DS-702 Digital Digiscan Ultrasonic Flaw Detector
Get Price Quote
1 Unit (MOQ)
gas detection system
Get Price Quote
The gas detection controller GMA200continues with the tradition of the company under consideration of innovative technology and trend-setting flexibility. It is designed for commercial and industrial applications for the measurement of combustible and toxic gases as well as for the measurement of oxygen. The compact construction of the GMA200-MW4provides a cost-efficient solution for safe gas monitoring of industrial facilities.Parallel Measurement and flexible applicationUp to four analog and 16 digital transmitters can be connected to GMA200-MW4 and monitored simultaneously.Via the configuration software the measurement range, the measurement designation, the type of transmitter and the type of gas can be set individually as well as three alarm thresholds can be programmed for every connected single transmitter.The microprocessor of the GMA200-MW4 evaluates all receiving signals and activates alarm and relays. In doing so one single gas detection controller GMA200-MW4 can master different gas detection tasks.Integrated RelaysPermanent increasing demands on safety measures require complex gas detection systems and redundant protective measures to protect from gas hazards.Therefore the GMA200-MW4 has six internal relays. For the implementation of safety measures and alarm, four relays can be programmed freely so that in case of alarm the safety measures can be triggered automatically. The programming grants wide-ranged and flexible possibilities like allocation of one or more measurement point s to relay,single alarm per measurement point,configuration of collective alarm and group alarm, error report and voting function. For each, safety related error report and maintenance, one further relay is available.Graphic displayThe clear conception of the controllerGMA200-MW4 allows the rapid recognition of hazardous situations. Current measurement values are shown continuous on the LCD- graphic display.At Alarm a red back light is active.Technical dataMeasuring gases: combustible and toxic gases and vapours, for all GfG transmittersDisplay and control elements: 2,2"-LCD graphic display; 5 button keyboard (left, right, up,down, OK); 13 LEDs for Alarms, operation and Relay statusEnvironmental conditions: for storage:-25..+60°C | 0..99%r.F. (recommended 0...+30°C)for operation: -20..+55°C | 0..99%r.F.Power supply:Operating voltage: 100-240V AC 50-60Hz or/and 24V DC (20-30V DC valid)Power consumption: max.7W (without Transmitter) max.25W (with Transmitter)Fuse: F1=T 500mA (for GMA200-MW4) F2=M 1A (for Transmitter)Transmitter connection:Power supply: 24V DC ±3% with built in power supplyunit, otherwise 20-30VDC (see above) 4x 150mA respectively Itotal=0,6A atany other subdivisionRS485 outputs:TRM-Bus1+2: RS485; Half-Duplex; max. 38400 Baud (only for GMA200-MW4 relay modules)GMA-Bus: RS485; Half-Duplex; galvanically isolated; max. 230400 Baud (for GMA200-MW4 relays modules, control center, PC, SPS or Gateway)Relay Outputs:Contactors: Six Relays with one open contact eachContact current capacity:3A/250V AC or 3A/30V DCAnalog outputs: 2 x analog output4-20mA (burden max.560Ω)free allocatableAlarm acknowledgement inputs: 2 x Reset, free allocatableData logger (optional): 2GB microSD memory card with FAT (FAT16) formattingUSB terminal: Mini USB jack for configuration of the device via PCConnection cable:Cable entries: max. 9 units M16x1,5 (for cable cross section 4,5-10mm)Housing:Protection: IP65Material: PlasticsWeight: ca. 890gDimensions: 209 x 180 x 64mm (W x H x D)Approvals/Testings:Electromagnetic compability: DIN EN 50270:2006Electrical Safety: DIN EN 61010:2010 Additional Information: Item Code: GMA200 Pay Mode Terms: T/T (Bank Transfer),Other Port of Dispatch: Mumbai Packaging Details: One Sensor Per Box
Best Deals from Gas Leak Detector
Uv Flame Detector
Get Price Quote
The HNL Flame Detector is a compact and highly responsive Flame / Fire Detector. The Unit incorporates an extremely sensitive sensing circuit that responds to high energy sources in a bandwidth of 185 – 260 nm with optimum spectral sensitivity centred around 200 nm.Thus HNL Flame Detector is the most effective in early detection of a fire before they can possibly cause damage. In contrast, other types of detectors operate at a disadvantage. Smoke detectors do not operate until the fire has developed into a sufficient size to accelerate smoke along with strata of hot air rising to the detector.It is particularly suitable for use in outdoor applications because it is not affected by wind or rain. Various modelsto detect & control the presence or absence of flame are available.
UV Flame Detector
Get Price Quote
Hdpe Granules, Pvc Resin Powder, san plastic raw material, Pvc Resin
TD 8 Draw Frame
Get Price Quote
Like all Truetzschler draw frames, the TD 8 features computer-controlled direct drives that makes it far more superior to conventional designs that rely on differential and or angular gears and change wheels. The TD 8 also features an improvement over the already reliable 4-over-3 drafting system - an adjustable pressure bar provides controlled guidance of even short fibres. With such high-precision mechanics, the TD 8 ensures optimal control of the fibre flow.
6,9,12 & 33 Zone Walk Through Metal Detector
Get Price Quote
Microprocessor Based Operation, Digitally Controlled, auto tuning, auto setting.Rugged structure , made from ABS sheet, detachable for ease to install & transport, ABS Plastic molded top and shoes, with provision for screwing shoes to ground. Has aluminum strip with polycarbonate strip-insert on both sides for extra strength and high aesthetics.Detects all Metals, Zinc & Metal Alloys, ferrous / non-ferrous metals using single detection program. Test samples as per IS : 14132 : 1992.Indian NABL approved Lab tested, safe for people with pace makers, pregnant woman, digital devises, magnetic media., tested as per ICNIRP guidelines.
Addressable Smoke Detector
1,200 Per Piece
Stand Alone Smoke Detector
4,900 Per number
1 number (MOQ)
Fire Detectors
Get Price Quote
Fire detectors the fuel and ignition; the Fire Triangle is effectively broken. Hence, the fire stops immediately. However,
leak detection machine
Get Price Quote
SHARK 4000 LEX print defect detection system
Get Price Quote
SHARK 4000 LEX, the 100 % print defect detection system for use on rewinders and narrow-web printing machines. It stands out due to its well-engineered technology, extensive range of functions, comprehensive defect management software and features.
Optical Smoke Conventional Detector
Get Price Quote
Our material handling procedure is very well managed by a team of experts and thus we ensure zero damage of the stored products stocked in our capacious warehousing unit. Owing to our reliable transportation amenities, we are capable to deliver the placed orders within the given timeframe and at the right place. The Optical Smoke Conventional Detector, made available by us, is largely acclaimed for its high-quality and reliable performance.
Hand Held Metal Detectors
3,499 Per unit
Smoke Density Detector
5 Per Units
Laser Gas Detector
Get Price Quote
We are dealing best laser-gas-detector supplying company.
magnetic crack detector
Get Price Quote
wireless digital fire detector
Get Price Quote
wireless digital fire detector
Door Frame Metal Detector
35,000 Per Piece
Door Frame Metal Detector
Get Price Quote
Hdpe Granules, Rubber Wood Pallet, HDPE Films, hessian
Smoke Detector Camera
Get Price Quote
Smoke Detector Camera, Indoor Omni Antenna, Patch Panel Antenna