Hydrant, Outdoor Fire Hydrant, Double Outlet Fire Hydrant
    • Material: Stainless Steel
    • Color: Red
    • Size: 63 MM DIA OUTLET
    • Usage/Application: COMMERCIAL / RESIDENTIAL
    • Flow Rate: 900 LPM
    • Test Pressure: 7 KG/CM2
    • Certification: BIS Approved
    • Water Pressure Required: 7 KG/CM2
    more..
  • fire water monitor

    fire water monitor

    Get Price Quote

    Fire grate, Multisensor Smoke Detector

    more..
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    We offer a range of FIRE HYDRANT SYSTEM and YARD HYDRANTS with all required accessories. Some of the feature of this systems are as follows - HYDRANT SYSTEM The Hydrant System comprises of AC motor driven pump sets with all required accessories including valves, instrumentation and controls etc.  Complete in all respects. An automatic hydrant system is furnished covering the areas completely from independent. Pipe work from  the fire water pump set. The hydrant pipe work is remaining pressurized through the proposed jockey pump taking  care of any leakages in the system pipe lines, valves and fittings. The hydrant system is kept charged by pressurized water at approx. 7 Kg. Cm. Sq. at all  times.  In the event of fire when any of the hydrant valves in the net work is opened,the resultant fall in pressure system is enabling starting the AC MOTOR driven fire water pumping set through pressure switches automatically.  One diesel engine pump shall be standby pump serving hydrant system.  Apart from the automatic starting of the pump sets,provision shall be kept for manual starting also.  Shutting down of the pump sets shall be manual. YARD HYDRANTS Hydrants inside the building is furnished with required accessories such as hose  pipes with instantaneous gun metal couplings and g.m branch pipes located in hose cabinets.  The hose cabinets is wall / column mounting type, constructed out of 18 gauge mild steel sheets. The internal hydrants ( Landing valves) is single headed type taken out from  150/100 mm dia riser through suitable reducer.  The outlets is gun metal and confirm to IS : 5290.  HT Hose reels is firmly held against the wall by suitable heavy brackets and supports.  The hose reel is swinging type ( 180 deg.) and the entire Dum reel etc. is as per IS : 3876.  The rubber tubing is best quality ( Dunlop ) and the nozzle is 6 mm dia. Shut off type.  The equipment shall be out of one of the approved makes. The hydrant main is laid in the form of ring main.  The hydrant risers is terminated with air release valves at the highest points to release the trapped air in the pipe work.

    more..
  • Fire Hydrant System

    Fire Hydrant System

    Get Price Quote

    Our company is looked upon as one of the staggering Fire Hydrant Sprinkler Suppliers in India. The Fire Hydrant System offered by us complies with the international quality standards and are appreciated in the market for its efficiency and reliability. The Water Fire Hydrant System is highly distinguished as no alternative is available in terms of quality and performance. Additionally, customers are eased with the availability of the Fire Hydrant Systems with the salient features as mentioned below: Salient Features It is used mainly in high rise buildings – commercial & residential, industries, chemical plants & oil refineries where fire cannot be fought externally.Water is the best and most basic way of combating fire.The Wet Riser system involves taking pressurized water through the entire building and having outlet like First Aid Hose Reel and Hydrant valve on each floor.This is a statutory requirement for obtaining N.O.C from the Fire Brigade.

    more..
  • Hydrant System

    Get Price Quote

    The hydrant system comprises of ac motor driven pump sets with all required accessories including valves, instrumentation and controls etc. Complete in all respects. An automatic hydrant system is furnished covering the areas completely from independent.

    more..
  • Fire Fighting Pumps

    Get Price Quote

    Fire Protection Systems, fire protection equipments

    more..
  • stand pipes

    Get Price Quote

    stand pipes, PYROPROTECT FIRE HOSE, Double Outlet Type Landing Valve Gunmetal

    more..
  • Fire Hose Reel

    Get Price Quote

    We are offering fire hose reel.

    more..
  • fire fighting pump

    Get Price Quote

    Nozzles, water based sprinkler

    more..
  • fire fighting nozzles

    fire fighting nozzles

    Get Price Quote

    fire fighting nozzles, Adjustable Wrench, Ball Bearings

    more..
  • Fire Hydrant Systems

    Get Price Quote

    Fire Hydrant Systems, fire detection, fire control systems

    more..
  • Super Jet Monitor Nozzle

    Get Price Quote

    Super Jet Monitor Nozzle

    more..
  • hose reel drums

    Get Price Quote

    hose reel drums, carbon dioxide system, storz coupling, wet alarm valve

    more..
Filter by Locality